• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA30-0AJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA30-0AJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA30-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA30-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, offering a compact and integrated solution for process visualization and machine control.

    The SIMATIC Panel PC 670 (6AV7611-0AA30-0AJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and runs Microsoft Windows operating systems, enabling compatibility with standard SCADA and HMI software such as WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and supports expansion via PCI slots. It is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI solution is required. It is suitable for applications such as supervisory control, data acquisition, recipe management, and complex visualization tasks that demand the flexibility of a Windows-based PC platform. Industries such as automotive, food and beverage, chemical processing, and packaging commonly deploy this panel PC for operator station and visualization server roles.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Mounting Front panel mounting
    Operating System Microsoft Windows XP / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image if necessary.
    Event ID: 1000
    Application crash — the HMI or SCADA application (e.g. WinCC) has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the HMI software. Check for memory or hardware faults.
    Event ID: 7026
    Driver load failure — a hardware driver failed to load during Windows startup, potentially affecting communication interfaces or display output.
    Check Device Manager for driver conflicts. Reinstall the appropriate driver from the Siemens recovery image or driver package.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation system via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check PLC communication settings and ensure the correct communication driver is configured in the HMI software.
    Watchdog Timeout
    The system watchdog has detected that the application or operating system has become unresponsive and has triggered a reset.
    Investigate the cause of the application hang. Check CPU load, memory usage, and application logs. Update or repair the HMI application if necessary.
    Fan Failure Warning
    The internal cooling fan has stopped or is operating below the required speed, risking overheating of the Panel PC.
    Inspect and clean the fan and ventilation slots. Replace the internal fan if it is defective. Ensure ambient temperature is within specification.
    Hard Disk Error
    The internal hard disk drive is reporting read/write errors or has failed, which may cause system instability or data loss.
    Run a disk diagnostic utility. Back up data immediately if possible. Replace the hard disk drive and restore the operating system image.
    Display Backlight Failure
    The LCD backlight has failed or degraded significantly, resulting in a dim or completely dark display despite the system running normally.
    Replace the backlight inverter board or the LCD panel assembly. Verify the backlight power connector is securely seated.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AA30-0AJ0?

    The SIMATIC Panel PC 670 (6AV7611-0AA30-0AJ0) operates on a 24 V DC supply voltage.

    What display size and resolution does this Panel PC have?

    This unit features a 12-inch TFT color LCD with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen.

    What operating system does the 6AV7611-0AA30-0AJ0 support?

    The SIMATIC Panel PC 670 supports Microsoft Windows XP and Windows 2000, and is compatible with Siemens WinCC and other standard PC-based HMI software packages.

    What is the front panel protection rating of this Panel PC?

    The front panel of the 6AV7611-0AA30-0AJ0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.

    What communication interfaces are available on this unit?

    The Panel PC 670 provides Ethernet (RJ45), RS-232, and RS-422/485 serial communication interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check that the 24 V DC supply is present and within tolerance at the power input connector. Verify that the backlight inverter is receiving power and that the LCD panel cable is securely connected internally.

    Replace the backlight inverter board if no backlight is present but the system is otherwise running. If the display shows no image at all, reseat the display cable or replace the LCD panel assembly.

    Panel PC fails to boot and shows a black screen or BIOS error

    Inspect the internal hard disk or CompactFlash storage device for physical damage or connection issues. Attempt to enter the BIOS setup to verify that the boot device is detected.

    Replace the hard disk or CompactFlash card and restore the factory operating system image using the Siemens recovery media. Reseat all internal connectors if the storage device is not detected.

    Touch screen does not respond or registers incorrect touch positions

    Check whether the touch controller driver is loaded correctly in Windows Device Manager. Verify that the touch screen surface is clean and free from damage or contamination.

    Recalibrate the touch screen using the Windows touch calibration utility. If calibration does not resolve the issue, replace the touch screen overlay or the touch controller board.

    Loss of communication with PLC or network devices

    Verify the Ethernet cable connection and check the IP address configuration in Windows Network Settings. Confirm that the PLC communication driver and project settings in the HMI software are correctly configured.

    Replace the Ethernet cable if faulty. Reset the IP address configuration to match the network requirements. Reinstall the communication driver if it is missing or corrupted in Device Manager.

    System runs slowly or HMI application freezes intermittently

    Check CPU and memory utilization in Windows Task Manager. Inspect the hard disk for errors using a diagnostic tool, as a failing disk can cause severe performance degradation.

    Free up disk space and disable unnecessary startup programs. Replace the hard disk if errors are detected. Increase virtual memory settings if RAM is insufficient for the application requirements.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart