• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA12-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA12-0CE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA12-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA12-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface applications, combining computing power with a robust industrial enclosure. This unit integrates a flat-panel display with an embedded PC platform, providing a compact all-in-one solution for visualization and control tasks.

    The SIMATIC Panel PC 670 (6AV7611-0AA12-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors. It is based on an x86-compatible processor architecture and supports standard PC interfaces including USB, serial (RS-232), and parallel ports, as well as Ethernet connectivity for integration into industrial networks. The unit is designed to run Windows-based operating systems and supports SIMATIC WinCC and other SCADA/HMI software packages. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, panel-mounted computing platform is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a versatile platform for both visualization and data acquisition tasks.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Operating System Support Windows XP, Windows 2000
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat memory modules. Replace storage medium if corrupted.
    Event ID: 200
    Watchdog timeout triggered, indicating the application or OS has stopped responding.
    Restart the panel PC. Check the running application for software loops or memory leaks. Update or reinstall the HMI software if the issue persists.
    Event ID: 300
    Ethernet communication link failure or network connection lost.
    Check Ethernet cable and connector integrity. Verify network switch port status and IP configuration settings in the operating system.
    Event ID: 400
    Undervoltage detected on the 24 V DC supply input.
    Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
    Event ID: 500
    Fan failure or thermal warning — internal temperature exceeding operating threshold.
    Check and clean ventilation openings. Verify fan operation. Ensure ambient temperature is within the 0 °C to +45 °C operating range.
    Event ID: 600
    Touchscreen or display interface fault — no touch input detected.
    Recalibrate the touchscreen via the operating system control panel. Check the internal ribbon cable connection between the display and the motherboard.
    Event ID: 700
    Hard disk or CompactFlash storage device not detected or read error.
    Reseat the storage device. Check for file system corruption using OS diagnostic tools. Replace the storage medium if hardware failure is confirmed.
    Event ID: 800
    USB device error or unrecognized peripheral connected to USB port.
    Disconnect and reconnect the USB device. Verify driver installation in the operating system. Test with a known-good USB device to isolate the fault.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AA12-0CE0?

    The SIMATIC Panel PC 670 (6AV7611-0AA12-0CE0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.

    What display size and resolution does this Panel PC have?

    This unit features a 12-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.

    What is the front panel protection rating of the 6AV7611-0AA12-0CE0?

    The front panel of the SIMATIC Panel PC 670 meets IP65 protection, providing full dust protection and resistance to water jets from any direction.

    Is this Panel PC compatible with Siemens WinCC HMI software?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other standard PC-based HMI and SCADA software packages running on Windows operating systems.

    What communication interfaces are available on this unit?

    The 6AV7611-0AA12-0CE0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel interfaces for connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector using a multimeter. Check for blown internal fuses or a faulty power supply unit.

    Ensure the supply voltage is stable at 24 V DC within tolerance. Replace any blown fuses. If the internal power supply module is faulty, replace or have it repaired by a qualified technician.

    Display is blank or shows no image after power on

    Check whether the PC is booting by listening for hard disk activity or connecting an external monitor if supported. Verify the display backlight is functioning by shining a light on the screen surface.

    Replace the backlight inverter or CCFL backlight lamp if the backlight has failed. If the display panel itself is faulty, replace the TFT display assembly. Check the internal display cable connections.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt touchscreen recalibration through the Windows control panel or SIMATIC touchscreen calibration utility. Check for physical damage or contamination on the screen surface.

    Recalibrate the touchscreen. Clean the screen surface with a soft, dry cloth. If calibration fails repeatedly, check the internal touchscreen controller cable connection or replace the touchscreen overlay.

    Unit freezes or reboots unexpectedly during operation

    Check the operating temperature of the installation environment. Review Windows event logs for application errors or hardware faults. Monitor CPU and memory usage for resource exhaustion.

    Ensure ambient temperature is within 0 °C to +45 °C and ventilation openings are unobstructed. Update or reinstall the HMI application. If hardware faults are logged, reseat memory modules or replace the storage medium.

    Ethernet communication is not established with the PLC or network

    Verify the Ethernet cable is properly connected and the link LED on the RJ45 port is illuminated. Check the IP address configuration in the Windows network settings.

    Replace the Ethernet cable if damaged. Configure the correct IP address, subnet mask, and gateway settings. Check the network switch port and ensure the PLC communication settings match the Panel PC configuration.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart