Siemens 6AV7261-0GK10-1AA0 SIMATIC IPC277D
€ 2.164,00
The Siemens 6AV7261-0GK10-1AA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC family. This unit is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a touch-enabled display with an embedded PC architecture. It is intended for demanding industrial environments where reliability, compact installation, and integrated operation are required.
The IPC277D features a widescreen display with a resistive or projected capacitive touch interface, depending on the variant, and is built around an Intel Atom processor platform for efficient, fanless operation. It supports communication via standard industrial interfaces including PROFINET, Ethernet, USB, and serial ports, enabling integration with Siemens SIMATIC controllers and third-party systems. The unit runs Windows Embedded Standard 7 or compatible embedded operating systems, and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress.
The SIMATIC IPC277D is widely deployed in machine-level HMI applications across industries such as automotive manufacturing, food and beverage processing, pharmaceutical production, and general factory automation. Its fanless design and robust construction make it suitable for environments with vibration, temperature variation, and contamination. It is commonly used to run SIMATIC WinCC flexible, WinCC Runtime, or other SCADA and visualization software packages.
Technical Specifications
| Series | SIMATIC IPC277D |
|---|---|
| Display Size | 15 in (widescreen) |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Atom E3827 (dual-core) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 35 W |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | 2x PROFINET/Ethernet (RJ45), 4x USB 2.0, 1x USB 3.0, 1x RS-232/RS-422/RS-485 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Operating System | Windows Embedded Standard 7 (WES7) |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or boot error detected during POST
Check power supply voltage (24 V DC), verify storage media integrity, and inspect for corrupted OS installation. Re-image the storage device if necessary. - Event ID: 1000
- Application crash or unexpected software termination
Review Windows Event Viewer logs for the faulting application. Reinstall or update the HMI runtime software (e.g., WinCC Runtime). - Event ID: 7000
- Service failed to start during Windows boot sequence
Check Windows Services configuration. Ensure required HMI services are set to automatic start. Reinstall the affected software if the service is corrupted. - Event ID: 6008
- Unexpected system shutdown recorded by Windows
Investigate power supply stability. Check for overtemperature conditions. Review hardware event logs for underlying hardware faults. - Communication Error
- Loss of communication between the IPC and the connected SIMATIC controller via PROFINET or Ethernet
Verify network cable connections, check IP address configuration, and confirm PROFINET device name assignment. Inspect switch or router settings for network faults. - Touchscreen Calibration Error
- Touch input is misaligned or unresponsive after startup
Run the touchscreen calibration utility from the Windows Control Panel. If unresponsive, check the touch controller driver installation and USB/internal connection of the touch overlay. - Temperature Warning
- Internal temperature of the IPC has exceeded the recommended operating threshold
Ensure ambient temperature is within 0–50 °C. Check that ventilation slots are not obstructed. Verify that the unit is not installed in a sealed enclosure without adequate thermal management.
Frequently Asked Questions
What operating system does the 6AV7261-0GK10-1AA0 run?
This unit runs Windows Embedded Standard 7 (WES7), which is optimized for industrial HMI and embedded computing applications.
What HMI software is compatible with the SIMATIC IPC277D?
The IPC277D is compatible with Siemens SIMATIC WinCC Runtime, WinCC flexible Runtime, and other PC-based SCADA or visualization software that supports Windows Embedded Standard 7.
What is the supply voltage for this panel PC?
The 6AV7261-0GK10-1AA0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel PCs.
Is the front panel of the IPC277D protected against dust and water?
Yes, the front panel carries an IP65 rating, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.
Can the IPC277D communicate with non-Siemens PLCs?
Yes, the unit supports standard Ethernet and serial communication interfaces (RS-232/RS-422/RS-485), allowing integration with third-party controllers using appropriate drivers or OPC connectivity.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.
Touchscreen does not respond to input
Verify that the operating system has fully booted. Check Device Manager for touch controller driver errors. Test with a USB mouse to confirm the OS is responsive.
Reinstall the touch controller driver. If the hardware is unresponsive after driver reinstallation, inspect the internal touch controller connection or replace the touch overlay assembly.
Unit fails to boot and displays a BIOS or boot error
Attempt to access the BIOS/UEFI setup during POST. Check whether the storage device (CompactFlash or SSD) is detected. Listen or observe for POST error indicators.
Re-seat the storage media. If the storage device is not detected, replace it and re-image with the correct OS and software image for the IPC277D.
PROFINET communication is lost intermittently
Check the Ethernet cable and connector at both the IPC and the switch. Use the Windows network diagnostics or a network analyzer to identify packet loss or link drops.
Replace the Ethernet cable if damaged. Verify the PROFINET device name and IP address configuration in the Siemens engineering tool (TIA Portal or STEP 7). Check switch port settings for auto-negotiation conflicts.
System overheats and shuts down unexpectedly
Monitor the internal temperature via the SIMATIC IPC DiagMonitor tool or BIOS hardware monitor. Check ambient temperature and airflow around the installed unit.
Ensure the installation environment is within the 0–50 °C operating range. Remove any obstructions from ventilation areas. If the unit is installed in a sealed enclosure, add external cooling or heat exchangers.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page