Siemens 6AV7611-0AA12-0BJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA12-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, offering a compact and integrated solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AA12-0BJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), and parallel ports, along with an Ethernet interface for network connectivity. It is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI solution is required. It is suitable for applications such as SCADA visualization, production line monitoring, and integration with Siemens SIMATIC S7 PLC systems via PROFIBUS or Ethernet. Its rugged industrial design and compatibility with standard automation software make it a practical choice for both new installations and system upgrades in factory automation environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Front panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the operating system or HMI runtime software has caused an unexpected termination.
Check Windows Event Viewer for details. Reinstall or repair the HMI runtime software (e.g. WinCC flexible). Verify software version compatibility. - Event ID: 7000
- A system service failed to start during Windows boot sequence.
Check Windows Event Viewer under System logs. Verify that all required services for the HMI application are enabled and set to automatic start. - BIOS POST Error
- Hardware component not detected or failed during Power-On Self-Test, preventing normal boot.
Reseat RAM modules and any expansion cards. Check hard disk or CompactFlash connection. If persistent, replace the faulty hardware component. - WinCC Runtime Error
- WinCC or WinCC flexible runtime fails to start or crashes during operation due to a corrupted project or missing license.
Verify the WinCC license is valid and installed. Reload the HMI project from the engineering station. Reinstall the runtime software if corruption is suspected. - Communication Error
- Loss of communication between the Panel PC and the connected PLC (e.g. SIMATIC S7) via Ethernet or PROFIBUS.
Check physical cable connections and network settings. Verify IP address configuration and PLC connection parameters in the HMI project. Check PLC operational status. - Hard Disk Failure
- The internal hard disk or storage medium is not detected or reports read/write errors, causing system instability or failure to boot.
Replace the internal hard disk or CompactFlash card with a compatible unit. Restore the operating system and HMI project from a backup image. - Watchdog Timeout
- The system watchdog timer has triggered a reset due to the operating system or application becoming unresponsive.
Investigate CPU load and running processes. Check for software loops or memory leaks in the HMI application. Update or reinstall the runtime software.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AA12-0BJ0?
The SIMATIC Panel PC 670 (6AV7611-0AA12-0BJ0) operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices.
What HMI software is compatible with this Panel PC?
This unit is compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software packages. It runs a Windows-based operating system (Windows XP or Windows 2000), allowing installation of standard PC-based SCADA and visualization software.
What is the front panel protection rating of this device?
The front panel of the 6AV7611-0AA12-0BJ0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Can this Panel PC communicate with SIMATIC S7 PLCs?
Yes, the Panel PC 670 can communicate with SIMATIC S7-300 and S7-400 PLCs via Ethernet (TCP/IP) or PROFIBUS, using the appropriate communication drivers within the WinCC runtime environment.
What display size and resolution does this unit have?
The 6AV7611-0AA12-0BJ0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 64,000 colors.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage level. Check internal fuses on the power supply board.
Replace any blown internal fuses with the correct rating. If the power supply board is faulty, replace the internal power supply module. Verify that the 24 V DC source can supply sufficient current.
Display is blank or backlight does not illuminate after power on
Confirm the unit is powering on by listening for fan activity or checking indicator LEDs. Test the backlight inverter board and the CCFL backlight lamp for continuity and function.
Replace the CCFL backlight lamp or the inverter board if faulty. If the display panel itself is damaged, replace the TFT display assembly with a compatible 12-inch unit.
Touchscreen does not respond or registers incorrect touch positions
Check the touchscreen controller connection to the motherboard. Verify that the touchscreen calibration utility has been run within the Windows operating system.
Recalibrate the touchscreen using the Windows calibration tool. If calibration does not resolve the issue, replace the touchscreen overlay and re-run calibration.
System fails to boot and displays a hard disk error or missing operating system message
Enter the BIOS setup to verify that the hard disk or CompactFlash storage is detected. Check the data and power cable connections to the storage device.
Reseat the storage device connections. If the hard disk is faulty, replace it with a compatible unit and restore the operating system and HMI project from a backup image.
Loss of communication with PLC during operation
Check the Ethernet or PROFIBUS cable connections at both the Panel PC and the PLC. Verify the IP address and network configuration settings in the HMI project match the PLC configuration.
Replace damaged cables and reseat connectors. Correct any IP address conflicts or misconfigured communication parameters in the WinCC project. Restart both the Panel PC and the PLC if necessary.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page