Siemens 6AV7260-3DM42-0XX6 SIMATIC IPC277D
€ 1.870,00
The Siemens 6AV7260-3DM42-0XX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC product line. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a multi-touch display with a fanless embedded PC architecture. This unit is built to withstand the demanding environmental conditions typical of industrial production environments.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 4-wire multi-touch operation. It is powered by an Intel Atom processor and runs Windows Embedded Standard 7 or compatible embedded operating systems. The unit provides communication interfaces including PROFINET, USB ports, and optional PROFIBUS, and is designed for panel or arm mounting. Its fanless, diskless design minimizes maintenance requirements and enhances long-term reliability in dusty or vibration-prone environments.
The SIMATIC IPC277D is widely deployed in machine automation, process visualization, and production monitoring applications across industries such as automotive manufacturing, food and beverage processing, pharmaceutical production, and general factory automation. Its compatibility with Siemens WinCC and other SCADA/HMI software packages makes it a standard choice for integrating visualization tasks directly into Siemens TIA Portal-based automation architectures. The rugged enclosure and IP65-rated front panel make it suitable for installation in control cabinets and machine panels exposed to washdowns or particulate contamination.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch |
| Operating Voltage | 24 V DC |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 |
| Communication Interface | PROFINET (2x RJ45), USB 2.0, USB 3.0 |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting / arm mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the operating system failed to boot correctly, possibly due to corrupted system image or storage media fault.
Check the CompactFlash card or SSD for errors. Re-image the storage medium with a valid system image if necessary. - Event ID: 1001
- Application crash or unexpected software termination detected by Windows Error Reporting.
Review Windows Event Viewer logs to identify the faulting application. Reinstall or update the HMI runtime software (e.g., WinCC flexible or WinCC RT). - PROFINET Communication Error
- Loss of PROFINET communication between the Panel PC and the connected PLC or network devices.
Verify Ethernet cable connections on both RJ45 ports. Check IP address configuration and PROFINET device name assignment in TIA Portal. - Watchdog Timeout
- The system watchdog timer has triggered, indicating the operating system or application has become unresponsive.
Perform a controlled restart. Investigate CPU load and running processes. Ensure the HMI application is not overloaded or deadlocked. - Temperature Warning
- Internal temperature sensor has detected an elevated operating temperature approaching the upper limit.
Check ambient temperature and ventilation around the unit. Ensure the panel cutout ventilation clearances are maintained per installation guidelines. - Storage Media Error
- Read/write errors detected on the internal CompactFlash card or SSD storage device.
Back up project data immediately. Replace the storage medium and restore the system image. Use only Siemens-approved storage media for IPC277D. - Power Supply Undervoltage
- The 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
Frequently Asked Questions
What display size and touch technology does the 6AV7260-3DM42-0XX6 use?
This unit features a 15-inch widescreen TFT display with projected capacitive (PCT) multi-touch technology, supporting simultaneous multi-touch input.
What operating system is installed on the SIMATIC IPC277D?
The IPC277D typically ships with Windows Embedded Standard 7 (WES7). The specific variant in this SKU should be verified against the order documentation for the exact OS configuration.
Is the 6AV7260-3DM42-0XX6 compatible with Siemens TIA Portal and WinCC?
Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC Runtime and TIA Portal-based HMI projects, making it a standard visualization platform within Siemens automation architectures.
What is the IP protection rating of this Panel PC?
The front panel carries an IP65 rating, providing protection against dust and water jets. The rear of the unit is rated IP20.
Can the IPC277D be mounted on a swing arm or articulated arm?
Yes, the unit supports both panel mounting and arm mounting configurations, with a VESA-compatible mounting interface on the rear of the device.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within the specified tolerance. Inspect the power connector for loose or damaged contacts.
Restore the supply voltage to the correct level. If voltage is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.
Touch input is unresponsive or inaccurate
Check for contamination or moisture on the display surface. Verify that no grounding issues exist with the panel installation, as PCT touch screens are sensitive to improper grounding.
Clean the display surface with a dry, lint-free cloth. Ensure the panel is correctly grounded per the installation manual. If the issue persists, recalibrate or replace the touch screen assembly.
PROFINET communication is lost intermittently
Inspect the RJ45 Ethernet cables and connectors for damage or poor seating. Check the network switch or PLC port for link activity LEDs. Review the Windows Device Manager for network adapter errors.
Replace damaged cables and reseat connectors. Assign a static IP address if DHCP assignment is causing instability. Update the PROFINET driver or network adapter firmware if available.
System freezes or reboots unexpectedly during operation
Review the Windows Event Viewer System and Application logs for critical errors or watchdog events. Monitor CPU and memory usage to identify resource exhaustion. Check internal temperature via BIOS or Siemens diagnostic tools.
Reduce background processes and ensure the HMI application is optimized. If overheating is detected, improve panel ventilation. If hardware faults are logged, consider replacing the storage medium or RAM module.
Unit does not boot after a power interruption
A sudden power loss can corrupt the operating system or file system on the CompactFlash card or SSD. Attempt to boot into Windows recovery mode to assess the extent of the corruption.
Use a Siemens recovery image to restore the system partition. Consider implementing an uninterruptible power supply (UPS) to prevent future corruption from power interruptions.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page