Siemens 6AV7414-2AB00-0KB0 SIMATIC IPC477C
€ 2.381,00
The Siemens 6AV7414-2AB00-0KB0 is a panel PC belonging to the SIMATIC IPC477C series, manufactured by Siemens as part of their industrial computing portfolio. This unit is a high-performance industrial panel PC designed for demanding automation and visualization tasks, combining a robust touch-enabled display with a powerful computing platform in a single integrated housing. It is engineered for continuous operation in industrial environments and integrates seamlessly into Siemens automation architectures.
The SIMATIC IPC477C features a 15-inch TFT display with a resolution of 1024 x 768 pixels and resistive touch technology, enabling reliable operator interaction even in harsh conditions. The unit is powered by an Intel Core 2 Duo or Celeron processor depending on the configuration, and supports Windows XP, Windows 7, or Windows Embedded Standard operating systems. It provides multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity, along with a PCI expansion slot for additional interface cards. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The IPC477C is widely deployed in machine tool control, process visualization, and factory automation applications across industries such as automotive manufacturing, food and beverage processing, and chemical production. Its combination of a full PC platform with an integrated operator panel makes it suitable for applications requiring both complex HMI software and local data processing, such as SCADA systems, MES integration, and advanced recipe management. The fanless or fan-cooled variants allow it to be adapted to environments with varying thermal requirements.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT LCD |
| Display Colors | 16.7 million colors |
| Touch Technology | Resistive |
| IP Protection Rating (Front) | IP65 |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | 2x Ethernet RJ45, 4x USB, optional PROFIBUS/PROFINET |
| Expansion | 1x PCI slot |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series | SIMATIC IPC477C |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Fan failure detected on units equipped with active cooling.
Check fan connector and fan operation. Clean or replace the cooling fan. Ensure ambient temperature is within specification. - Event ID: 300
- Watchdog timeout triggered, indicating the system software has stopped responding.
Investigate application software for hangs or infinite loops. Update or reinstall the operating system and HMI runtime software. - Event ID: 400
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connections and switch port status. Verify network adapter settings in the operating system device manager. - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen using the calibration utility in the operating system control panel. If the issue persists, check the touch controller ribbon cable connection. - Event ID: 600
- Power supply undervoltage detected; supply voltage has dropped below the 24 V DC operating threshold.
Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated for the IPC load and check wiring for voltage drop. - Event ID: 700
- Memory error detected during POST or during runtime operation.
Reseat RAM modules if accessible. Run a memory diagnostic utility. Replace faulty RAM module if errors are confirmed.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7414-2AB00-0KB0?
The SIMATIC IPC477C operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What operating systems are supported by the IPC477C?
The IPC477C supports Windows XP Professional, Windows 7, and Windows Embedded Standard, depending on the ordered configuration. The specific OS is typically pre-installed at the factory.
What is the front panel protection rating of this panel PC?
The front panel of the SIMATIC IPC477C carries an IP65 protection rating, providing full protection against dust ingress and resistance to water jets.
Can the IPC477C be used with Siemens WinCC or STEP 7 software?
Yes, the IPC477C is fully compatible with Siemens WinCC SCADA software and can be integrated with STEP 7 and TIA Portal engineering environments for automation projects.
What communication interfaces are available on this unit?
The unit provides two Ethernet RJ45 ports, four USB ports, and optional PROFIBUS or PROFINET interfaces. An internal PCI expansion slot allows for additional communication cards.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is illuminated. Inspect internal fuses if accessible.
Restore the correct 24 V DC supply. If the supply is correct and the display remains blank, the backlight inverter or the display panel itself may be faulty and require replacement.
Touch screen does not respond or registers incorrect touch positions
Attempt to recalibrate the touch screen through the operating system control panel. Check for physical damage or contamination on the screen surface.
Run the touch screen calibration utility. If calibration fails, inspect the ribbon cable connecting the touch controller to the mainboard. Replace the touch screen assembly if the controller is defective.
System fails to boot or continuously restarts
Connect an external monitor via VGA if available to observe POST messages. Check the storage device (HDD or CompactFlash) for errors using diagnostic tools.
Replace or reimage the storage device with a valid operating system image. Verify BIOS settings are correct. If the mainboard is suspected, arrange for board-level repair or replacement.
Ethernet communication is not established
Check the Ethernet cable and verify the link LED on the RJ45 port is active. Open the device manager in the operating system to check for driver errors on the network adapter.
Replace the Ethernet cable and verify switch port configuration. Reinstall network adapter drivers if missing. If the port is physically damaged, use the second Ethernet port or install a PCI network card.
Unit overheats and shuts down unexpectedly
Check the ambient temperature around the panel PC and ensure ventilation clearances are maintained. On fan-cooled units, verify that the fan is operating correctly.
Reduce ambient temperature or improve cabinet ventilation. Clean dust from fan and ventilation slots. Replace the cooling fan if it is not operating. Verify that the unit is not installed in a sealed enclosure without adequate heat dissipation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page