• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA30-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA30-0AE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA30-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA30-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, providing a compact and integrated solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7611-0AA30-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. It runs on a standard x86-compatible processor platform and supports Windows-based operating systems, enabling compatibility with standard SCADA and HMI software packages such as WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and is built to withstand industrial environments with an IP65-rated front panel for protection against dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design options make it suitable for continuous operation in production lines, packaging machinery, and process control cabinets. The panel PC format allows direct integration into control panels, reducing installation space and cabling complexity compared to separate PC and display setups.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Front Panel Protection IP65
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP / Windows 2000 compatible

    Common Error Codes & System Events

    Event ID: 1001
    Operating system startup failure — the Panel PC fails to boot into the configured OS, often due to a corrupted system partition or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Restore the system image from backup using the recovery partition or an external recovery medium.
    Event ID: 1002
    Hardware watchdog timeout — the system watchdog has triggered a reset due to an application or OS hang.
    Investigate the running application for deadlocks or resource exhaustion. Update or reinstall the HMI software. Check CPU and memory utilization.
    Event ID: 1003
    24 V DC supply undervoltage — the panel PC has detected that the supply voltage has dropped below the acceptable threshold.
    Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated for the panel PC load and check wiring for voltage drop.
    Event ID: 1004
    Touchscreen calibration error — the touch input is misaligned or unresponsive after a system restart or OS reinstallation.
    Run the touchscreen calibration utility from the Windows Control Panel or the SIMATIC touchscreen driver settings. Recalibrate using a stylus for accuracy.
    Event ID: 1005
    Ethernet communication loss — the panel PC has lost network connectivity to the PLC or SCADA server.
    Check Ethernet cable integrity and switch/hub connectivity. Verify IP address configuration and subnet settings. Restart the network adapter via Device Manager if necessary.
    Event ID: 1006
    Storage medium failure — the CompactFlash card or hard disk is reporting read/write errors or is not detected at POST.
    Replace the CompactFlash card or hard disk with a compatible unit. Restore the system image from a backup. Ensure the replacement medium meets Siemens specifications for the Panel PC 670.
    Event ID: 1007
    Fan failure or overtemperature warning — internal temperature has exceeded the operating threshold, or a cooling fan has stopped functioning.
    Check and clean any ventilation openings. Verify ambient temperature is within the 0–50 °C operating range. Replace the cooling fan if it has failed.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AA30-0AE0?

    The SIMATIC Panel PC 670 (6AV7611-0AA30-0AE0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.

    What operating system does the 6AV7611-0AA30-0AE0 support?

    This Panel PC supports Windows XP Embedded and Windows 2000 operating systems. It is compatible with Siemens WinCC and other standard SCADA/HMI software packages designed for x86 Windows platforms.

    What is the front panel protection rating of this panel PC?

    The front panel of the 6AV7611-0AA30-0AE0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for use in industrial panel installations.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces, allowing connectivity to PLCs, SCADA systems, and other industrial devices.

    Can the storage medium on this Panel PC be replaced?

    Yes, the SIMATIC Panel PC 670 uses a CompactFlash card or hard disk as its storage medium, both of which are field-replaceable. Siemens recommends restoring the factory system image after replacement.

    Troubleshooting

    Display remains blank after power is applied

    Check that the 24 V DC supply voltage is present at the power connector using a multimeter. Verify that the power LED indicator is illuminated. Inspect internal fuses if accessible.

    Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may have failed and should be replaced or sent for repair.

    Touchscreen does not respond or responds inaccurately

    Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate the touchscreen through the Windows Control Panel. Check the touchscreen controller connection internally.

    Recalibrate the touchscreen using the Siemens touchscreen calibration utility. If recalibration does not resolve the issue, replace the touchscreen overlay or the touchscreen controller board.

    Panel PC fails to boot and displays a POST error or blank screen after BIOS

    Check the CompactFlash card or hard disk for physical damage or loose seating. Attempt to boot from an external recovery medium to determine if the storage device has failed.

    Reseat or replace the CompactFlash card or hard disk. Restore the operating system image from the Siemens recovery backup. If the motherboard fails POST entirely, the main board may require replacement.

    Ethernet communication is intermittent or not established

    Verify the Ethernet cable and switch port are functioning by testing with a known-good cable. Check the IP address and subnet configuration within Windows Network Settings. Observe the link LEDs on the RJ45 port.

    Replace the Ethernet cable if faulty. Reconfigure the network settings to match the plant network. Update or reinstall the Ethernet adapter driver if the interface is not recognized by the operating system.

    System freezes or restarts unexpectedly during operation

    Check the system event log in Windows for hardware watchdog events or application crash reports. Monitor CPU temperature and verify that ventilation openings are not blocked.

    Clean ventilation openings and ensure ambient temperature is within the 0–50 °C operating range. If software-related, update or reinstall the HMI application. If hardware-related, the main board or RAM module may need to be inspected and replaced.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart