• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7264-3BM07-0AA0 SIMATIC IPC477C
    Awaiting product image

    Siemens 6AV7264-3BM07-0AA0 SIMATIC IPC477C

    € 1.769,00

    Reset
    Clear
    SKU: 6AV7264-3BM07-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7264-3BM07-0AA0 is an industrial panel PC belonging to the SIMATIC IPC477C series, manufactured by Siemens. It is a high-performance embedded panel PC designed for demanding HMI and SCADA applications in industrial environments. The unit integrates a flat-panel display with a built-in computing platform, offering a compact all-in-one solution for machine-level visualization and control tasks.

    The IPC477C features a 15-inch TFT display with a resolution of 1024 x 768 pixels and resistive touch technology, enabling reliable operation even with gloved hands. It is powered by an Intel Core 2 Duo processor and supports Windows XP Professional or Windows Embedded Standard operating systems. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, and is built to withstand industrial conditions with a fanless design option for reduced maintenance. The front panel meets IP65 protection rating, making it suitable for wash-down and dusty environments.

    The SIMATIC IPC477C is widely used in the automotive, food and beverage, pharmaceutical, and machine tool industries where robust, long-lifecycle panel PCs are required. It integrates seamlessly with Siemens SIMATIC WinCC and other SCADA software platforms, making it a natural fit for Siemens-based automation architectures. Its industrial-grade construction and long-term availability of spare parts make it a preferred choice for OEMs and system integrators building machines with extended service lifetimes.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels
    Display Type TFT LCD
    Touch Technology Resistive
    Processor Intel Core 2 Duo
    Operating System Windows XP Professional / Windows Embedded Standard
    Input/Operating Voltage 24 V DC
    Front Panel Protection Rating IP65
    Communication Interface 2x Ethernet RJ45, 4x USB, 1x RS-232
    Mounting Panel mounting
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 1001
    Operating system startup failure or boot error detected during POST sequence.
    Check storage medium (HDD/SSD/CF card) for errors. Verify OS installation integrity and replace storage medium if necessary.
    Event ID: 1003
    Application error causing system crash or unexpected shutdown of the HMI runtime software.
    Review Windows Event Viewer logs to identify the faulting application. Reinstall or update the HMI runtime software such as WinCC.
    Event ID: 6008
    Unexpected system shutdown recorded, indicating a possible power loss or hardware fault.
    Check 24 V DC supply voltage stability. Inspect power supply unit and all connectors for loose contacts or voltage drops.
    Communication Error
    Loss of communication between the panel PC and the connected PLC or field devices.
    Verify Ethernet cable connections and network switch status. Check IP address configuration and firewall settings on the IPC.
    Watchdog Timeout
    Hardware watchdog timer has triggered due to system hang or unresponsive operating system.
    Perform a controlled restart. If recurring, check CPU load, memory usage, and consider reinstalling the operating system.
    Temperature Warning
    Internal temperature of the IPC has exceeded the defined threshold.
    Check ambient temperature and ensure adequate ventilation or cooling around the unit. Clean any air vents or filters if present.
    Storage Medium Error
    Read/write error detected on the internal hard disk, SSD, or CompactFlash card.
    Run a disk diagnostic utility. Back up data immediately and replace the storage medium with a compatible unit.
    Display Backlight Failure
    Display backlight has failed or brightness has dropped significantly, resulting in a dark or unreadable screen.
    Replace the backlight unit or the display assembly. Check the backlight inverter board and associated connectors for damage.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7264-3BM07-0AA0?

    The SIMATIC IPC477C operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What is the front panel protection rating of this panel PC?

    The front panel of the 6AV7264-3BM07-0AA0 meets IP65 protection rating, providing protection against dust and water jets.

    Is this panel PC compatible with Siemens WinCC SCADA software?

    Yes, the SIMATIC IPC477C is fully compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software, as it runs a Windows-based operating system.

    What type of touch screen does this unit use?

    The 6AV7264-3BM07-0AA0 uses resistive touch technology, which allows operation with gloved hands and is well-suited for industrial environments.

    Can the storage medium be replaced or upgraded on this panel PC?

    Yes, the internal storage medium such as the hard disk or CompactFlash card can be replaced. It is recommended to use Siemens-approved storage media to ensure compatibility and reliability.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power input connector. Verify that the power LED indicator is active. Measure backlight inverter output voltage.

    Restore correct supply voltage if out of range. If supply is correct, replace the backlight inverter or display assembly. Check internal fuse if present.

    Touch screen does not respond to input

    Check if the operating system has fully booted and the HMI runtime is active. Test touch input in the Windows desktop environment to isolate hardware from software issues.

    Recalibrate the touch screen using the Windows touch calibration utility. If unresponsive at hardware level, replace the touch screen overlay or the complete display assembly.

    Panel PC fails to boot and shows POST error

    Attempt to boot from an external USB device to determine if the internal storage medium has failed. Check BIOS settings for correct boot device order.

    Replace the internal HDD, SSD, or CompactFlash card with a compatible unit and reinstall the operating system and HMI software.

    Loss of communication with PLC over Ethernet

    Verify physical Ethernet connection and check link LEDs on the RJ45 port. Use ping command to test network connectivity between the IPC and the PLC.

    Replace Ethernet cable if faulty. Reconfigure IP address settings to match the network subnet. Check and update network adapter drivers if necessary.

    System runs slowly or HMI runtime freezes intermittently

    Monitor CPU and RAM usage via Windows Task Manager. Check for background processes consuming excessive resources. Verify that the storage medium is not failing using disk diagnostics.

    Terminate unnecessary background processes or services. Increase virtual memory if RAM is insufficient. Replace the storage medium if disk errors are detected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart