• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA41-0BB5 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA41-0BB5 SIMATIC MP 370

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6446-1AA41-0BB5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA41-0BB5 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding machine-level visualization and operator control tasks. This panel is part of the MP 370 series, which offers a 12-inch display and is intended for use as a high-performance operator interface in industrial automation environments. It is manufactured by Siemens and integrates seamlessly within the SIMATIC automation ecosystem.

    The MP 370 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports both touch and key operation, providing flexible interaction options for operators. It runs on Windows CE and is configured using Siemens WinCC flexible engineering software, supporting a wide range of communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP). The panel includes onboard flash memory for project storage, supports USB ports for peripherals and data transfer, and is rated for continuous industrial operation with a robust front panel design.

    The SIMATIC MP 370 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and chemical plant environments where a reliable and feature-rich HMI is required at the machine or cell level. Its combination of touch and function key operation makes it suitable for applications requiring both graphical navigation and direct key-based control. The panel's compatibility with SIMATIC S7 PLCs and support for multiple fieldbus protocols makes it a versatile choice for complex automation systems.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Display Colors 256 colors
    Touch Technology Resistive touch screen with function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 30 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), RS-422/485
    Operating System Windows CE
    Memory 12 MB flash (user memory)
    USB Ports 2 x USB (Type A)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC MP 370

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected during project download or startup; project data may be corrupt or incompatible with the panel firmware version.
    Re-download the project using WinCC flexible. Ensure the firmware version on the panel matches the version used during project compilation.
    Event ID: 10001
    Communication connection to the PLC has been lost or cannot be established.
    Check MPI/PROFIBUS/Ethernet cabling and connector integrity. Verify PLC address settings and communication parameters in the project configuration.
    Event ID: 20000
    System memory low; available RAM for runtime operation is critically low.
    Reduce the number of active screens or objects. Optimize the project to reduce memory usage and restart the panel.
    Event ID: 40000
    Tag read/write error; a configured variable could not be read from or written to the connected controller.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts.
    Event ID: 50000
    Recipe data error; a recipe record could not be read or written correctly.
    Check recipe configuration in WinCC flexible. Verify that the recipe data storage location (flash or memory card) is accessible and not full.
    Event ID: 70000
    Alarm buffer overflow; the number of pending alarms has exceeded the buffer capacity.
    Acknowledge and clear existing alarms. Review alarm configuration to reduce simultaneous alarm generation and increase buffer size if possible in the project settings.
    Event ID: 110000
    Backup/restore operation failed; data could not be backed up to or restored from the memory card.
    Check that the memory card is correctly inserted and not write-protected. Reformat the card if necessary and retry the backup/restore operation.

    Frequently Asked Questions

    What communication interfaces are supported by the 6AV6446-1AA41-0BB5?

    The MP 370 supports MPI, PROFIBUS DP, and Ethernet (TCP/IP) interfaces, as well as RS-422/485 serial communication, allowing connection to a wide range of Siemens and third-party controllers.

    Which engineering software is used to configure this panel?

    The SIMATIC MP 370 is configured using Siemens WinCC flexible software. The project must be compiled with a compatible version of WinCC flexible and downloaded to the panel via Ethernet, MPI, or USB.

    Is the 6AV6446-1AA41-0BB5 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and can also communicate with S7 controllers over Ethernet using the TCP/IP protocol.

    What is the front panel protection rating of this HMI?

    The front panel of the MP 370 is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial control cabinet doors.

    Can the firmware on the MP 370 be updated in the field?

    Yes, the firmware can be updated using the ProSave tool from Siemens, transferring the firmware image via Ethernet or MPI connection to the panel.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector. Verify that the supply is within the specified range and that the connector is firmly seated.

    Restore correct 24 V DC supply. If voltage is correct and display remains blank, the internal backlight or power supply board may have failed and the unit should be sent for repair or the backlight replaced.

    Panel does not communicate with the PLC

    Verify the communication cable type and wiring for the selected interface (MPI, PROFIBUS, or Ethernet). Check the PLC address and baud rate settings configured in the WinCC flexible project against the actual PLC settings.

    Correct any wiring faults or address mismatches. Replace the communication cable if damaged. Ensure the PLC is in RUN mode and that the correct communication driver is selected in the project.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Attempt to recalibrate the touchscreen using the panel's Control Panel settings accessible during startup.

    Clean the touch surface with a soft, dry cloth. Perform a touchscreen recalibration via the Windows CE Control Panel. If the issue persists, the touch overlay may need replacement.

    Project download fails or times out

    Verify the Ethernet or MPI connection between the engineering PC and the panel. Check that the panel is in transfer mode and that no firewall or network settings are blocking the connection.

    Switch the panel to transfer mode manually via the Start Center. Disable any PC firewall temporarily during download. Ensure the correct IP address or MPI address is configured in the WinCC flexible transfer settings.

    Panel freezes or restarts unexpectedly during operation

    Check for overheating by verifying the ambient temperature and ensuring adequate ventilation around the panel. Review the project for memory-intensive operations or script errors that could cause runtime instability.

    Ensure the installation environment is within the 0 to 50 °C operating temperature range. Optimize the WinCC flexible project to reduce CPU and memory load. Update the panel firmware to the latest available version to resolve known runtime issues.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart