Siemens 6AV6382-2FA08-0AX0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6382-2FA08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is designed for use with the full range of Siemens operator panels and multi-panel devices.
WinCC flexible 2008 offers a comprehensive set of engineering tools for creating HMI projects, including drag-and-drop screen design, tag management, alarm logging, trend displays, and recipe management. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes a scalable licensing model with editions ranging from Micro to Advanced, supporting projects from small single-panel installations up to complex multi-panel distributed systems. The software runs on standard Windows operating systems and integrates with the SIMATIC automation environment.
WinCC flexible 2008 is widely used in manufacturing automation, process control, packaging machinery, and building automation applications. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and energy, where reliable HMI visualization and operator interaction are required. The software's compatibility with the broad Siemens SIMATIC panel portfolio makes it a standard engineering tool for system integrators and OEMs working within the Siemens automation ecosystem.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| License Type | Single-user license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported Operating Systems | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Engineering Editions | Micro, Compact, Standard, Advanced |
| Supported Panel Types | SIMATIC HMI Panels, Multi Panels, Mobile Panels |
| Alarm Management | Included |
| Recipe Management | Included |
| Trend Display | Included |
| Tag Limit (Advanced Edition) | Up to 100,000 tags |
| Certifications | CE |
| Language Support | Multi-language project support |
Common Error Codes and System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct Runtime version is installed on the panel. Verify project compatibility with the panel firmware version and re-download the project. - Event ID: 2001
- Communication error — Connection to the configured PLC could not be established.
Verify PLC address settings, check physical communication cables, and confirm that the correct communication driver is configured in the project. - Event ID: 3010
- Tag read/write error — A configured tag could not be read from or written to the PLC.
Check that the tag address exists in the PLC program, verify data type consistency, and confirm the PLC is in RUN mode. - Event ID: 4000
- License error — No valid license found for WinCC flexible on this PC.
Install the correct license using the Siemens Automation License Manager (ALM). Ensure the license matches the installed software edition. - Event ID: 5001
- Project transfer error — Project could not be transferred to the target HMI panel.
Check the transfer connection (USB, Ethernet, or MPI), ensure the panel is in Transfer mode, and verify that the project is compiled without errors before transfer. - Event ID: 6002
- Alarm buffer overflow — The alarm buffer on the HMI panel has reached its maximum capacity.
Acknowledge and clear existing alarms, increase the alarm buffer size in the project settings, or configure alarm archiving to an external storage medium. - Event ID: 7005
- Recipe data error — Recipe data could not be read from or written to the configured data medium.
Check the recipe configuration, verify that the storage medium (memory card or internal flash) is accessible and has sufficient free space. - Event ID: 8010
- Screen navigation error — A configured screen change could not be executed due to a missing or incorrectly linked screen.
Open the project in WinCC flexible engineering software, verify all screen navigation links, recompile the project, and re-transfer to the panel.
Frequently Asked Questions
Which Siemens HMI panels are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including TP, OP, MP, and Mobile Panel series, as well as PC-based runtime systems. Compatibility depends on the specific panel firmware version.
Which PLCs can communicate with projects created in WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party PLCs can also be connected using OPC or specific communication drivers.
Is WinCC flexible 2008 compatible with TIA Portal?
WinCC flexible 2008 is not natively integrated into TIA Portal. Siemens provides a migration tool to convert WinCC flexible projects to WinCC in TIA Portal, but the two engineering environments are separate.
What Windows operating systems are supported by WinCC flexible 2008?
WinCC flexible 2008 supports Windows XP (SP3), Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 8, Windows 10, or later operating systems.
What is the difference between the WinCC flexible editions (Micro, Compact, Standard, Advanced)?
The editions differ in the number of supported tags, panel types, and available functions. Micro supports basic small panels with limited tags, while Advanced supports up to 100,000 tags, multi-panel projects, and advanced functions such as user administration and scripting.
Troubleshooting
WinCC flexible 2008 fails to install or reports a license error after installation
Check whether the Automation License Manager (ALM) detects a valid license. Verify that the license matches the installed software edition (Micro, Compact, Standard, or Advanced).
Use the Siemens Automation License Manager to install or transfer the correct license. Ensure the license dongle (if used) is properly connected, or activate a software-based license through the ALM.
Project cannot be transferred to the HMI panel
Verify the transfer connection type (USB, Ethernet, or MPI/PROFIBUS). Check that the panel is set to Transfer mode and that the PC firewall or antivirus is not blocking the transfer.
Set the panel to Transfer mode via the Start Center or Control Panel. Disable any firewall rules blocking the WinCC flexible transfer port. Recompile the project before attempting transfer again.
Runtime communication to PLC is lost intermittently
Check the physical communication cable and connector integrity. Verify PLC address configuration in the WinCC flexible project matches the actual PLC settings. Monitor for network load issues on Ethernet connections.
Replace faulty cables or connectors. Correct the PLC address in the project connection settings. For Ethernet connections, check network switch configuration and reduce network load if necessary.
Alarms are not displayed on the HMI panel at runtime
Verify that alarm tags are correctly configured and linked to the appropriate PLC bit addresses. Check that the alarm view or alarm window object is present and visible on the relevant screen.
Review alarm configuration in the WinCC flexible project, confirm PLC tag addresses are correct, and ensure the alarm display object is correctly placed and configured on the HMI screen. Recompile and re-transfer the project.
WinCC flexible engineering software crashes or becomes unresponsive when opening large projects
Check available RAM and disk space on the engineering PC. Large projects with many tags, screens, and graphics can exceed the memory capacity of 32-bit Windows installations.
Increase the RAM on the engineering PC to at least 2 GB, close other running applications, and ensure sufficient free disk space. Consider splitting large projects or migrating to TIA Portal WinCC for better performance on modern hardware.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page