
Siemens 6AV6382-2EA08-0AV0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6382-2EA08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes a library of pre-built faceplates, multilingual project support, and integration with STEP 7 for consistent data management across the automation project.
WinCC flexible 2008 is widely used in manufacturing, process automation, packaging machinery, and building automation applications. It is suitable for projects requiring scalable HMI solutions, from small operator panels such as the TP177 and OP177 series up to multi-panel PC-based SCADA installations. Its compatibility with a broad range of SIMATIC hardware makes it a standard engineering tool in industrial automation environments.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Single-user software license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported Panel Families | SIMATIC HMI TP, OP, MP, Mobile Panel series |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Integration | STEP 7 integration for shared tag database |
| Languages Supported | Multilingual project support (up to 32 languages) |
| Alarm Management | Included (alarm logging, acknowledgement, archiving) |
| Recipe Management | Included |
| Trend Display | Included |
| Scripting | VB Script support for extended functionality |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes & System Events
- Event ID: 1000001
- License not found or invalid license key detected during startup
Verify the license dongle or software license is correctly installed. Use Siemens Automation License Manager (ALM) to check license status and transfer if necessary. - Event ID: 1000002
- Communication error between WinCC flexible runtime and connected PLC
Check physical connection (MPI cable, PROFIBUS, or Ethernet). Verify PLC address settings and communication driver configuration in the project. - Event ID: 1000003
- Tag read/write error — tag value could not be updated from PLC
Check tag address configuration in the project. Confirm the PLC data block or memory address exists and is accessible. Verify PLC is in RUN mode. - Event ID: 1000004
- Archive database error — data logging or alarm archive could not be written
Check available disk space on the target system. Verify write permissions for the archive directory. Reconfigure archive path if necessary. - Event ID: 1000005
- Project transfer error — project could not be downloaded to target panel
Verify network or serial connection to the target panel. Ensure the panel is in transfer mode. Check firewall settings if using Ethernet transfer. - Event ID: 1000006
- Runtime startup failure — WinCC flexible runtime did not start correctly
Check Windows Event Viewer for related system errors. Reinstall WinCC flexible runtime components. Verify that all required Microsoft redistributable packages are installed. - Event ID: 1000007
- Screen object rendering error — graphical element failed to display correctly
Check for corrupted project files. Reopen and recompile the project in the engineering environment. Update graphics drivers on the runtime PC if applicable.
Frequently Asked Questions
Which SIMATIC HMI panels are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of SIMATIC HMI panels including the TP177, OP177, MP277, MP377, Mobile Panel 177, and PC-based systems running WinCC flexible Runtime. Compatibility depends on the specific edition of WinCC flexible installed.
Which operating systems are supported for running WinCC flexible 2008 engineering software?
WinCC flexible 2008 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not natively supported on Windows 10 or Windows 11 without additional compatibility measures.
Can WinCC flexible 2008 communicate with S7-1200 PLCs?
Yes, WinCC flexible 2008 supports communication with SIMATIC S7-1200 PLCs via Industrial Ethernet using the TCP/IP protocol. Appropriate communication drivers must be configured in the project.
Is STEP 7 integration available with WinCC flexible 2008?
Yes, WinCC flexible 2008 integrates with SIMATIC STEP 7, allowing shared use of the symbol table and tag database between the PLC and HMI projects, reducing configuration effort and potential errors.
What is the Automation License Manager and is it required for this software?
The Siemens Automation License Manager (ALM) is a tool used to manage software licenses for SIMATIC products including WinCC flexible. It is required to activate and validate the license for 6AV6382-2EA08-0AV0 before the software can be used.
Troubleshooting
WinCC flexible 2008 fails to start and displays a license error
Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2008 is present and assigned to the local machine.
Transfer a valid license to the engineering PC using the Automation License Manager. If using a USB dongle, ensure it is properly connected and recognized by the system before launching the software.
Project compilation fails with communication driver errors
Review the error log in the WinCC flexible output window. Check whether the correct communication driver for the target PLC (e.g., SIMATIC S7 MPI or Ethernet) is selected in the project connections settings.
Correct the communication driver selection in the project connections. Ensure the PLC type, address, and interface parameters match the physical hardware configuration.
Runtime does not display updated tag values from the PLC
Check the connection status indicator in the WinCC flexible runtime. Verify that the PLC is in RUN mode and that the tag addresses configured in the project match the actual PLC memory layout.
Correct any mismatched tag addresses in the engineering project, recompile, and re-download to the target system. Check physical communication cables and network settings if the connection status shows offline.
Alarm archive fills up and new alarms are no longer recorded
Check the available storage space on the runtime PC or panel. Review the archive configuration in WinCC flexible to determine the maximum archive size and overflow behavior settings.
Free up disk space on the target system or increase the configured archive size. Adjust the archive overflow setting to overwrite oldest entries if continuous logging is required.
Project transfer to HMI panel fails repeatedly
Verify that the panel is set to transfer mode (accessible via the panel's Start Center or Control Panel). Check the transfer connection type (USB, Ethernet, or serial) and confirm the correct interface is selected in WinCC flexible.
Restart the panel in transfer mode and retry the download. If using Ethernet, ensure both devices are on the same subnet and that Windows Firewall is not blocking the WinCC flexible transfer port.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page



