Siemens 6AV7611-0AA30-0AF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA30-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single front-panel-mountable device, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AA30-0AF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard industrial communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with PLCs and field devices. The fanless or fan-cooled design options and the use of industrial-grade components contribute to reliable long-term operation in harsh environments.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process industries, and machine building where a full PC-based HMI platform is required. It is suitable for applications in automotive production lines, chemical and pharmaceutical plants, food and beverage processing, and water treatment facilities. Its compatibility with the SIMATIC software ecosystem makes it a natural fit for installations using Siemens S7 PLCs and TIA Portal-based engineering environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Communication Interface | Ethernet (RJ45), USB, RS-232/RS-422/RS-485 |
| Operating System | Windows XP / Windows 2000 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
Check the hard disk or CompactFlash card for errors. Restore the system image using the recovery partition or replace the storage medium if faulty. - Event ID: 1000
- Application fault — the HMI or SCADA application (e.g. WinCC) has crashed unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall or repair the HMI software. Check for software compatibility with the installed OS version. - Event ID: 7000
- Service failed to start — a required Windows service did not start during boot, which may prevent HMI communication or display functions.
Check the Windows Event Viewer for the specific service name. Ensure all required services are set to automatic startup and restart the Panel PC. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or field device.
Verify Ethernet or serial cable connections. Check IP address configuration and network settings. Confirm the PLC is powered and running. Restart the communication driver in WinCC. - Hardware Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
Investigate the cause of the system hang — check CPU load, memory usage, and running processes. Update or reinstall drivers and HMI software. Replace hardware if the issue persists. - Fan Failure Warning
- The internal cooling fan has failed or is operating below the required speed threshold, risking overheating.
Power down the unit and inspect or replace the internal fan. Ensure ventilation slots are not blocked. Check ambient temperature is within specification. - Battery Low Warning
- The CMOS/RTC backup battery voltage is low, which may cause loss of BIOS settings and system time after power loss.
Replace the internal CMOS battery (typically CR2032 or equivalent). After replacement, re-enter BIOS settings and synchronize the system clock. - Display Backlight Failure
- The LCD backlight has failed or degraded significantly, resulting in a dim or completely dark display.
Replace the CCFL backlight lamp or the inverter board. If the display assembly is sealed, replace the complete display unit.
Frequently Asked Questions
What operating systems are supported by the 6AV7611-0AA30-0AF0?
The SIMATIC Panel PC 670 (6AV7611-0AA30-0AF0) supports Microsoft Windows XP Professional and Windows 2000, which are the operating systems compatible with the hardware generation of this unit.
Is the 6AV7611-0AA30-0AF0 compatible with Siemens WinCC?
Yes, this Panel PC is designed to run SIMATIC WinCC and other Siemens HMI software packages. Compatibility depends on the WinCC version and the installed operating system version.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AA30-0AF0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel mounting.
What communication interfaces are available on this unit?
The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), allowing connection to PLCs, field devices, and peripheral equipment.
Can the storage medium on this Panel PC be replaced or upgraded?
The SIMATIC Panel PC 670 uses a hard disk drive or CompactFlash card as its storage medium, depending on the configuration. The storage medium can be replaced, and a system image must be restored after replacement using the Siemens recovery tools.
Troubleshooting
Display remains blank after power on
Check that 24 V DC supply voltage is present at the power connector. Verify the backlight inverter is functioning by listening for a faint high-frequency tone. Measure voltage at the inverter board input.
If supply voltage is correct but display is dark, replace the backlight lamp or inverter board. If no supply voltage is present, check the external power supply and wiring. Replace the internal power supply board if the unit receives power but produces no output.
Panel PC fails to boot into Windows
Observe the boot sequence on the display. If the BIOS POST screen appears but Windows does not load, the issue is likely a corrupted OS installation or a failed storage device. Run a disk check utility from the BIOS or recovery environment.
Restore the factory system image using the Siemens recovery partition or a recovery CD/USB. If the hard disk or CompactFlash card has failed, replace it with a compatible unit and restore the system image.
Touch screen does not respond or is misaligned
Check if the touch controller driver is loaded correctly in Windows Device Manager. Attempt to recalibrate the touch screen using the Windows calibration utility or the Siemens touch calibration tool.
Recalibrate the touch screen through the control panel. If the touch screen remains unresponsive, check the ribbon cable connection between the touch panel and the controller board. Replace the touch screen overlay or controller board if the fault persists.
Loss of communication with connected PLC
Verify the Ethernet or serial cable is securely connected at both ends. Check the IP address configuration on the Panel PC matches the network settings. Use a ping test to confirm network connectivity to the PLC.
Correct any IP address or subnet mask mismatches. Replace the communication cable if damaged. Restart the WinCC communication driver or the entire HMI application. If using a serial interface, verify baud rate, parity, and stop bit settings match the PLC configuration.
System time resets to default after each power cycle
This indicates the CMOS backup battery is depleted. Enter the BIOS setup after power-on to confirm the time is not retained between power cycles.
Replace the internal CMOS battery with the correct type (typically CR2032). After replacement, set the correct date and time in the BIOS and save the settings before booting into Windows.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page