Siemens 6AV7260-2GY31-0BX6 SIMATIC IPC277D
€ 1.870,00
The Siemens 6AV7260-2GY31-0BX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC product line. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a multi-touch display with a fanless embedded PC architecture. This unit is built to meet the demanding requirements of continuous industrial operation and integrates seamlessly into Siemens automation environments.
The IPC277D features a widescreen multi-touch display with a projected capacitive (PCT) touch panel, supporting multi-finger gesture input. It is powered by an Intel Atom processor and runs Windows Embedded Standard 7 or Windows 7, providing a capable computing platform for SCADA and HMI software such as Siemens WinCC. The unit offers multiple communication interfaces including USB ports, PROFINET/Ethernet ports, and optionally PROFIBUS, along with a CompactFlash or onboard flash storage option. The fanless, diskless design ensures low maintenance and high reliability in harsh industrial environments, and the front panel meets IP65 protection rating.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine-level HMI applications across industries such as automotive, food and beverage, pharmaceuticals, and chemical processing. Its panel-mount form factor and compatibility with Siemens TIA Portal and WinCC software make it a standard choice for machine builders and system integrators requiring a robust, integrated HMI computing solution. The multi-touch capability and wide operating temperature range further extend its suitability for demanding production environments.
Technical Specifications
| Series | SIMATIC IPC277D |
|---|---|
| Display Size | 15.6 inch widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch |
| Processor | Intel Atom E3827, 1.75 GHz |
| Operating System | Windows Embedded Standard 7 (WES7) or Windows 7 Ultimate |
| Storage | Onboard Flash / CompactFlash |
| Communication Interface | 2x PROFINET/Ethernet (RJ45), 4x USB 2.0, 1x USB 3.0 |
| Input/Operating Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mount (portrait or landscape) |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or boot error detected during POST sequence
Check power supply voltage at 24 V DC input, verify storage media (CompactFlash or onboard flash) integrity, and attempt system reboot. Re-image storage if OS is corrupted. - Event ID: 1000
- Application crash or unexpected software termination on the HMI runtime (e.g. WinCC Runtime)
Review Windows Event Viewer logs for faulting module details. Reinstall or repair the HMI runtime software. Check for memory or storage issues. - Event ID: 6008
- Unexpected system shutdown recorded — previous shutdown was unclean
Investigate power supply stability at 24 V DC input. Check for voltage dips or interruptions. Verify UPS or power conditioning if required. - BSOD: 0x0000007B
- Inaccessible boot device — operating system cannot access the boot storage device
Check CompactFlash or onboard flash connection and integrity. Re-image the storage medium with a valid OS image using Siemens recovery tools. - No Signal / Display Blank
- Display remains blank or shows no signal after power-on
Verify 24 V DC supply is within tolerance. Check internal display cable connections. Test with an external monitor via available video output if applicable. Replace backlight or display assembly if hardware fault is confirmed. - Touch Input Not Responding
- PCT touch panel does not register input or registers incorrect touch positions
Recalibrate the touch panel via the Windows control panel or Siemens panel configuration tool. Clean the touch surface. If fault persists, check touch controller driver and replace touch panel assembly if defective. - PROFINET Communication Error
- Loss of PROFINET communication between the IPC277D and connected controllers or network devices
Verify Ethernet cable connections and switch configuration. Check IP address settings and PROFINET device name assignment. Inspect network topology for faults using Siemens PRONETA or TIA Portal diagnostics. - Watchdog Timeout
- Hardware or software watchdog timer has triggered a system reset due to an unresponsive application or OS
Identify the process causing the hang via Event Viewer. Update or reinstall the HMI application. Check system resources (CPU, RAM) for overload conditions and optimize runtime configuration.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D 6AV7260-2GY31-0BX6 run?
This unit is supplied with Windows Embedded Standard 7 (WES7) or Windows 7 Ultimate, depending on the order configuration. It supports Siemens WinCC and other TIA Portal-compatible HMI software.
What is the supply voltage for this Panel PC?
The IPC277D operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel-mounted devices.
Does this Panel PC support multi-touch input?
Yes, the 6AV7260-2GY31-0BX6 features a projected capacitive (PCT) touch panel that supports multi-finger gesture input, including pinch-to-zoom and swipe gestures.
What communication interfaces are available on this unit?
The unit provides two PROFINET/Ethernet ports (RJ45), multiple USB 2.0 ports, and a USB 3.0 port. Optional PROFIBUS connectivity may be available depending on the configuration.
What is the front panel protection rating of this device?
The front panel of the IPC277D achieves IP65 protection, making it resistant to dust ingress and water jets, suitable for panel-mount installation in industrial enclosures.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power input connector and verify it is within the specified tolerance. Check internal fuse and inspect the display backlight and cable connections.
Restore supply voltage to within 24 V DC specification. Replace any blown internal fuse. If the backlight has failed, replace the display assembly. Re-seat internal display ribbon cables if loose.
Touch panel does not respond or registers incorrect touch positions
Determine whether the issue is hardware or driver-related by checking Device Manager for touch controller errors. Test touch response in the Windows calibration tool.
Recalibrate the touch panel using the Windows Tablet PC Settings or Siemens panel configuration utility. Reinstall the touch controller driver. If the touch surface is physically damaged, replace the PCT touch panel assembly.
System fails to boot or continuously restarts
Observe POST messages or error codes on screen during startup. Check the CompactFlash card or onboard flash for corruption using a PC or Siemens recovery environment.
Re-image the storage medium using the Siemens-provided recovery image or a valid OS backup. If the storage medium is faulty, replace the CompactFlash card with a compatible unit and restore the OS image.
PROFINET communication is lost or intermittent
Check physical Ethernet cable connections and verify link LEDs on the RJ45 ports are active. Use Siemens PRONETA or TIA Portal to scan the network and identify device configuration mismatches.
Replace faulty Ethernet cables or switch ports. Reassign the correct PROFINET device name and IP address via TIA Portal. Ensure firmware on the IPC277D and connected devices is up to date.
System performance is slow or HMI runtime freezes
Monitor CPU and RAM utilization via Windows Task Manager. Identify background processes consuming excessive resources. Check storage medium for fragmentation or low free space.
Terminate unnecessary background processes and disable non-essential startup programs. Optimize the WinCC or HMI runtime project for lower resource consumption. If the storage medium is nearly full, archive historical data and clear logs to free space.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page