• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA41-0BB3 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA41-0BB3 SIMATIC MP 370

    € 4.076,00

    Reset
    Clear
    SKU: 6AV6446-1AA41-0BB3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA41-0BB3 is a Multi Panel (MP 370) belonging to the SIMATIC HMI Multi Panel series by Siemens. It is a high-performance operator panel designed for demanding visualization and control tasks in industrial automation environments. This unit features a 12-inch TFT display and runs on the Windows CE operating system, making it suitable for complex HMI applications.

    The MP 370 (6AV6446-1AA41-0BB3) is equipped with a touch-sensitive screen interface and supports a wide range of communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling seamless integration into existing Siemens automation networks. It offers substantial onboard memory for project storage and runtime data, and supports configuration via Siemens WinCC flexible engineering software. The panel is built to industrial standards with a robust front panel rated to IP65, ensuring protection against dust and water ingress in harsh production environments.

    The SIMATIC MP 370 is widely deployed in manufacturing, automotive, food and beverage, chemical processing, and machine tool industries. Its combination of a large display, versatile communication options, and Windows CE-based runtime environment makes it well suited for applications requiring complex process visualization, recipe management, alarm logging, and trend display on the factory floor.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT color LCD
    Display Colors 256 colors
    Touch Technology Resistive touch screen
    Operating System Windows CE
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 30 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), RS-422/485
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. The connection to the configured communication partner has been lost.
    Check the communication cable and connector integrity. Verify MPI/PROFIBUS address settings and baud rate configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    No connection to the PLC. The HMI cannot establish a connection to the configured PLC at startup.
    Verify network address settings on both the HMI and PLC. Check physical wiring and termination resistors on PROFIBUS. Confirm the PLC project is loaded and running.
    Event ID: 20000
    Tag read error. The HMI was unable to read the value of a configured process tag from the PLC.
    Check that the tag address configured in WinCC flexible matches the actual PLC data block or memory address. Verify PLC program is running and the address exists.
    Event ID: 20001
    Tag write error. The HMI failed to write a value to the configured PLC tag.
    Confirm the PLC memory area is not write-protected. Check tag address configuration and ensure the PLC is in a state that accepts write commands.
    Event ID: 40000
    Project loading error. The HMI runtime was unable to load the configured project file from internal memory.
    Transfer the project again from the engineering PC using WinCC flexible. Check available storage memory on the panel and ensure the project file is not corrupted.
    Event ID: 50000
    System memory low. Available RAM on the HMI panel is critically low, which may cause runtime instability.
    Reduce the number of simultaneously active screens or objects. Optimize the project by reducing image sizes and the number of active tags. Restart the panel to clear memory.
    Event ID: 60000
    Internal device error or hardware fault detected by the panel self-diagnostic routine.
    Perform a panel restart. If the error persists, back up the project and perform a factory reset. Contact Siemens technical support or arrange for hardware inspection and repair.

    Frequently Asked Questions

    What is the display size and type of the 6AV6446-1AA41-0BB3?

    The 6AV6446-1AA41-0BB3 features a 12-inch TFT color LCD with a resistive touch screen interface supporting 256 colors.

    What communication interfaces are supported by the MP 370?

    The MP 370 supports MPI, PROFIBUS DP, Ethernet (TCP/IP), and RS-422/485 serial interfaces, allowing integration with a wide range of Siemens PLCs and third-party controllers.

    Which engineering software is used to configure the SIMATIC MP 370?

    The MP 370 is configured using Siemens WinCC flexible, which allows project creation, tag configuration, alarm management, and project transfer to the panel.

    What is the supply voltage for the 6AV6446-1AA41-0BB3?

    The panel operates on a 24 V DC supply voltage.

    Is the MP 370 compatible with SIMATIC S7 PLCs?

    Yes, the MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and also supports S7 communication over Ethernet with appropriate configuration.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Measure voltage at the panel connector. Inspect the internal fuse if accessible.

    Ensure the power supply is correctly wired and providing stable 24 V DC. If voltage is correct and display remains blank, the internal power supply board or backlight inverter may have failed and the unit should be sent for repair.

    Touch screen does not respond or responds inaccurately

    Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the screen surface.

    Perform a touch screen calibration via the Windows CE control panel or the SIMATIC HMI service menu. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, the touch panel overlay may need replacement.

    HMI cannot connect to PLC via PROFIBUS

    Verify the PROFIBUS cable is correctly connected and terminated at both ends. Check that the MPI/PROFIBUS address on the HMI matches the configured communication partner address in the project.

    Correct any address conflicts, ensure termination resistors are active only at the physical ends of the bus, and confirm the baud rate matches across all devices. Re-transfer the project if communication parameters were changed.

    Project transfer from WinCC flexible fails

    Check the transfer connection type (Ethernet or MPI/PROFIBUS). Ensure the panel is in Transfer mode and the PC firewall or antivirus is not blocking the WinCC flexible transfer application.

    Set the panel to Transfer mode via the Start Center. Verify the IP address or MPI address settings match in WinCC flexible transfer settings. Disable firewall temporarily during transfer if needed and retry.

    Panel freezes or restarts unexpectedly during operation

    Check for power supply instability or voltage drops below 24 V DC. Review the alarm and event log on the panel for any system memory or runtime errors preceding the freeze.

    Stabilize the power supply and ensure adequate current capacity. Optimize the HMI project to reduce memory usage. If the problem persists, perform a firmware update or factory reset and reload the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart