Siemens 6AV7611-0AA22-0CJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA22-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7611-0AA22-0CJ0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing compatibility with SIMATIC WinCC and other Siemens SCADA/HMI software. The unit includes standard PC interfaces such as USB, serial (RS-232), and Ethernet ports, and is designed for front-panel mounting with an IP65 protection rating on the front face.
This Panel PC is widely used in manufacturing, process industries, and machine automation where a full PC-based HMI platform is required. Its rugged industrial design makes it suitable for installation in control cabinets and operator panels in environments such as automotive production, chemical processing, and food and beverage manufacturing. The ability to run standard Windows-based software makes it a flexible platform for custom visualization and data acquisition applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Processor | Intel Celeron |
| Mounting | Panel mounting (front flush) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC failed to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image using the Siemens recovery medium. - Event ID: 200
- Touchscreen calibration error — the touch input is misaligned or unresponsive after startup.
Run the touchscreen calibration utility from the Windows Control Panel or the SIMATIC configuration tool. If unresponsive, check the touch controller cable connection internally. - Event ID: 300
- Ethernet communication failure — the Panel PC cannot establish a network connection to the PLC or SCADA server.
Verify Ethernet cable integrity and switch port status. Check IP address configuration and ensure the correct network adapter driver is installed. - Event ID: 400
- WinCC Runtime startup error — the HMI visualization software fails to launch or crashes on startup.
Check the WinCC project configuration for errors. Verify that the correct runtime license is installed and that the project files are not corrupted. - Event ID: 500
- Fan failure warning — the internal cooling fan has stopped or is operating below the required speed threshold.
Inspect and clean the fan and ventilation slots. Replace the internal fan if it is defective to prevent thermal shutdown. - Event ID: 600
- Hard disk or storage medium error — read/write errors detected on the internal storage device.
Run a disk check utility (chkdsk) to identify and repair file system errors. Replace the hard disk or CompactFlash card if hardware failure is confirmed. - Event ID: 700
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 6AV7611-0AA22-0CJ0?
This Panel PC supports Microsoft Windows XP Professional and Windows 2000, which are pre-installed or available as factory options. It is compatible with Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software.
What is the display size and resolution of this unit?
The 6AV7611-0AA22-0CJ0 features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA). It includes a resistive touchscreen for operator input.
What is the supply voltage requirement for this Panel PC?
The unit requires a 24 V DC power supply. Ensure the power source is stable and within the specified voltage tolerance to prevent operational faults.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and other PC-based HMI software. The appropriate WinCC runtime license must be installed separately.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AA22-0CJ0 carries an IP65 protection rating, making it resistant to dust and water jets. The rear of the unit is rated IP20.
Troubleshooting
Display remains blank after power is applied
Check that the 24 V DC supply voltage is present and within tolerance at the power input connector. Verify that the power LED indicator is illuminated.
If supply voltage is correct but display remains blank, check the internal backlight inverter and backlight lamp. Replace the backlight or the display assembly if the inverter output voltage is absent.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen using the Windows Control Panel calibration utility. Check for physical damage or contamination on the screen surface.
Recalibrate the touch controller. If the issue persists, inspect the internal ribbon cable connecting the touch panel to the controller board and reseat or replace it as necessary.
Panel PC fails to boot and displays a black screen or BIOS error
Check the internal CompactFlash card or hard disk for secure seating and physical damage. Attempt to boot from an external recovery medium.
Reseat the storage medium. If the operating system is corrupted, restore it using the Siemens factory recovery image. Replace the storage device if hardware failure is confirmed.
Ethernet connection is not established or is intermittent
Verify the Ethernet cable and switch port. Check the Windows Device Manager for network adapter errors and confirm the IP address configuration is correct.
Replace the Ethernet cable if damaged. Reinstall the network adapter driver if it shows an error in Device Manager. Check and correct the IP settings to match the network configuration.
Unit shuts down unexpectedly or displays overtemperature warnings
Check the ambient temperature around the unit and ensure ventilation slots are not blocked. Inspect the internal cooling fan for operation.
Clean the ventilation slots and fan of dust buildup. Ensure the installation environment does not exceed 45 degrees C. Replace the internal cooling fan if it is not spinning.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page