Siemens 6AV7260-1GN41-0BX0 SIMATIC IPC277D
€ 1.995,00
The Siemens 6AV7260-1GN41-0BX0 is a panel-integrated Industrial PC belonging to the SIMATIC IPC277D series, part of Siemens' SIMATIC IPC product family. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is engineered for seamless integration into control panels and machine fronts, offering a robust all-in-one solution for visualization and control tasks.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is equipped with an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar computing environment for SCADA and HMI software such as SIMATIC WinCC. Communication interfaces include PROFINET/Ethernet ports, USB 2.0 and USB 3.0 ports, and optional PROFIBUS connectivity, enabling integration into modern industrial networks. The front panel meets IP65 protection rating, ensuring resistance to dust and water ingress in harsh production environments.
The SIMATIC IPC277D is widely deployed in the manufacturing, automotive, food and beverage, chemical, and process industries where a combination of robust visualization and PC-based control is required. It is particularly suited for machine-level HMI applications, process visualization stations, and SCADA front-ends where operators require a responsive touch interface alongside full PC functionality. Its panel-mount design and wide operating temperature range make it suitable for integration directly into control cabinets and machine enclosures.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Display Colors | 16.7 million colors |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
| Communication Interface | 2x PROFINET/Ethernet (RJ45), 2x USB 2.0, 1x USB 3.0 |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected during POST.
Check storage media (SSD/CFast card) for errors. Verify OS integrity and re-image if necessary. Check BIOS settings for correct boot device order. - Event ID: 1001
- Application crash or unexpected software termination recorded in Windows Event Log.
Review Windows Event Viewer for detailed crash dump information. Update or reinstall the affected application. Check for memory or hardware faults using diagnostics tools. - Event ID: 6008
- Unexpected system shutdown recorded; previous shutdown was unexpected.
Check power supply stability at 24 V DC input. Inspect for overheating conditions and verify ventilation. Review event logs for preceding errors. - BIOS POST Error
- Hardware component not detected or failed during Power-On Self-Test.
Reseat RAM modules and internal connectors. Verify all peripheral cards are properly seated. Replace faulty hardware component if fault persists. - PROFINET Communication Error
- Loss of PROFINET network communication between IPC and connected controllers or devices.
Check Ethernet cable connections and switch configuration. Verify IP address settings and PROFINET device names. Inspect network topology for faults. - Temperature Warning
- Internal temperature has exceeded the defined threshold, triggering a thermal warning.
Check ambient temperature and ensure adequate ventilation around the unit. Clean air vents and fans if present. Verify operating environment is within 0 °C to +50 °C specification. - Watchdog Timeout
- System watchdog timer has expired, indicating the operating system or application has become unresponsive.
Investigate software causing the hang condition. Check CPU load and memory utilization. Update firmware and application software to latest versions.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7260-1GN41-0BX0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC IPC panel PCs intended for industrial cabinet installation.
What touch technology does the IPC277D use?
The IPC277D uses projected capacitive (PCT) multi-touch technology, supporting up to 5 simultaneous touch points for responsive and intuitive operator interaction.
Is the 6AV7260-1GN41-0BX0 compatible with SIMATIC WinCC?
Yes, the IPC277D is fully compatible with SIMATIC WinCC and other Siemens HMI and SCADA software packages, as it runs a standard Windows operating system environment.
What is the front panel protection rating of this unit?
The front panel of the IPC277D carries an IP65 protection rating, making it resistant to dust and low-pressure water jets, suitable for direct panel mounting in industrial environments.
What communication interfaces are available on this device?
The unit provides two PROFINET/Ethernet ports (RJ45), USB 2.0 and USB 3.0 ports, and optional PROFIBUS connectivity, enabling integration into a wide range of industrial network architectures.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power input connector. Check internal fuses and verify the power LED status indicator.
Restore correct 24 V DC supply if out of tolerance. Replace blown internal fuse with correct rating. If supply is correct and display remains blank, the backlight inverter or display panel may require replacement.
Touch input not responding or inaccurate
Check for physical damage or contamination on the touch surface. Verify touch driver installation and calibration settings within the operating system.
Clean the touch surface with a soft, dry cloth. Recalibrate the touch screen via the Windows control panel. If the issue persists, update or reinstall the PCT touch driver or replace the touch panel assembly.
Unit fails to boot or continuously restarts
Connect an external monitor via available video output to check for BIOS or OS error messages. Check the CFast card or SSD for errors using diagnostic software.
Re-image the storage media with a valid OS image. If hardware POST errors are reported, reseat internal components. Replace the storage media if it is found to be faulty.
PROFINET communication lost with PLC
Check Ethernet cable integrity and switch port status. Verify PROFINET device name and IP address configuration match the engineering project settings.
Replace faulty Ethernet cable. Reconfigure PROFINET device name and IP address using SIMATIC STEP 7 or TIA Portal. Ensure network switch supports PROFINET requirements.
System overheating or thermal shutdown
Check ambient temperature around the unit and inspect ventilation openings for blockage. Review system event logs for thermal warning entries.
Ensure the installation environment is within the 0 °C to +50 °C operating range. Clear any blockages from ventilation openings. If the unit has an internal fan, verify it is operational and replace if faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page