Siemens 6AV7260-3EA20-0XX0 SIMATIC IPC277D
€ 1.995,00
The Siemens 6AV7260-3EA20-0XX0 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding human-machine interface applications. This unit is a 15-inch multi-touch panel PC that integrates computing performance with a robust industrial display in a single compact enclosure. It is designed for direct panel mounting and operates within the SIMATIC automation environment.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch screen supporting up to 5 simultaneous touch points. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity, enabling seamless integration into Siemens automation networks. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front side.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine building applications where a robust operator interface with touch capability is required. It is commonly found in automotive production lines, food and beverage processing, pharmaceutical manufacturing, and general factory automation environments. Its compatibility with SIMATIC WinCC and other Siemens HMI software makes it a natural fit for plants already running Siemens control infrastructure.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Display Colors | 16.7 million colors |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x RJ45 Ethernet (10/100/1000 Mbit/s), 4x USB 2.0 |
| Mounting | Panel mounting (portrait and landscape) |
| Series/Product Family | SIMATIC IPC277D |
| Certifications | CE, UL, cULus |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
Common Error Codes & System Events
- Event ID: 41
- The system has rebooted without cleanly shutting down first, typically caused by a power loss or system crash.
Check the 24 V DC power supply for stability and voltage drops. Review Windows Event Viewer for additional crash details and check for overheating conditions. - Event ID: 6008
- The previous system shutdown was unexpected, indicating a power failure or operating system crash.
Verify power supply integrity, check for loose connections at the power connector, and review system logs to identify the root cause of the unexpected shutdown. - BIOS POST Error
- Hardware initialization failure during Power-On Self-Test, which may indicate a RAM, storage, or hardware fault.
Reseat memory modules and storage devices. If the error persists, replace the faulty hardware component or contact Siemens technical support. - WinCC Runtime Error
- SIMATIC WinCC or HMI runtime software has encountered a fault and cannot start or has crashed during operation.
Check the WinCC project configuration for errors, verify software license validity, and ensure the operating system is free of corruption. Reinstall runtime software if necessary. - No Boot Device Found
- The system cannot locate a bootable storage device, indicating a failed or disconnected SSD/CFast card.
Check the CFast card or SSD is properly seated. Replace the storage medium if it has failed and restore the system image from backup. - Touchscreen Not Responding
- The PCT touch interface is unresponsive or registering incorrect touch positions.
Recalibrate the touch screen via the Windows control panel. Check for physical damage to the front glass. If recalibration fails, the touch controller or front panel assembly may require replacement. - Ethernet Link Failure
- One or both Ethernet interfaces fail to establish a network link, disrupting PROFINET or standard network communication.
Check Ethernet cable connections and switch port status. Verify network adapter settings in Windows Device Manager. Replace the cable or check for hardware damage to the RJ45 port.
Frequently Asked Questions
What is the display size and touch technology used in the 6AV7260-3EA20-0XX0?
The 6AV7260-3EA20-0XX0 features a 15-inch TFT widescreen display with projected capacitive (PCT) multi-touch technology supporting up to 5 simultaneous touch points.
What operating systems are supported by the SIMATIC IPC277D?
The IPC277D supports Windows Embedded Standard 7 and Windows 7. It is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the supply voltage for this panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What is the front panel protection rating of the IPC277D?
The front panel of the IPC277D carries an IP65 protection rating, providing full dust protection and protection against water jets. The rear of the unit is rated IP20.
What communication interfaces are available on this unit?
The 6AV7260-3EA20-0XX0 provides two RJ45 Gigabit Ethernet ports (10/100/1000 Mbit/s) and four USB 2.0 ports as standard interfaces, with optional PROFIBUS or PROFINET expansion.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power supply connector. Verify the power LED status. Attempt to connect an external monitor via available video output to determine if the issue is with the display or the system board.
If 24 V DC is confirmed but the display remains blank, replace the internal power supply board or the display backlight inverter. If no video output is detected on an external monitor, the main board may require replacement or repair.
System freezes or reboots unexpectedly during operation
Check Windows Event Viewer for critical errors or blue screen dump files. Monitor the operating temperature of the unit and verify that ventilation around the enclosure is adequate. Check the 24 V DC supply for voltage fluctuations.
Clean any dust from ventilation areas, ensure ambient temperature is within the 0-50 °C operating range, and stabilize the power supply. Update device drivers and BIOS firmware if outdated versions are identified.
Touch screen registers incorrect touch positions or is unresponsive
Attempt to recalibrate the touch screen through the Windows Tablet PC Settings or touch calibration utility. Check for visible cracks or contamination on the front glass surface.
Perform a full touch screen recalibration. If the issue persists after recalibration, clean the screen surface thoroughly and retest. A persistently faulty touch response indicates a failed PCT touch controller or damaged front panel assembly requiring replacement.
Unit fails to boot and displays 'No Boot Device' message
Enter the BIOS setup and check whether the CFast card or SSD is detected in the storage device list. Physically reseat the storage medium and reboot to confirm detection.
If the storage device is not detected after reseating, replace the CFast card or SSD. Restore the operating system and WinCC project from a system backup image. Ensure the replacement storage medium is of the correct type and capacity.
Ethernet communication lost with PLC or PROFINET network
Check the Ethernet cable and switch port for link activity LEDs. Open Windows Device Manager to verify the network adapter is functioning without errors. Ping the PLC or network gateway to test connectivity.
Replace the Ethernet cable if damaged. Reset the network adapter in Device Manager. If the adapter shows a fault, update the network driver or, if hardware failure is confirmed, the unit may require main board repair or replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page