• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA10-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA10-0BJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA10-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA10-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single ruggedized enclosure suitable for direct panel installation.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing compatibility with SIMATIC WinCC and other Siemens SCADA and HMI software packages. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for 24 V DC supply voltage. The fanless or fan-cooled design options and industrial-grade components ensure reliable continuous operation.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with standard PC software and Siemens automation platforms makes it a practical choice for visualization, data logging, and supervisory control tasks.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    Processor Intel Celeron
    Operating System Windows XP / Windows 2000 (compatible)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error or BIOS POST failure during boot sequence.
    Check hardware connections, reseat RAM and storage media. Verify BIOS settings and restore defaults if necessary.
    Event ID: 1000
    Application fault or software exception in the HMI runtime (e.g., WinCC Runtime crash).
    Restart the HMI application. Check Windows Event Viewer for detailed error logs. Reinstall the HMI software if the fault persists.
    Event ID: 7000
    Service failed to start during Windows boot, often related to a missing or corrupt driver.
    Check Windows Event Viewer under System logs. Reinstall the relevant driver or restore the operating system from a backup image.
    Event ID: 7036
    A system service entered a stopped state unexpectedly, which may affect HMI communication or data acquisition.
    Identify the affected service in Event Viewer and restart it manually. Configure the service to restart automatically on failure.
    Communication Error
    Loss of communication between the Panel PC and the PLC or SCADA system via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check firewall settings and confirm the PLC communication driver is correctly configured in WinCC.
    Watchdog Timeout
    The system watchdog has detected that the operating system or application has become unresponsive.
    Perform a controlled restart of the Panel PC. Investigate CPU load and memory usage. Check for software conflicts or runaway processes.
    Storage Media Error
    Read/write error on the Compact Flash card or hard disk drive used as the system storage medium.
    Check the storage device connection and integrity. Replace the Compact Flash card or HDD if errors persist. Restore the system image from backup.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AA10-0BJ0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.

    What display size and resolution does this Panel PC have?

    The 6AV7611-0AA10-0BJ0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).

    Which HMI and SCADA software is compatible with this Panel PC?

    This Panel PC is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard PC-based HMI and SCADA software packages that support the installed Windows operating system.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets for panel-mounted industrial use.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply connector. Verify the display backlight is functioning by looking for a faint image on the screen. Inspect internal fuse and power supply board.

    Restore correct 24 V DC supply. If the backlight has failed, replace the CCFL backlight or the display assembly. If the power supply board is faulty, replace or repair it.

    Touch screen does not respond or is inaccurate

    Check if the touch controller is recognized in Windows Device Manager. Verify that the touch screen calibration has not been corrupted. Inspect the touch screen ribbon cable connection.

    Recalibrate the touch screen using the Windows calibration utility or the Siemens touch calibration tool. If the touch controller is not detected, reinstall the touch screen driver. Replace the touch screen overlay if physically damaged.

    Panel PC fails to boot or continuously restarts

    Check the Compact Flash card or hard disk for errors using a bootable diagnostic tool. Inspect the BIOS for correct boot device settings. Check for Windows system file corruption.

    Restore the operating system from a backup image onto a new Compact Flash card or HDD. Reset BIOS to default settings. If the mainboard is faulty, replace the computing module.

    Loss of communication with PLC or network

    Verify Ethernet cable integrity and switch port status. Check IP address configuration in Windows Network Settings. Confirm the WinCC communication driver and PLC project settings are correct.

    Replace the Ethernet cable if faulty. Reconfigure the IP address to match the network subnet. Reinstall the communication driver and verify the PLC channel configuration in the HMI project.

    System runs slowly or HMI application freezes

    Check CPU and RAM utilization in Windows Task Manager. Inspect the Compact Flash card for available free space and read/write errors. Look for background processes consuming excessive resources.

    Close unnecessary background applications and disable non-essential startup programs. Replace the Compact Flash card with a new one and restore the system image. Increase virtual memory settings if RAM is insufficient.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart