Siemens 6AV7413-4AB00-1FW0 SIMATIC IPC477C
€ 1.010,00
The Siemens 6AV7413-4AB00-1FW0 is a panel PC belonging to the SIMATIC IPC477C series, a high-performance industrial PC platform developed by Siemens for demanding automation and process visualization environments. This unit integrates computing power and HMI functionality into a single panel-mounted device, designed for use in industrial control cabinets and machine front panels. It is part of Siemens' SIMATIC Industrial PC portfolio, which is engineered to meet the rigorous requirements of continuous industrial operation.
The IPC477C features a 15-inch TFT display with a resistive touch screen and a resolution of 1024 x 768 pixels (XGA). It is powered by an Intel Core 2 Duo or Celeron processor depending on the variant, and supports Windows XP Professional or Windows Embedded Standard operating systems. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and optionally PROFIBUS or PROFINET interfaces, enabling seamless integration into Siemens automation networks. It is built to withstand industrial environments with an IP65 protection rating on the front panel and supports a wide operating temperature range.
The SIMATIC IPC477C is widely deployed in manufacturing automation, process industries, and machine tool applications where a combined HMI and computing platform is required. Its compatibility with Siemens WinCC and STEP 7 engineering software makes it a natural fit for SIMATIC S7-based control architectures. Industries such as automotive, food and beverage, chemical processing, and packaging rely on this platform for supervisory control, data acquisition, and operator interface functions.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 90 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x Ethernet RJ45, 4x USB 2.0 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC477C |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify boot device is correctly configured in BIOS. Replace storage medium if faulty. - Event ID: 200
- Fan failure detected; cooling fan not operating within specified speed range.
Check fan connector and fan unit for obstruction or mechanical failure. Replace the cooling fan assembly if defective. - Event ID: 300
- Temperature warning: internal temperature has exceeded the defined threshold.
Check ambient temperature and ventilation around the panel PC. Clean air filters and ensure adequate clearance around the unit. Verify fan operation. - Event ID: 400
- Hard disk or storage device not found or not accessible at startup.
Reseat the hard disk or CompactFlash card. Check power and data connectors. Replace storage device if not recognized after reseating. - Event ID: 500
- Ethernet interface communication failure or link not established.
Check Ethernet cable and switch/hub connection. Verify network configuration settings in the operating system. Replace cable or network adapter if fault persists. - Event ID: 600
- 24 V DC supply voltage out of tolerance or power interruption detected.
Measure supply voltage at the power connector. Ensure power supply unit provides stable 24 V DC within the specified tolerance range. Replace power supply if necessary. - Event ID: 700
- USB device error or unrecognized USB peripheral connected.
Disconnect and reconnect the USB device. Try a different USB port. Verify the device is compatible and drivers are installed correctly.
Frequently Asked Questions
What operating systems are supported by the SIMATIC IPC477C (6AV7413-4AB00-1FW0)?
The SIMATIC IPC477C supports Windows XP Professional and Windows Embedded Standard operating systems, depending on the specific configuration ordered.
What is the supply voltage for the 6AV7413-4AB00-1FW0?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC industrial panel PCs.
Is the 6AV7413-4AB00-1FW0 compatible with Siemens WinCC?
Yes, the SIMATIC IPC477C is fully compatible with Siemens WinCC SCADA and visualization software, making it suitable for use in SIMATIC S7-based automation systems.
What is the front panel protection rating of this unit?
The front panel of the 6AV7413-4AB00-1FW0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel mounting.
What communication interfaces are available on this panel PC?
The unit provides two Ethernet RJ45 ports and four USB 2.0 ports as standard interfaces, with optional PROFIBUS or PROFINET connectivity depending on the configuration.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the power LED status. Measure voltage at the internal power supply output to the display backlight.
Ensure the 24 V DC supply is within tolerance. If the backlight has failed, replace the inverter board or display assembly. If the power supply is faulty, replace the internal power supply module.
Touchscreen does not respond or registers incorrect touch positions
Check if the touchscreen driver is correctly installed in the operating system. Perform a touchscreen calibration using the Siemens calibration utility. Inspect the touchscreen surface for damage or contamination.
Recalibrate the touchscreen using the built-in calibration tool. If calibration does not resolve the issue, reinstall the touchscreen driver. Replace the touchscreen panel if physical damage is present.
Unit fails to boot or operating system does not load
Check BIOS settings for correct boot device selection. Inspect the hard disk or CompactFlash card for errors using diagnostic tools. Listen for POST beep codes that may indicate hardware failure.
Restore BIOS to default settings and verify boot order. Replace the hard disk or CompactFlash card with a correctly imaged replacement. If the motherboard is faulty, replace the computing module.
Ethernet communication is not established
Verify the Ethernet cable connection and check link LEDs on the RJ45 port. Confirm IP address configuration in the operating system. Test with a known-good cable and switch port.
Replace the Ethernet cable if defective. Reconfigure the network adapter settings in the operating system. If the onboard Ethernet port is faulty, use an alternative port or replace the motherboard.
Unit overheats and shuts down unexpectedly
Check the ambient temperature around the panel PC. Inspect the cooling fan for correct operation and verify that air vents are not blocked. Review the system event log for temperature-related entries.
Improve ventilation around the unit and reduce ambient temperature if possible. Clean or replace the cooling fan. Ensure the panel cutout dimensions provide adequate thermal clearance as specified in the installation manual.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page