• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6382-2EA08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6382-2EA08-0AX0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6382-2EA08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6382-2EA08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing HMI (Human-Machine Interface) applications used with Siemens operator panels and visualization systems. It belongs to the SIMATIC HMI software portfolio and is designed for use on standard PC-based engineering stations.

    WinCC flexible 2008 offers a comprehensive set of engineering tools for creating and managing HMI projects, including tag management, alarm handling, recipe management, and trend displays. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via standard interfaces such as MPI, PROFIBUS DP, and Industrial Ethernet. It features a scalable architecture allowing projects to be migrated from smaller operator panels up to PC-based SCADA systems, and includes tools for multi-language project support and structured project management.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where Siemens SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series are deployed. It is suitable for applications requiring centralized engineering of distributed HMI systems, including automotive production lines, packaging machinery, water treatment facilities, and building automation. The software enables engineers to configure visualization solutions ranging from small standalone panels to networked multi-panel installations.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Engineering Software License
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Compatible HMI Panels SIMATIC TP, OP, MP, Mobile Panel series
    Operating System Windows XP, Windows Vista, Windows 7
    Series/Product Family SIMATIC WinCC flexible
    Project Migration Supports migration from ProTool and earlier WinCC flexible versions
    Language Support Multi-language project configuration
    Certifications CE
    Alarm Management Included
    Recipe Management Included
    Trend Display Included

    Common Error Codes & System Events

    Event ID: 1000001
    Communication error between engineering station and HMI device during download
    Check the physical connection (MPI, PROFIBUS, or Ethernet cable). Verify the correct communication interface and address are configured in the project settings.
    Event ID: 1000002
    License not found or license key invalid
    Verify that the software license dongle (USB or disk-based) is correctly inserted and recognized by the system. Re-run the license manager (SIMATIC Automation License Manager) to check license status.
    Event ID: 1000003
    Project compilation error due to invalid tag configuration
    Open the project in WinCC flexible and review the tag table for missing or incorrectly configured tags. Correct any references to undefined PLC variables and recompile.
    Event ID: 1000004
    Incompatible HMI device type selected for the project
    Verify that the HMI device type configured in the project matches the physical panel being used. Use the 'Change Device Type' function in WinCC flexible if a migration is required.
    Event ID: 1000005
    Runtime error on HMI panel: connection to PLC lost
    Check PLC power and communication cable integrity. Verify PLC address settings match those configured in the WinCC flexible project. Restart both the HMI panel and PLC if necessary.
    Event ID: 1000006
    Insufficient memory on target HMI device for project download
    Reduce project size by removing unused screens, tags, or graphics. Check the memory requirements of the compiled project against the available memory of the target HMI panel.
    Event ID: 1000007
    Version mismatch between engineering software and HMI panel firmware
    Update the HMI panel firmware to a version compatible with WinCC flexible 2008 using the ProSave tool or WinCC flexible transfer function.

    Frequently Asked Questions

    Which SIMATIC HMI panels are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version.

    Which PLC families can communicate with projects created in WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. Third-party PLC communication is also possible via OPC.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted. Some manual rework may be required depending on the complexity of the original project.

    What operating systems are supported by WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP (SP2 or higher), Windows Vista, and Windows 7. It is not natively supported on Windows 10 or later without compatibility measures.

    Is a hardware dongle required to run WinCC flexible 2008?

    Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license may be stored on a USB dongle or transferred to the hard drive depending on the license type purchased.

    Troubleshooting

    Software fails to install or crashes during installation

    Check Windows event logs for installation errors. Verify that the PC meets minimum system requirements and that no conflicting Siemens software versions are installed.

    Uninstall any previous versions of WinCC flexible or conflicting SIMATIC software before reinstalling. Run the installer as Administrator and ensure all Windows updates are applied prior to installation.

    Project cannot be downloaded to the HMI panel

    Verify the communication interface settings in WinCC flexible match the physical connection (MPI address, PROFIBUS address, or IP address). Check that the HMI panel is in transfer mode.

    Set the HMI panel to transfer mode manually via the panel's Start Center or Control Panel. Confirm the correct COM port or network adapter is selected in the WinCC flexible transfer settings and retry the download.

    License error appears when launching WinCC flexible 2008

    Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2008 is listed and active.

    Insert the USB license dongle if not already connected, or use the ALM to transfer the license from another storage location. If the license is corrupted, contact Siemens support for license recovery.

    HMI panel shows 'No connection to PLC' at runtime

    Check the physical communication cable between the HMI panel and PLC. Verify the PLC address and communication parameters configured in the WinCC flexible project match the actual PLC settings.

    Correct any address mismatches in the WinCC flexible project and re-download to the panel. Replace the communication cable if physical damage is suspected, and confirm the PLC is powered and in RUN mode.

    Screens or graphics do not display correctly after project download

    Check whether the project was compiled without errors. Verify that the display resolution and color depth settings in the project match the target HMI panel specifications.

    Adjust the screen resolution and color settings in the WinCC flexible project to match the target panel. Recompile and re-download the project. Clear the panel's memory before downloading if residual data from a previous project is suspected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart