• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6382-2FA08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6382-2FA08-0AV0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6382-2FA08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6382-2FA08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of SIMATIC HMI devices, from Micro Panels to Multi Panels and PC-based systems. The software includes tools for screen design, alarm management, recipe handling, trend displays, and user administration. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. The platform also provides migration tools for converting projects from earlier ProTool and WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and water treatment, where reliable HMI visualization and operator control are required. The software's scalability makes it applicable to both small standalone machines and large distributed production systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Supported HMI Devices SIMATIC Micro Panels, OP/TP Panels, Multi Panels, Mobile Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Operating System Windows XP, Windows Vista, Windows 7
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    User Administration Included
    Migration Support ProTool and earlier WinCC flexible versions
    Certifications CE

    Common Error Codes & System Events

    Error 1
    License not found or invalid license key detected during startup
    Verify that the correct license key is installed using the Automation License Manager. Reinstall or transfer the license if necessary.
    Error 2
    Project compilation error due to incompatible HMI device type selected
    Check that the target HMI device selected in the project matches the actual hardware. Update the device type in project settings and recompile.
    Error 3
    Communication connection to PLC cannot be established
    Verify communication parameters (IP address, MPI address, or PROFIBUS address). Check physical connections and ensure the PLC is in RUN or STOP mode and reachable.
    Error 4
    Transfer to HMI panel failed
    Confirm the HMI panel is in Transfer mode. Check the transfer channel settings (Ethernet, USB, or serial) and ensure firewall settings are not blocking the connection.
    Error 5
    Runtime error on HMI panel after project download
    Check for script errors or missing tag connections in the project. Recompile the project, resolve all reported warnings and errors, and re-download to the panel.
    Error 6
    Automation License Manager reports license in use on another machine
    Use the Automation License Manager to locate and transfer the license from the previous installation. Ensure the license is not simultaneously active on multiple systems.
    Error 7
    Project migration from ProTool or earlier WinCC flexible version fails
    Use the integrated migration wizard and review the migration log for unsupported objects or functions. Manually recreate unsupported elements in WinCC flexible 2008.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI devices including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), Mobile Panels, and PC-based HMI systems running WinCC flexible Runtime.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1200 PLCs?

    Yes, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via Industrial Ethernet using the TCP/IP protocol. Appropriate firmware versions on the S7-1200 are required for full compatibility.

    Can existing ProTool projects be migrated to WinCC flexible 2008?

    Yes, WinCC flexible 2008 includes a migration wizard that converts ProTool projects and earlier WinCC flexible projects to the 2008 format. Some manual adjustments may be required for unsupported functions after migration.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 can be installed on Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not natively supported on Windows 10 or Windows 11 without compatibility measures.

    What is the difference between WinCC flexible Engineering and WinCC flexible Runtime?

    WinCC flexible Engineering (6AV6382-2FA08-0AV0) is the configuration and project development software used on a PC. WinCC flexible Runtime is a separate license that allows a PC to act as an HMI operator station running the visualization project.

    Troubleshooting

    Software fails to start after installation and reports a license error

    Open the Automation License Manager and check whether a valid WinCC flexible 2008 license is present and active on the local machine.

    Transfer or reinstall the correct license using the Automation License Manager. Ensure the license matches the installed software edition (e.g., Standard, Advanced, or Compact).

    Project cannot be transferred to the HMI panel via Ethernet

    Verify the IP address configured in the project transfer settings matches the panel's actual IP address. Check that the panel is set to Transfer mode and that no firewall is blocking port 102 or the transfer port.

    Correct the IP address in the transfer settings, disable any interfering firewall rules, and ensure the HMI panel is in Transfer mode before initiating the download.

    Tags show no values or display '#####' on the HMI panel at runtime

    Check the tag connections in the project for correct PLC address assignments. Verify the communication link between the HMI panel and the PLC is active and error-free.

    Correct any invalid tag addresses in the WinCC flexible project, recompile, and re-download. Confirm the PLC communication connection parameters are correctly configured and the PLC is running.

    WinCC flexible 2008 crashes or freezes during project compilation

    Check available RAM and disk space on the engineering PC. Large projects with many screens or scripts can exhaust system resources on older hardware.

    Close unnecessary background applications to free memory, increase virtual memory if needed, and ensure the PC meets the minimum system requirements for WinCC flexible 2008. Splitting large projects into smaller modules can also help.

    Alarm messages are not displayed on the HMI panel during runtime

    Verify that alarm classes and alarm connections are correctly configured in the WinCC flexible project. Check that the corresponding PLC bit addresses used for alarm triggers are correctly mapped.

    Review the alarm configuration in the project, correct any missing or incorrect tag assignments, recompile the project, and re-download to the HMI panel. Confirm the PLC program is setting the alarm trigger bits as expected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart