• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA41-0BB4 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA41-0BB4 SIMATIC MP 370

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6446-1AA41-0BB4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA41-0BB4 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 12-inch TFT display and is part of Siemens' high-performance Multi Panel series, which bridges the gap between standard operator panels and full PC-based systems. It is intended for use as a stationary operator interface in machine and plant automation.

    The MP 370 (6AV6446-1AA41-0BB4) is equipped with a 12" TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It runs on a Windows CE-based operating system and is compatible with WinCC flexible runtime software for configuration and visualization. The panel provides multiple communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling integration into a wide range of Siemens and third-party control architectures. It features a robust industrial-grade housing suitable for front-panel mounting with an IP65 protection rating on the front face.

    The SIMATIC MP 370 is widely deployed in machine tool automation, packaging machinery, automotive manufacturing lines, and process plant control rooms. Its combination of a large color touch display, flexible communication options, and compatibility with SIMATIC S7 PLCs makes it well suited for applications requiring detailed process visualization, recipe management, and alarm handling. The panel is also used in water treatment, energy management, and conveyor system applications where a reliable and versatile HMI interface is required.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors (TFT)
    Touch Technology Resistive touch screen
    Operating System Windows CE
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 30 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), RS-232, RS-422/485
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Front panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC Multi Panel MP 370

    Common Error Codes & System Events

    Event ID: 10000
    Connection to the PLC could not be established or was interrupted during runtime.
    Check MPI/PROFIBUS/Ethernet cable connections and verify PLC address settings in the WinCC flexible project. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Communication timeout between the HMI panel and the configured PLC controller.
    Verify network configuration, check baud rate settings, and confirm the PLC station address matches the HMI project configuration.
    Event ID: 20000
    Project download failed or project data is corrupted on the panel.
    Re-transfer the WinCC flexible project to the panel using ProSave or WinCC flexible. Check available memory on the panel before transfer.
    Event ID: 40000
    System memory low — available RAM on the panel is critically low during runtime.
    Reduce the number of active screens, limit open trend views, and check for memory leaks in scripts. Consider restarting the panel.
    Event ID: 50000
    Internal panel error or hardware fault detected during self-diagnostics.
    Perform a panel restart. If the fault persists, back up the project and perform a factory reset via the Control Panel. Contact Siemens support if unresolved.
    Event ID: 60000
    Backup battery low or battery failure detected.
    Replace the internal backup battery (CR2032 or equivalent as specified in the device manual) to prevent loss of time/date settings and retentive data.
    Event ID: 70000
    Screen saver or display backlight fault — display does not illuminate correctly.
    Check backlight settings in the Control Panel. If the backlight has failed, the display unit or backlight inverter may require replacement.
    Event ID: 30000
    Tag or variable limit violation — a monitored process value has exceeded its configured high or low limit.
    Acknowledge the alarm in the HMI alarm view. Investigate the corresponding process value in the PLC and correct the process condition causing the limit violation.

    Frequently Asked Questions

    Which PLC families is the SIMATIC MP 370 compatible with?

    The MP 370 is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and also supports Ethernet-based communication with S7 controllers. It can also be configured for use with third-party PLCs via serial interfaces using appropriate drivers in WinCC flexible.

    What software is required to configure and program this panel?

    The MP 370 is configured using Siemens WinCC flexible (2004 or later versions). Projects are transferred to the panel via Ethernet, MPI, or USB using the ProSave tool or directly from WinCC flexible.

    What is the input voltage requirement for the 6AV6446-1AA41-0BB4?

    The panel requires a 24 V DC supply voltage. Ensure the power supply can deliver sufficient current to meet the panel's maximum power consumption of approximately 30 W.

    Does this panel support recipe management and data logging?

    Yes, the SIMATIC MP 370 supports recipe management, trend displays, alarm logging, and data logging functions when configured with WinCC flexible runtime.

    What is the front panel protection rating of this unit?

    The front face of the MP 370 achieves an IP65 protection rating, making it suitable for installation in control cabinet doors where it may be exposed to dust and water spray.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply polarity is correct and that the supply can deliver adequate current. Inspect the backlight by shining an external light on the screen to check for faint image.

    If supply voltage is correct and the backlight has failed, the display or backlight inverter assembly requires replacement. If no voltage is present, check the external power supply and wiring. Replace the internal fuse if blown.

    Panel fails to communicate with the S7 PLC via MPI or PROFIBUS

    Verify the MPI/PROFIBUS cable is correctly connected and terminated. Check the station address configured on the panel matches the project settings. Use a PROFIBUS diagnostic tool to check bus integrity and baud rate.

    Correct any address conflicts, ensure proper bus termination resistors are in place at both ends of the bus, and re-download the HMI project if configuration settings were changed.

    Touch screen does not respond accurately or is misaligned

    Attempt to recalibrate the touch screen via the Siemens Control Panel on the panel (Start > Settings > Control Panel > Touch). Check for physical damage or contamination on the screen surface.

    Perform a touch screen recalibration. If calibration does not resolve the issue, clean the screen surface with a soft cloth. If the touch layer is damaged, the touch screen assembly requires replacement.

    Panel repeatedly reboots or freezes during operation

    Check the supply voltage for stability and ripple. Review the WinCC flexible project for script errors or excessive memory usage. Check the operating temperature of the installation environment.

    Ensure the 24 V DC supply is stable and within specification. Optimize the WinCC flexible project to reduce memory load. If the panel continues to reboot, perform a factory reset and re-transfer the project. Persistent hardware faults may require panel repair or replacement.

    Project transfer from WinCC flexible fails or is interrupted

    Check the communication cable (Ethernet or MPI) between the engineering PC and the panel. Verify that the panel is in transfer mode and that the correct interface is selected in WinCC flexible's transfer settings.

    Restart the panel in transfer mode by accessing the Control Panel loader screen. Ensure firewall or antivirus software on the PC is not blocking the transfer. Try an alternative cable or interface if the problem persists.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart