• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6646-1BA22-1NA0 SIMATIC KTP400 Basic
    Awaiting product image

    Siemens 6AV6646-1BA22-1NA0 SIMATIC KTP400 Basic

    € 961,00

    Reset
    Clear
    SKU: 6AV6646-1BA22-1NA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6646-1BA22-1NA0 is a SIMATIC KTP400 Basic panel belonging to the Basic Panel 2nd Generation family from Siemens. It is a compact 4-inch key and touch-operated HMI panel designed for straightforward machine-level visualization and operator control tasks. This unit provides a cost-effective entry-level HMI solution within the SIMATIC HMI portfolio, suitable for applications requiring a small-footprint display with basic functionality.

    The KTP400 Basic features a 4.3-inch widescreen TFT display with a resolution of 480 x 272 pixels and 64,000 colors, delivering clear process visualization. It is equipped with 4 configurable function keys and a resistive touch screen for operator input. Communication is handled via a PROFINET interface, enabling seamless integration into modern Ethernet-based automation networks. The panel is configured using Siemens WinCC Basic (TIA Portal) engineering software and supports a user memory of 10 MB for project data.

    The SIMATIC KTP400 Basic is widely deployed in machine building, packaging machinery, conveyor systems, and small-scale process automation where a compact and reliable operator interface is required. Its PROFINET connectivity makes it directly compatible with SIMATIC S7-1200 and S7-1500 PLCs, as well as other PROFINET-capable controllers. The panel's small form factor and portrait or landscape mounting options make it suitable for integration into control cabinets and machine panels with limited space.

    Technical Specifications

    Display Size 4.3 inch
    Display Resolution 480 x 272 pixels
    Display Colors 64,000 colors
    Display Type TFT widescreen
    Touch Technology Resistive touch screen
    Function Keys 4 configurable function keys
    Input/Operating Voltage 24 V DC
    Power Consumption 4.5 W (typical)
    Communication Interface PROFINET (RJ45)
    User Memory 10 MB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC Basic (TIA Portal)

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC could not be established or was interrupted during operation.
    Check PROFINET cable connections and network configuration. Verify PLC IP address settings match the HMI project configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Communication timeout between the HMI panel and the configured PLC controller.
    Check network integrity and switch/router status. Verify PROFINET device names and IP addresses are correctly assigned. Restart both the HMI and PLC if the issue persists.
    Event ID: 20000
    Project download failed or project data is corrupted on the panel.
    Re-download the project from TIA Portal to the panel. Ensure the TIA Portal version matches the firmware version of the panel. Check USB or PROFINET connection used for transfer.
    Event ID: 40000
    HMI panel firmware version is incompatible with the loaded project.
    Update the panel firmware to the version required by the TIA Portal project, or recompile the project using a compatible TIA Portal version and re-download.
    Event ID: 70000
    Internal device error detected on the HMI panel hardware.
    Perform a panel reset to factory defaults. If the error persists, the panel hardware may require repair or replacement.
    Event ID: 50000
    Tag or variable address in the project references an invalid or non-existent PLC data block or memory area.
    Review the HMI project in TIA Portal and verify all tag addresses correspond to valid PLC memory locations. Recompile and re-download the project after corrections.
    Event ID: 30000
    Operator panel display backlight failure or reduced brightness detected.
    Check the operating hours of the panel. If the backlight has failed, the panel display unit requires servicing or replacement of the backlight assembly.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC KTP400 Basic (6AV6646-1BA22-1NA0)?

    The KTP400 Basic communicates via PROFINET and is primarily designed for use with Siemens SIMATIC S7-1200 and S7-1500 PLCs. It can also communicate with other PROFINET-capable controllers when configured appropriately in TIA Portal.

    What engineering software is required to configure this panel?

    The 6AV6646-1BA22-1NA0 must be configured using Siemens WinCC Basic, which is included with TIA Portal. The panel is not compatible with WinCC flexible or older STEP 7 Classic software.

    What is the supply voltage for the KTP400 Basic panel?

    The panel operates on 24 V DC. Ensure the power supply is within the specified tolerance range to avoid damage or malfunction.

    Does the KTP400 Basic support data logging or recipe management?

    The KTP400 Basic supports basic recipe management and data logging functions within the limitations of WinCC Basic. Advanced functions available in higher-tier panels such as the Comfort series are not available on this panel.

    What is the front panel protection rating of the 6AV6646-1BA22-1NA0?

    The front face of the KTP400 Basic panel is rated IP65, making it suitable for installation in environments where dust and water jets may be present. The rear of the panel is rated IP20.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the required voltage tolerance. Inspect the power connector for loose or incorrect wiring.

    Correct the supply voltage if out of range. Re-seat or replace the power connector wiring. If voltage is correct and display remains blank, the panel backlight or internal power circuitry may require repair or unit replacement.

    HMI panel does not establish communication with the PLC

    Verify the PROFINET cable is connected to the correct RJ45 port on the panel. Check the IP address and PROFINET device name assigned to the panel in TIA Portal match the physical device settings. Use a network diagnostic tool to confirm the panel is visible on the network.

    Correct any IP address or device name mismatches in TIA Portal and re-download the project. Replace the PROFINET cable if a physical fault is suspected. Ensure the PLC is powered and in RUN mode.

    Touchscreen does not respond or responds inaccurately to input

    Check the screen surface for contamination, moisture, or physical damage. Resistive touch screens can be affected by dirt or pressure applied at the edges. Verify the touch calibration has not been disrupted.

    Clean the screen surface with a soft, dry cloth. Perform a touch screen recalibration through the panel's Start Center menu. If inaccurate response persists after calibration, the touch panel overlay may require replacement.

    Project download from TIA Portal fails or is interrupted

    Check the PROFINET or USB connection between the engineering PC and the panel. Verify that the TIA Portal project version is compatible with the panel firmware version. Confirm the panel is in transfer mode before initiating the download.

    Switch the panel to transfer mode via the Start Center. Update panel firmware if a version mismatch is detected. Use a direct point-to-point PROFINET connection rather than a network switch to eliminate network-related transfer issues.

    Panel repeatedly restarts or enters an error loop after project load

    The loaded project may contain configuration errors or reference invalid PLC tags. Check the panel diagnostics buffer in TIA Portal for specific event IDs. Verify that the project was compiled without errors before downloading.

    Recompile the TIA Portal project, resolve all errors and warnings, and re-download to the panel. If the panel cannot be accessed, perform a factory reset via the Start Center and re-download a verified project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart