
Siemens 6AV6574-1AE14-4AA0 SIMATIC WinCC flexible 2008
€ 256,00
The Siemens 6AV6574-1AE14-4AA0 is a software license for SIMATIC WinCC flexible 2008, Siemens' engineering software platform for configuring and commissioning HMI (Human-Machine Interface) panels and visualization systems. This product belongs to the WinCC flexible 2008 family, which represents a scalable SCADA and HMI configuration environment designed for use with the full range of Siemens SIMATIC HMI hardware, from Micro Panels to multi-panel and PC-based systems. The specific variant encoded in this part number corresponds to a runtime or engineering edition with defined tag count and feature set.
WinCC flexible 2008 provides a comprehensive engineering environment with a project-oriented structure, enabling users to configure screens, alarms, tags, scripts, and communication connections within a single unified interface. The software supports a wide range of communication drivers and protocols, including PROFIBUS, PROFINET, MPI, and Industrial Ethernet, allowing seamless integration with SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs. It includes features such as faceplates, library management, multi-language project support, and integrated simulation for offline testing. The platform also supports structured tag management, alarm logging, trend displays, and recipe management.
SIMATIC WinCC flexible 2008 is widely used in manufacturing, process automation, energy management, and machine building industries. It is particularly suited for OEMs and system integrators who need a consistent engineering tool across a broad range of HMI hardware targets. Typical applications include machine control panels, production line visualization, packaging machinery, and plant-level monitoring systems where reliable and scalable HMI configuration is required.
Technical Specifications
| Software Family | SIMATIC WinCC flexible 2008 |
|---|---|
| Software Type | HMI Engineering / Configuration Software |
| License Type | Single-user license |
| Compatible HMI Hardware | SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs |
| Compatible PLCs | SIMATIC S7-200, S7-300, S7-400, S7-1200, S7-1500 |
| Communication Protocols | PROFIBUS, PROFINET, MPI, Industrial Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 (32/64-bit) |
| Installation Medium | DVD / Electronic license |
| Language Support | Multi-language project configuration |
| Series | WinCC flexible 2008 |
Common Error Codes & System Events
- Event ID: 1000000
- General runtime error during project execution, often caused by corrupted project data or incompatible runtime version.
Restart the WinCC flexible runtime, verify project compatibility with the installed runtime version, and re-download the project to the HMI device. - Event ID: 110000
- Communication connection to the PLC could not be established or was interrupted.
Check physical network connections, verify IP address or PROFIBUS address settings, confirm PLC is in RUN mode, and check communication driver configuration in the project. - Event ID: 040000
- Tag read/write error — the configured tag address could not be accessed on the connected controller.
Verify the tag address exists in the PLC program, check data type consistency between HMI tag and PLC variable, and confirm the communication connection is active. - Event ID: 070000
- Alarm logging error — the alarm archive could not be written, possibly due to insufficient storage space or a corrupted archive file.
Check available storage on the HMI device, clear or archive old alarm logs, and verify the alarm logging configuration in the WinCC flexible project. - Event ID: 080000
- Recipe data error — recipe records could not be read from or written to the configured storage location.
Verify the recipe storage path is accessible, check that the storage medium is not write-protected, and confirm recipe tag addresses are correctly mapped in the project. - Event ID: 050000
- Script execution error — a configured VB script encountered a runtime error during execution.
Review the script logic in the WinCC flexible engineering environment, check for division by zero or null reference errors, and test the script using the integrated simulator. - Event ID: 020000
- License not found or license count exceeded — the runtime license for the configured tag count or feature set is missing or invalid.
Verify the correct license is installed using the Siemens Automation License Manager (ALM), ensure the license matches the required tag count, and transfer the license to the target device if necessary. - Event ID: 060000
- Trend display error — historical trend data could not be retrieved from the data log archive.
Check the data log configuration in the project, verify the archive storage path, and ensure sufficient memory is available on the HMI device for data logging.
Frequently Asked Questions
Which Siemens PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, S7-1200, and S7-1500 PLCs, as well as SIMATIC 505 and third-party controllers via OPC. Communication is established via MPI, PROFIBUS, PROFINET, or Industrial Ethernet depending on the hardware configuration.
What operating systems does SIMATIC WinCC flexible 2008 support for the engineering station?
WinCC flexible 2008 is compatible with Windows XP (SP3), Windows Vista, and Windows 7 in both 32-bit and 64-bit editions. It is not officially supported on Windows 10 or later without compatibility workarounds.
Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, not all objects and scripts are migrated automatically, and manual rework is typically required after migration.
What is the Automation License Manager and is it required for this software?
The Siemens Automation License Manager (ALM) is a license management utility required to activate and manage WinCC flexible 2008 licenses. The license key associated with part number 6AV6574-1AE14-4AA0 must be registered and activated through ALM before the software can be used.
Does WinCC flexible 2008 support simulation without a connected HMI device?
Yes, WinCC flexible 2008 includes an integrated simulator that allows engineers to test and validate HMI projects on a PC without requiring a physical HMI panel or PLC connection, which is useful for offline development and testing.
Troubleshooting
WinCC flexible 2008 fails to start or displays a license error on launch
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and not expired or transferred. Verify the license matches the installed software version and tag count.
Transfer the correct license to the engineering PC using ALM. If the license dongle or certificate is missing, contact Siemens license support. Ensure the ALM software itself is up to date.
Project cannot be transferred to the HMI panel — transfer connection fails
Check the transfer settings in WinCC flexible (Edit > Transfer Settings) and verify the correct interface (USB, Ethernet, or MPI/PROFIBUS) and address are configured. Confirm the HMI panel is in Transfer mode.
Set the HMI panel to Transfer mode manually via the Start Center or Control Panel on the device. Verify firewall settings on the PC are not blocking the transfer port, and confirm the network cable or USB connection is functional.
Communication between HMI and PLC is lost during runtime
Check the alarm window on the HMI for communication error events. Verify the PLC is powered and in RUN mode. Check the physical Ethernet or PROFIBUS cable connections and confirm the PLC IP or bus address matches the project configuration.
Restore the physical connection and confirm address settings in both the PLC hardware configuration and the WinCC flexible communication driver settings. Restart the HMI runtime if the connection does not recover automatically.
Installed WinCC flexible 2008 software does not recognize or open existing project files
Check the project file version against the installed software version. Projects created in a newer service pack or version of WinCC flexible may not open in an older installation.
Install the latest available service pack for WinCC flexible 2008 from the Siemens support portal. If the project was created in a newer version, upgrade the engineering software to match or request a downgraded export from the project creator.
Alarm events are not being logged or historical alarms are missing from the alarm view
Check the alarm logging configuration in the WinCC flexible project to confirm logging is enabled and the archive storage path is correctly defined. Verify available storage space on the HMI device.
Reconfigure the alarm archive storage path to a valid location with sufficient free space. Clear old archive files if storage is full. Re-download the project to the HMI and verify alarm logging resumes correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page



