Siemens 6AV7264-6EA00-0AA0 SIMATIC IPC477C
€ 1.870,00
The Siemens 6AV7264-6EA00-0AA0 is a panel PC belonging to the SIMATIC IPC477C series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 15-inch industrial panel PC designed for demanding automation and process visualization environments, combining computing power with a robust, panel-mount form factor. It is intended for use as a high-performance HMI station capable of running SCADA, visualization, and control software in industrial settings.
The SIMATIC IPC477C features a 15-inch TFT display with a resolution of 1024 x 768 pixels and resistive touchscreen capability, allowing reliable operator interaction even in harsh conditions. The unit is powered by an Intel Core 2 Duo processor and supports Windows-based operating systems, providing a familiar software environment for engineering and runtime applications. It includes multiple communication interfaces such as USB ports, Ethernet (RJ45), and optional PROFIBUS or PROFINET connectivity, enabling seamless integration into existing automation networks. The front panel achieves IP65 protection rating, making it resistant to dust and water ingress from the front side.
The IPC477C is widely deployed in manufacturing, automotive, chemical, and process industries where a robust, all-in-one HMI and computing solution is required. It is commonly used to run Siemens WinCC, WinCC flexible, or third-party SCADA software on the plant floor. Its panel-mount design and industrial-grade construction make it suitable for integration into control cabinets and operator stations exposed to vibration, temperature variation, and continuous operation demands.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT LCD |
| Display Colors | 16.7 million colors |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Core 2 Duo |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | 2x USB, 2x Ethernet RJ45, optional PROFIBUS/PROFINET |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mount |
| Series/Product Family | SIMATIC IPC477C |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard drive integrity, verify boot device order in BIOS, and replace storage media if drive errors are detected. - Event ID: 200
- Fan failure or thermal management warning indicating cooling system malfunction.
Inspect and clean cooling fans, ensure ventilation clearances are maintained, and replace faulty fan units if necessary. - Event ID: 300
- Watchdog timeout event indicating the application or OS has become unresponsive.
Restart the panel PC, check for software deadlocks or resource conflicts, and update or reinstall the runtime application. - Event ID: 400
- Battery low warning for the CMOS real-time clock backup battery.
Replace the internal CMOS battery (typically CR2032) to maintain BIOS settings and system clock accuracy. - Event ID: 500
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connections, verify network switch port status, and inspect the RJ45 connector for damage. - Event ID: 600
- USB device error or unrecognized USB peripheral connected to the panel PC.
Disconnect and reconnect the USB device, try an alternative USB port, and verify device driver compatibility with the installed OS. - Event ID: 700
- Hard disk drive or SSD read/write error indicating potential storage media failure.
Run disk diagnostics, back up data immediately, and replace the storage drive if errors persist.
Frequently Asked Questions
What operating systems are supported by the SIMATIC IPC477C (6AV7264-6EA00-0AA0)?
The SIMATIC IPC477C supports Windows XP Professional, Windows 7, and Windows Embedded Standard 7, depending on the specific configuration ordered. The operating system is typically pre-installed by Siemens.
What is the supply voltage for the 6AV7264-6EA00-0AA0?
This panel PC operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC industrial panel PCs intended for cabinet installation.
Is the front panel of the IPC477C protected against dust and water?
Yes, the front panel of the SIMATIC IPC477C achieves IP65 protection rating, providing full protection against dust ingress and resistance to water jets from any direction.
Can the IPC477C run Siemens WinCC or WinCC flexible?
Yes, the SIMATIC IPC477C is fully compatible with Siemens WinCC and WinCC flexible SCADA and HMI runtime software, and is a common platform for these applications in industrial environments.
What communication interfaces are available on the 6AV7264-6EA00-0AA0?
The unit provides two USB ports, two Ethernet RJ45 interfaces, and optional PROFIBUS or PROFINET connectivity depending on the configuration, enabling integration into a wide range of automation network architectures.
Troubleshooting
Display remains blank after power on
Measure 24 V DC supply voltage at the power input connector. Check internal fuses and verify the power LED status on the unit.
Restore correct supply voltage within the 24 V DC specification. Replace any blown internal fuses and, if the backlight fails to illuminate, arrange replacement of the backlight or display assembly.
Touchscreen does not respond to input or is misaligned
Check if the touch controller is recognized in Device Manager under the installed OS. Verify that no physical damage or contamination is present on the screen surface.
Recalibrate the resistive touchscreen using the OS calibration utility. If calibration fails, update or reinstall the touch controller driver. Replace the touchscreen overlay if physical damage is confirmed.
Panel PC fails to boot or continuously restarts
Observe POST messages on screen during startup. Connect an external keyboard and enter BIOS to check boot device order and hard drive detection status.
Verify the hard drive or SSD is correctly seated and detected in BIOS. Restore BIOS defaults if settings are corrupted. Replace the storage drive if disk errors are reported during diagnostics.
Ethernet communication not established with the automation network
Check the link LED on the RJ45 port. Verify IP address configuration in the OS network settings and test connectivity with a known-good network cable.
Assign the correct IP address and subnet mask for the automation network. Replace the Ethernet cable if damaged. If the NIC is not detected, update network adapter drivers or arrange repair of the Ethernet interface.
System clock resets to incorrect date and time after power cycle
This typically indicates a depleted CMOS backup battery. Enter BIOS after power-on to confirm that date and time settings are lost between power cycles.
Replace the internal CMOS battery (CR2032 type) located on the motherboard. After replacement, re-enter correct date, time, and BIOS settings and save before exiting.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page