• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6646-1BA22-1AA1 SIMATIC KTP400 Basic
    Awaiting product image

    Siemens 6AV6646-1BA22-1AA1 SIMATIC KTP400 Basic

    € 863,00

    Reset
    Clear
    SKU: 6AV6646-1BA22-1AA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6646-1BA22-1AA1 is a SIMATIC KTP400 Basic Panel, part of the SIMATIC Basic Panel series from Siemens. It is a compact human-machine interface (HMI) device featuring a 4-inch widescreen TFT display with integrated key and touch operation. This panel is designed for straightforward visualization and operator control tasks in machine-level automation applications.

    The KTP400 Basic panel offers a 4" widescreen TFT display with a resolution of 480 x 272 pixels and 64,000 colors, providing clear and readable process visualization. It supports both touch and key operation through 4 configurable function keys, allowing flexible interaction modes. Communication is handled via a PROFINET interface (RJ45), enabling integration into modern Ethernet-based automation networks. The panel is configured using Siemens TIA Portal with WinCC Basic engineering software, and supports a project memory of 10 MB. Operating voltage is 24 V DC, and the unit carries CE and UL certifications.

    The SIMATIC KTP400 Basic is widely used in small to medium-sized machinery across manufacturing, packaging, food and beverage, and building automation industries. Its compact 4-inch form factor makes it suitable for installation in confined control cabinet doors or machine panels where space is limited. The combination of touch and key operation makes it adaptable to environments where gloved operation or dedicated function key access is required.

    Technical Specifications

    Display Size 4 inch (widescreen)
    Display Resolution 480 x 272 pixels
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touch screen
    Function Keys 4 configurable function keys
    Input/Operating Voltage 24 V DC
    Power Consumption 4.5 W (typical)
    Communication Interface PROFINET (RJ45, 10/100 Mbit/s)
    Project Memory 10 MB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Panel Cutout 122 x 95 mm
    Certifications CE, UL, cULus
    Engineering Software TIA Portal with WinCC Basic

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup. The loaded project is incompatible with the panel firmware version.
    Re-download the project from TIA Portal ensuring the firmware version matches the configured HMI device version. Update panel firmware if necessary.
    Event ID: 20000
    Communication connection to PLC lost or not established. PROFINET connection is interrupted.
    Check PROFINET cable and RJ45 connector integrity. Verify IP address configuration on both the panel and PLC. Check network switch status.
    Event ID: 40000
    Tag read/write error. A configured tag cannot be read from or written to the connected controller.
    Verify the PLC data block and tag addresses in TIA Portal. Ensure the PLC program is running and the DB is not write-protected.
    Event ID: 70000
    Project download failed. Transfer to the HMI panel was interrupted or unsuccessful.
    Check the PROFINET connection between engineering PC and panel. Ensure the panel is in transfer mode and no firewall is blocking the TIA Portal transfer.
    Event ID: 50000
    Internal device error. A hardware or firmware fault has been detected on the panel.
    Perform a factory reset via the Start Center (Control Panel). If the error persists, update the firmware or replace the panel.
    Event ID: 30000
    Alarm buffer overflow. The number of pending alarms exceeds the panel buffer capacity.
    Acknowledge and clear active alarms in the HMI runtime. Review alarm configuration in TIA Portal to reduce simultaneous alarm load.

    Frequently Asked Questions

    What communication interface does the KTP400 Basic (6AV6646-1BA22-1AA1) support?

    The KTP400 Basic supports one PROFINET interface via an RJ45 connector operating at 10/100 Mbit/s. It does not natively support PROFIBUS or MPI without additional hardware.

    Which engineering software is required to configure this panel?

    The 6AV6646-1BA22-1AA1 is configured using Siemens TIA Portal with the WinCC Basic engineering package. WinCC Comfort or Advanced licenses are not required for this panel.

    Is the KTP400 Basic compatible with S7-1200 and S7-1500 PLCs?

    Yes, the KTP400 Basic communicates natively with Siemens S7-1200 and S7-1500 PLCs via PROFINET. It can also communicate with S7-300 and S7-400 PLCs that have a PROFINET interface.

    What is the operating voltage of this HMI panel?

    The panel operates on 24 V DC. It is typically powered from a dedicated 24 V DC power supply unit within the control cabinet.

    Can the KTP400 Basic be operated with gloves?

    Yes, the panel supports operation via 4 physical function keys in addition to the resistive touch screen, making it suitable for use with gloves in industrial environments.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC supply voltage at the power connector on the rear of the panel. Check that polarity is correct and voltage is within the 20.4–28.8 V DC tolerance range.

    Correct the supply voltage or replace the 24 V DC power supply if out of range. If voltage is correct and display remains blank, the internal backlight or power supply board may be faulty and the panel should be repaired or replaced.

    Panel does not establish PROFINET connection to PLC

    Check the RJ45 cable and connector for physical damage. Verify the IP address, subnet mask, and device name configured on the panel match the settings in the TIA Portal project and PLC configuration.

    Replace the Ethernet cable if damaged. Reconfigure the IP address via the panel Start Center (Control Panel > Ethernet settings). Re-download the project from TIA Portal after correcting network parameters.

    Touch screen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Determine whether the issue is localized to a specific area of the screen or affects the entire display.

    Clean the touch surface with a soft, dry cloth. Perform a touch screen calibration via the Start Center (Control Panel > Touch Calibration). If the issue persists, the touch panel overlay may require replacement.

    Project download fails from TIA Portal

    Verify that the engineering PC and the HMI panel are on the same network subnet. Confirm the panel is in transfer mode (accessible via Start Center > Transfer). Check for firewall or antivirus software blocking TIA Portal communication.

    Set the panel to transfer mode manually via the Start Center. Disable firewall rules blocking TIA Portal on the engineering PC. Ensure the correct device IP address is entered in the TIA Portal download dialog.

    Runtime alarms are not displayed or alarm list is empty

    Check the alarm configuration in TIA Portal to confirm alarm tags are correctly linked to PLC data addresses. Verify the PLC connection is active and the relevant PLC bits are being set.

    Re-examine alarm tag connections in TIA Portal WinCC Basic. Re-download the project after corrections. Confirm PLC program logic is triggering the alarm bits as expected during testing.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart