The Siemens 6AV7260-1AA10-0BX5 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC product line. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a touch-enabled display with an embedded PC architecture. This unit is built to meet the demanding requirements of continuous industrial operation and integrates seamlessly into Siemens automation environments.
The IPC277D features a 15-inch widescreen TFT display with a resistive touch interface and a resolution of 1024 x 768 pixels. It is powered by an Intel Atom processor and runs Windows Embedded Standard 7 or Windows Embedded Compact 7, depending on the variant. The unit provides multiple communication interfaces including PROFINET, USB, and serial ports, and supports integration with SIMATIC WinCC and other Siemens HMI software platforms. It is designed for panel mounting with an IP65-rated front face, providing protection against dust and water ingress in the operator area.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine tool applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its fanless design options and robust construction make it suitable for environments where reliability and low maintenance are critical. The combination of PC functionality with HMI software compatibility makes it a versatile platform for visualization, data logging, and process monitoring tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 60 W |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interfaces | 2x PROFINET (RJ45), 4x USB 2.0, 1x RS-232 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100001
- Loss of communication to PLC or controller via PROFINET connection
Check PROFINET cable connections and network switch. Verify IP address configuration in WinCC or HMI project settings. Confirm PLC is in RUN mode. - Event ID: 110001
- Runtime software (WinCC flexible or WinCC RT) has stopped unexpectedly
Restart the runtime application. Check for corrupted project files and reload the HMI project. Verify sufficient RAM and storage space are available. - Event ID: 120001
- Touchscreen input not responding or calibration error detected
Recalibrate the touchscreen via the Windows control panel or SIMATIC HMI configuration tool. If unresponsive, check the touch controller ribbon cable connection internally. - Event ID: 130001
- Operating system boot failure or Windows Embedded startup error
Attempt a controlled restart. If the issue persists, restore the OS image using the Siemens recovery partition or a USB recovery medium. - Event ID: 140001
- Internal storage (CompactFlash or SSD) read/write error or low disk space warning
Check available disk space and delete unnecessary files or logs. If hardware failure is suspected, replace the internal storage medium with a compatible Siemens-approved device. - Event ID: 150001
- 24 V DC supply voltage out of tolerance or power interruption detected
Measure the supply voltage at the power connector. Ensure the supply is stable within the 24 V DC nominal range (typically 19.2 V to 28.8 V). Check power supply unit and cabling. - Event ID: 160001
- CPU or system temperature exceeded operating threshold
Check ambient temperature and ensure adequate ventilation around the panel. Clean any dust from ventilation slots. Verify the panel is not installed in a location exceeding the rated operating temperature of 50 °C.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D (6AV7260-1AA10-0BX5) run?
The IPC277D runs Windows Embedded Standard 7 (WES7) in this variant. It supports Siemens SIMATIC WinCC Runtime and WinCC flexible Runtime for HMI applications.
What is the supply voltage for the 6AV7260-1AA10-0BX5?
This unit operates on a 24 V DC supply voltage. The typical operating range is 19.2 V to 28.8 V DC.
Is the 6AV7260-1AA10-0BX5 compatible with SIMATIC WinCC?
Yes, the IPC277D is fully compatible with SIMATIC WinCC Runtime Advanced and WinCC flexible Runtime, making it suitable for use as a visualization station in Siemens automation systems.
What communication interfaces are available on this Panel PC?
The unit provides two PROFINET (RJ45) ports, four USB 2.0 ports, and one RS-232 serial interface, enabling connectivity to PLCs, peripherals, and network infrastructure.
What is the front panel protection rating of the IPC277D?
The front panel of the IPC277D carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial control panels.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the supply is within the 19.2 V to 28.8 V range. Check if the power LED indicator is illuminated.
If voltage is correct but display remains off, attempt a hard reset by holding the power button. If the backlight has failed, the display assembly may require replacement. Check internal fuse if no power LED is present.
Touchscreen does not respond to input or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware failure by attempting to use a USB mouse to navigate the OS. If mouse input works, the touch controller is likely miscalibrated.
Recalibrate the touchscreen through the Windows Embedded control panel under Tablet PC Settings. If calibration does not resolve the issue, inspect the touch controller ribbon cable connection or replace the touch overlay assembly.
HMI runtime application fails to start or crashes on startup
Check the Windows Event Viewer for application error logs. Verify that the HMI project files are intact and that sufficient free disk space exists on the internal storage medium.
Reload the HMI project from a backup source. If the OS is corrupted, restore the system image using the Siemens recovery partition or a USB recovery drive. Ensure the correct WinCC Runtime version is installed for the project.
PROFINET communication loss to the connected PLC
Ping the PLC IP address from the IPC277D to verify network connectivity. Check the PROFINET cable and switch port. Review the IP address and subnet mask settings in the HMI project.
Replace the PROFINET cable if damaged. Reconfigure the IP address settings if there is a conflict. Ensure the PLC PROFINET interface is configured to accept the IPC277D as a communication partner with the correct device name.
Unit runs slowly or becomes unresponsive during operation
Check CPU and RAM utilization via Windows Task Manager. Identify any background processes consuming excessive resources. Check available disk space on the system drive.
Disable unnecessary startup programs and background services. Archive and delete old log files to free disk space. If performance issues persist, consider restoring the factory OS image to eliminate software bloat or corruption.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page