Siemens 6AV7260-4BA30-1BA1 SIMATIC IPC477C
€ 2.217,00
The Siemens 6AV7260-4BA30-1BA1 is a Panel PC belonging to the SIMATIC IPC477C series, designed for demanding industrial human-machine interface and process visualization applications. This unit is part of Siemens' SIMATIC Industrial PC family, combining a high-performance computing platform with a robust industrial-grade enclosure suitable for direct panel mounting. It serves as a powerful operator station capable of running SCADA, HMI, and process control software in real-time industrial environments.
The IPC477C features a 15-inch widescreen TFT display with touch functionality, supporting a resolution of 1024 x 768 pixels. It is equipped with an Intel Core processor platform and supports multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity. The unit operates on a 24 V DC supply voltage and is built to withstand industrial conditions, carrying an IP65 protection rating on the front panel. Onboard storage options include CompactFlash or hard disk drive configurations, and the system supports Windows-based operating systems for broad software compatibility.
The SIMATIC IPC477C is widely deployed in process industries such as chemical, pharmaceutical, oil and gas, and water treatment plants, where a robust and reliable operator interface is essential. It is also used in discrete manufacturing environments including automotive assembly lines and machine tool applications. Its fanless or low-maintenance design options and IP65 front protection make it particularly suitable for environments with dust, moisture, or washdown requirements.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | 2x Ethernet RJ45, 4x USB, optional PROFIBUS/PROFINET |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC IPC477C |
| Certifications | CE, UL, cULus |
| Operating System | Windows XP / Windows 7 (embedded options) |
Common Error Codes & System Events
- Event ID: 1001
- System startup failure or BIOS POST error detected during boot sequence.
Check power supply voltage at 24 V DC input. Verify that all internal connections and memory modules are seated correctly. Re-flash BIOS if necessary. - Event ID: 1003
- Operating system failed to load or boot device not found.
Check the CompactFlash card or hard disk drive for integrity. Verify boot order in BIOS settings. Replace storage medium if corrupted. - Event ID: 2001
- Watchdog timeout triggered, indicating the application software has stopped responding.
Restart the application software. Check for software exceptions or memory leaks. Update or reinstall the HMI/SCADA application if the issue persists. - Event ID: 3001
- Ethernet communication link failure on one or both network interfaces.
Inspect Ethernet cables and connectors. Verify network switch configuration. Check IP address settings and network driver status in the operating system. - Event ID: 4001
- CPU temperature exceeded safe operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel PC. Clean any dust from ventilation slots. Verify that the cooling fan (if fitted) is operational. - Event ID: 5001
- Touchscreen input not responding or calibration lost.
Recalibrate the touchscreen using the operating system's touch calibration utility. If unresponsive, check the internal touchscreen controller cable connection. Replace the touchscreen assembly if hardware fault is confirmed. - Event ID: 6001
- UPS or backup power module fault detected (if UPS option is installed).
Check the UPS battery charge level and replace the battery if depleted. Verify UPS module connections and configuration in the system BIOS or management software.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7260-4BA30-1BA1?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PCs intended for industrial cabinet or panel installation.
What is the front panel protection rating of this Panel PC?
The front panel of the IPC477C carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial environments.
What communication interfaces are available on this unit?
The 6AV7260-4BA30-1BA1 provides dual Ethernet RJ45 ports and multiple USB interfaces. Optional PROFIBUS or PROFINET modules can be integrated depending on the configuration ordered.
Is this Panel PC compatible with Siemens WinCC or STEP 7 software?
Yes, the SIMATIC IPC477C is fully compatible with Siemens WinCC SCADA and visualization software, as well as STEP 7 and TIA Portal engineering environments when running a supported Windows operating system.
Can the storage medium be replaced or upgraded in the field?
Yes, the CompactFlash card or hard disk drive used as the primary storage medium can typically be replaced in the field. It is recommended to create a full system image backup before performing any storage replacement.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the input connector. Check internal fuse and verify the power LED status on the unit.
Restore correct supply voltage within the specified range. Replace the internal fuse if blown. If the display backlight has failed, replace the backlight inverter or LCD assembly.
Touchscreen does not respond to input
Verify that the touchscreen is enabled in the operating system device manager. Check for physical damage to the screen surface and inspect the internal touchscreen controller ribbon cable.
Recalibrate the touchscreen via the OS calibration tool. Reseat the internal touchscreen cable. If the controller is faulty, replace the touchscreen assembly or controller board.
Panel PC fails to boot and shows BIOS error
Observe the POST error message on screen or listen for beep codes. Check whether the CompactFlash or HDD is detected in BIOS setup.
Reseat the storage medium and memory modules. If the storage device is not detected, replace it and restore the system image from backup. Re-flash the BIOS if corruption is suspected.
Ethernet communication is intermittent or lost
Check the Ethernet cable integrity and connector seating. Verify the link LED status on the RJ45 port. Review network adapter settings in the operating system.
Replace the Ethernet cable if damaged. Update the network adapter driver. If the onboard NIC is faulty, configure the secondary Ethernet port as the primary interface or replace the mainboard.
System overheats and shuts down unexpectedly
Check the ambient temperature around the panel installation. Inspect ventilation slots for dust blockage. Monitor CPU temperature using system diagnostics software.
Ensure the installation environment does not exceed 50 °C ambient. Clean ventilation slots with compressed air. Verify that any installed cooling fan is operational and replace it if defective.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page