• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6574-2AC00-2AF1 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6574-2AC00-2AF1 WinCC flexible 2008

    € 147,00

    Reset
    Clear
    SKU: 6AV6574-2AC00-2AF1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6574-2AC00-2AF1 is a software license for WinCC flexible 2008 Standard, part of Siemens' WinCC flexible engineering software family. This product provides a PC-based SCADA and HMI configuration environment used to create, configure, and commission visualization projects for Siemens HMI panels and operator stations. It belongs to the SIMATIC HMI software portfolio and is designed for use on standard Windows-based engineering workstations.

    WinCC flexible 2008 Standard supports configuration of a wide range of Siemens HMI devices including the TP, OP, MP, and Mobile Panel series. The software offers an integrated tag management system, alarm logging, trend displays, recipe management, and multi-language project support. It provides connectivity via MPI, PROFIBUS, PROFINET, and Ethernet interfaces, and supports integration with SIMATIC S7-300, S7-400, and S7-200 PLC families. The Standard edition supports projects with up to 2,048 process tags and includes simulation functionality for offline project testing.

    WinCC flexible 2008 Standard is used across manufacturing, process automation, and machine building industries where Siemens HMI panels are deployed. It is particularly suited for OEMs and system integrators developing machine-level visualization solutions for packaging machinery, conveyor systems, press lines, and similar industrial equipment. The software serves as the engineering tool for commissioning and maintaining HMI applications in both standalone and networked automation environments.

    Technical Specifications

    Software Version WinCC flexible 2008 Standard
    License Type Single-user license
    Maximum Process Tags 2,048
    Supported HMI Devices SIMATIC TP, OP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Communication Interfaces MPI, PROFIBUS, PROFINET, Ethernet
    Operating System Windows XP SP3, Windows Vista, Windows 7
    Simulation Integrated offline project simulation
    Language Support Multi-language project configuration
    Alarm Management Integrated alarm logging and display
    Recipe Management Supported
    Trend Display Supported
    Series/Product Family SIMATIC WinCC flexible 2008

    Common Error Codes and System Events

    Error 1920
    License not found or license server unreachable during software startup
    Verify that the license key (dongle or software license) is correctly installed. Use the Automation License Manager to check license status and transfer if necessary.
    Error 1722
    Installation error: Windows Installer package failure during WinCC flexible setup
    Ensure all prerequisites including .NET Framework and MSXML are installed. Run the installer as Administrator and check Windows Event Viewer for detailed error information.
    Error 2503 / 2502
    Installer access denied error during installation or uninstallation
    Run the installer with elevated Administrator privileges. Temporarily disable UAC if operating on Windows Vista or Windows 7 and retry the installation.
    Compiler Error
    Project compilation fails due to inconsistent tag references or missing device configuration
    Check the output window for specific tag or screen references causing the error. Verify all HMI device configurations are complete and all referenced tags exist in the tag table.
    Communication Error
    No connection established between WinCC flexible Runtime and the target PLC
    Verify communication settings including PLC address, subnet, and interface selection. Check physical connections and ensure the correct communication driver is installed and active.
    Transfer Error
    Project transfer to HMI panel fails during download
    Confirm the target HMI device is in Transfer mode. Verify the IP address or MPI/PROFIBUS address settings match the panel configuration. Check network or cable connections between the engineering PC and the HMI panel.
    Runtime License Missing
    WinCC flexible Runtime reports missing or invalid license on the HMI panel
    Use the Automation License Manager to verify and transfer the correct Runtime license to the target HMI device. Ensure the Runtime license matches the panel type and tag count.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2008 Standard?

    WinCC flexible 2008 Standard supports the full range of SIMATIC HMI panels including the TP 177, TP 277, OP 277, MP 277, MP 377, and Mobile Panel 177 and 277 series, among others.

    What is the maximum number of process tags supported in the Standard edition?

    The Standard edition of WinCC flexible 2008 supports up to 2,048 process tags per project.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP SP3, Windows Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues are likely without additional configuration or virtualization.

    Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects, though some manual rework may be required depending on the complexity of the project and the target HMI device.

    Does this license include WinCC flexible Runtime?

    No, the 6AV6574-2AC00-2AF1 is an engineering software license for project configuration only. A separate WinCC flexible Runtime license is required to execute the project on a PC-based operator station.

    Troubleshooting

    Software fails to start after installation and reports a license error

    Open the Automation License Manager and check whether a valid WinCC flexible 2008 Standard license is present and assigned to the local machine or connected dongle.

    Transfer the correct license using the Automation License Manager. If using a hardware dongle, ensure it is connected to a USB port and recognized by Windows before launching the software.

    Project transfer to HMI panel fails with a connection timeout

    Verify the communication settings in the project match the physical panel configuration, including IP address for Ethernet or node address for MPI/PROFIBUS connections.

    Set the HMI panel to Transfer mode manually via its Start Center. Confirm network cable integrity, correct interface selection in the transfer dialog, and that no firewall is blocking the connection.

    Compilation errors appear when building the project

    Review the compiler output window to identify which screens, tags, or scripts contain errors. Common causes include missing tag assignments, invalid data types, or references to deleted objects.

    Correct all flagged references in the tag table and screen editor. Ensure all HMI device settings are fully configured and that no placeholder or undefined tags remain in the project.

    WinCC flexible 2008 cannot be installed on the engineering PC

    Check Windows Event Viewer for installation error codes. Confirm that required prerequisites such as .NET Framework 2.0 or higher and MSXML 6.0 are installed and that the user account has Administrator privileges.

    Install all missing prerequisites before running the WinCC flexible setup. Disable antivirus software temporarily during installation and run the setup executable as Administrator.

    Simulation function does not reflect PLC data correctly

    The integrated simulator uses internal simulated tags and does not connect to a live PLC. Verify that the simulation is configured to use the correct tag values and that no external communication is expected during simulation.

    Use the simulation tag table to manually set input values for testing. For live PLC connectivity testing, use the actual Transfer and Runtime mode on a connected HMI panel rather than the PC simulator.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart