• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-1JM31-0BX0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-1JM31-0BX0 SIMATIC IPC277D

    € 2.217,00

    Reset
    Clear
    SKU: 6AV7260-1JM31-0BX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-1JM31-0BX0 is a Panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is built for front-panel mounting and integrates seamlessly into the SIMATIC automation ecosystem.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting multi-finger gesture control for intuitive operator interaction. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 Ultimate operating systems, providing a flexible software platform. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity, enabling integration into a wide range of automation networks. The robust aluminum front panel provides IP65 protection on the front face, making it resistant to dust and water ingress.

    The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine tool applications where a reliable, full-featured industrial PC with HMI capabilities is required. Its fanless design options and wide operating temperature range make it suitable for harsh industrial environments including automotive production lines, food and beverage processing, and chemical plant control systems. The device is compatible with standard SIMATIC WinCC and WinCC flexible visualization software, making it a natural fit for Siemens-based automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Technology TFT LCD
    Touch Technology Projected Capacitive Multi-Touch (PCT)
    Display Resolution 1024 x 768 px (XGA)
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interfaces 2x RJ45 Ethernet, 4x USB, 1x DisplayPort
    Mounting Front panel mounting
    Certifications CE, UL, cULus
    Series SIMATIC IPC277D
    Operating System Support Windows Embedded Standard 7, Windows 7 Ultimate

    Common Error Codes and System Events

    Event ID: 1000
    Application error — a software application on the panel PC has crashed or terminated unexpectedly.
    Check Windows Event Viewer for details. Restart the application or reinstall the visualization software if the issue persists.
    Event ID: 6008
    Unexpected shutdown — the system was not shut down cleanly, indicating a possible power loss or hardware fault.
    Check the 24 V DC power supply for stability and correct voltage. Inspect wiring and connectors at the power input.
    BIOS POST Error
    Hardware initialization failure during power-on self-test, often related to RAM or storage device issues.
    Reseat or replace the RAM module. Check the CompactFlash card or SSD for errors and replace if necessary.
    WinCC Runtime Error
    SIMATIC WinCC or WinCC flexible runtime has encountered a configuration or communication error and cannot start.
    Verify the project configuration and PLC connection settings. Reload the project from the engineering station and restart the runtime.
    Network Connection Lost
    Ethernet communication to the PLC or SCADA system has been interrupted.
    Check Ethernet cable connections and switch/router status. Verify IP address configuration and network settings in Windows.
    Touchscreen Not Responding
    The PCT touch interface is unresponsive or registering incorrect touch positions.
    Recalibrate the touch screen via the SIMATIC IPC control panel utility. If the issue persists, check the touch controller connection internally or replace the touch overlay.
    Storage Device Full
    The internal storage (CompactFlash or SSD) has reached capacity, preventing logging or project saving.
    Delete unnecessary files, archive old log data, and ensure the visualization project is configured with appropriate data retention limits.

    Frequently Asked Questions

    What is the display size and touch technology of the 6AV7260-1JM31-0BX0?

    This unit features a 15-inch TFT LCD display with projected capacitive (PCT) multi-touch technology, supporting multi-finger gesture input.

    What operating systems are supported by the SIMATIC IPC277D?

    The IPC277D supports Windows Embedded Standard 7 and Windows 7 Ultimate, providing compatibility with standard industrial HMI and SCADA software packages.

    Is this panel PC compatible with SIMATIC WinCC?

    Yes, the IPC277D is fully compatible with SIMATIC WinCC and WinCC flexible visualization software, making it suitable for integration into Siemens automation systems.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7260-1JM31-0BX0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.

    What communication interfaces are available on this device?

    The unit provides dual RJ45 Ethernet ports, four USB ports, and a DisplayPort output, with optional PROFIBUS or PROFINET interface cards available depending on configuration.

    Troubleshooting

    Panel PC does not power on after supply voltage is applied

    Measure the 24 V DC supply voltage at the power input connector. Verify polarity and check for voltage drops under load.

    Ensure the power supply is rated for the panel's current draw (minimum 3 A at 24 V DC). Replace the power supply unit if voltage is out of tolerance or unstable.

    Display remains blank but the system appears to be running

    Check if the backlight is functioning by shining a light on the screen to detect a faint image. Verify DisplayPort or internal display cable connections.

    Replace the backlight inverter or the TFT display panel if the backlight has failed. If an external display shows output correctly, the internal display assembly requires replacement.

    Touch input is inaccurate or non-functional

    Attempt touch recalibration using the SIMATIC IPC control panel utility. Check Device Manager in Windows for touch controller driver errors.

    Recalibrate the touch screen. If the problem persists, update or reinstall the touch controller driver. In cases of hardware failure, replace the PCT touch overlay assembly.

    System boots to BIOS or fails to load the operating system

    Check the internal storage device (CompactFlash card or SSD) for recognition in BIOS. Run a storage diagnostic to detect read/write errors or device failure.

    Replace the CompactFlash card or SSD with a compatible unit and restore the operating system and project image from a backup.

    Ethernet communication to PLC is intermittent or lost

    Check physical Ethernet cable integrity and connector seating. Use Windows network diagnostics to verify IP configuration and ping the PLC address.

    Replace the Ethernet cable if damaged. Verify that IP address, subnet mask, and gateway settings are correctly configured. Check the network switch port for faults.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart