• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-1DA20-0BX6 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-1DA20-0BX6 SIMATIC IPC277D

    € 1.870,00

    Reset
    Clear
    SKU: 6AV7260-1DA20-0BX6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-1DA20-0BX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial panel PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch widescreen multi-touch panel PC that integrates computing power and HMI functionality into a single compact device. It is designed for direct panel mounting and operates within the SIMATIC HMI ecosystem.

    The IPC277D features a 15.6-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface supporting up to 5 simultaneous touch points, enabling intuitive operator interaction. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar computing environment for SCADA and visualization software. The unit includes multiple communication interfaces such as Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity, and carries an IP65 protection rating on the front panel for resistance to dust and water ingress.

    The SIMATIC IPC277D is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and process industries where robust operator panels with PC functionality are required. It is particularly suited for applications running Siemens WinCC, WinCC flexible, or third-party SCADA software directly on the panel. Its fanless design options and wide operating temperature range make it appropriate for installation in control cabinets and harsh industrial environments.

    Technical Specifications

    Display Size 15.6 inch (widescreen)
    Display Type TFT LCD
    Touch Technology Projected Capacitive (PCT) Multi-Touch, up to 5 touch points
    Display Resolution 1366 x 768 pixels
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W (typical)
    Processor Intel Atom E3827 (dual-core, 1.75 GHz)
    Operating System Windows Embedded Standard 7 / Windows 7
    Communication Interface 2x RJ45 Ethernet (10/100/1000 Mbps), 4x USB 2.0, 1x USB 3.0
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting (portrait and landscape)
    Certifications CE, UL, cULus
    Series SIMATIC IPC277D

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to corrupted system files or storage media failure.
    Check the Compact Flash or SSD storage device. Attempt system restore or re-image the operating system using the Siemens recovery medium.
    Event ID: 1001
    Application crash or unexpected software termination detected by Windows Error Reporting.
    Review Windows Event Viewer logs for the faulting application. Update or reinstall the affected software. Check for memory or hardware faults using diagnostics tools.
    Event ID: 6008
    Unexpected system shutdown — the previous system shutdown was unexpected, indicating a possible power failure or system hang.
    Verify the 24 V DC power supply stability. Check for overheating conditions and ensure adequate ventilation around the panel PC.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat internal memory modules and storage media. If the fault persists, replace the faulty hardware component or contact Siemens support.
    WinCC Runtime Error
    WinCC or WinCC flexible runtime fails to start or crashes during operation, often due to licensing or configuration issues.
    Verify the WinCC license is correctly installed and valid. Check project configuration for errors and ensure the runtime version matches the project version.
    Touch Input Not Responding
    The PCT touch screen does not register input, possibly due to driver failure, calibration loss, or hardware fault.
    Restart the HMI application and touch driver service. Recalibrate the touch screen via the Windows control panel. If unresolved, check the touch controller connection or replace the touch overlay.
    Network Connection Lost
    Ethernet communication to the PLC or network is interrupted, causing loss of process data on the display.
    Check Ethernet cable connections and switch/router status. Verify IP address configuration and firewall settings. Test with a known-good cable and check the network adapter status in Device Manager.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7260-1DA20-0BX6?

    This panel PC operates on a 24 V DC power supply. Ensure the power source is stable and within the specified voltage tolerance to prevent system faults.

    What touch technology does the IPC277D use?

    The 6AV7260-1DA20-0BX6 uses projected capacitive (PCT) multi-touch technology, supporting up to 5 simultaneous touch points. This allows for gesture-based interaction such as pinch-to-zoom.

    Is this panel PC compatible with Siemens WinCC software?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC and WinCC flexible runtime software, as well as other Windows-based SCADA and visualization applications.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7260-1DA20-0BX6 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial environments.

    Can the operating system be reinstalled or recovered on this panel PC?

    Yes, Siemens provides a recovery medium (USB or DVD) for the SIMATIC IPC277D that allows the factory operating system image to be restored. The recovery process is documented in the IPC277D operating instructions.

    Troubleshooting

    Display remains blank after power is applied

    Check that the 24 V DC supply voltage is present and within tolerance at the power connector. Verify the power LED status indicator on the unit. Measure voltage at the internal power input terminals.

    Confirm the power supply output is stable at 24 V DC. If the supply is correct but the display remains off, check the internal fuse and power distribution board. A failed backlight inverter or display panel may require component-level repair or replacement.

    Touch screen does not respond to input

    Determine whether the issue is with the touch overlay or the software. Test by connecting a USB mouse to verify if the OS is responsive. Check Device Manager for touch controller driver errors.

    Restart the touch driver service or reboot the panel PC. Recalibrate the touch screen through the Windows control panel. If the hardware touch controller is faulty, the touch overlay assembly may need replacement.

    Panel PC fails to boot into Windows

    Observe the boot sequence on the display. Check for BIOS POST error messages. Attempt to boot from an external USB device to determine if the internal storage is the cause.

    Re-image the internal storage using the Siemens recovery medium. If the storage device (SSD or Compact Flash) is physically faulty, replace it with a compatible unit and restore the OS image.

    Ethernet communication to PLC is intermittent or lost

    Check the Ethernet cable and connector for physical damage. Verify the IP address configuration in Windows Network Settings. Use the ping command to test connectivity to the PLC or network gateway.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings if incorrect. Update the network adapter driver if outdated. If the onboard NIC is faulty, a USB-to-Ethernet adapter can serve as a temporary workaround.

    WinCC runtime application crashes repeatedly

    Review the Windows Event Viewer Application log for error details related to the WinCC process. Check available disk space and RAM usage. Verify the WinCC license dongle or software license is present and valid.

    Free up disk space if storage is near capacity. Reinstall or repair the WinCC runtime installation. Ensure the WinCC project version matches the installed runtime version. Reactivate or replace the software license if it has expired or become corrupted.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart