
Siemens 6AV7611-0AA10-0CE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA10-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization applications in automation environments. This unit integrates computing hardware and a flat-panel display into a single compact housing suitable for direct panel installation.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a touch-sensitive screen for operator interaction. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, enabling integration with PLCs and higher-level SCADA systems. It is designed for 24 V DC supply and is built to meet industrial environmental standards including vibration and EMC requirements.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a robust, panel-integrated PC-based HMI solution is required. It is suitable for applications such as production line visualization, process monitoring, and data acquisition in sectors including automotive, food and beverage, chemical, and general industrial manufacturing. Its fanless or low-maintenance design options make it appropriate for environments where reliability and long service intervals are critical.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, RS-232/RS-422/RS-485 (serial) |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cUL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100000
- General system startup error during boot sequence, typically related to hardware initialization failure.
Check power supply voltage at 24 V DC input. Verify all internal connections and reseat RAM modules if accessible. Restore BIOS defaults if system fails to POST. - Event ID: 110000
- Operating system boot failure or corrupted system partition detected.
Boot from recovery media and restore the system image. Check the hard disk or CompactFlash card for errors using diagnostic tools. - Event ID: 120000
- WinCC Runtime communication error — loss of connection to the PLC or controller.
Verify Ethernet cable connections and network configuration. Check PLC availability and confirm correct IP addressing in WinCC project settings. - Event ID: 130000
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. If persistent, inspect the touch controller hardware. - Event ID: 140000
- Hardware watchdog timeout — system did not respond within the expected time window.
Investigate CPU load and running processes. Reduce background tasks or increase watchdog timeout settings. If recurring, check for hardware faults. - Event ID: 150000
- Fan failure or thermal warning — internal temperature exceeding operating threshold.
Check ventilation around the panel PC. Clean any air filters or vents. Verify fan operation if unit is fan-cooled. Ensure ambient temperature is within specification. - Event ID: 160000
- Storage medium error — read/write failure on hard disk or CompactFlash storage device.
Run disk diagnostics. Replace the hard disk or CompactFlash card if errors are confirmed. Restore system image from backup after replacement. - Event ID: 170000
- USB device error or unrecognized peripheral connected to USB port.
Disconnect and reconnect the USB device. Verify device compatibility with the installed operating system. Update or reinstall USB drivers if necessary.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7611-0AA10-0CE0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.
What HMI software is compatible with this Panel PC?
The SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other PC-based HMI and SCADA software packages running on Windows operating systems.
What is the display size and resolution of this unit?
The 6AV7611-0AA10-0CE0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).
What is the front panel protection rating?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installation.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the unit supports Ethernet-based communication and can connect to Siemens S7-300, S7-400, and S7-1500 PLCs using standard PROFINET or Industrial Ethernet protocols via WinCC or Step 7 software.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the input connector. Check the internal fuse and verify the power LED status on the unit.
Restore correct supply voltage within the 24 V DC specification. Replace the internal fuse if blown. If the backlight is faulty, the display assembly or inverter board may require replacement.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen through the Windows control panel. Check for physical damage or contamination on the screen surface.
Perform a touchscreen recalibration using the SIMATIC calibration tool or Windows Tablet PC settings. Clean the screen surface. If calibration fails repeatedly, replace the touch controller or touchscreen assembly.
Unit fails to boot or continuously restarts
Observe the boot sequence for error messages. Check the hard disk or CompactFlash storage device for errors using BIOS diagnostics or an external diagnostic tool.
Restore the system image from a backup using recovery media. Replace the storage device if hardware errors are confirmed. Verify BIOS settings are correctly configured for the installed storage type.
Loss of communication with PLC or SCADA system
Check Ethernet cable integrity and switch/hub connectivity. Verify IP address configuration in WinCC and confirm the PLC is online and reachable via ping.
Replace faulty Ethernet cables or network components. Correct IP addressing and subnet mask settings in the WinCC project. Restart the WinCC Runtime and re-establish the communication channel.
System overheating or thermal shutdown
Check ambient temperature around the panel PC installation. Inspect ventilation openings for blockages or dust accumulation. Verify fan operation if the unit is fan-cooled.
Ensure ambient temperature does not exceed 45 °C. Clean ventilation openings and air filters. Improve enclosure ventilation if necessary. Replace the cooling fan if it is found to be faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page



