
Siemens 6AV6382-2HA08-0AV0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6382-2HA08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.
WinCC flexible 2008 offers a scalable engineering environment supporting a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based systems. The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. It includes features such as faceplates, scripts, alarm management, trend displays, recipe management, and multi-language project support. The platform supports project migration from earlier WinCC flexible versions and ProTool projects.
WinCC flexible 2008 is widely used in manufacturing automation, process control, and machine building industries where Siemens SIMATIC HMI panels are deployed. It is suitable for applications in automotive production lines, food and beverage processing, packaging machinery, and water treatment facilities. The software's scalability makes it applicable for both small standalone machine HMIs and larger distributed visualization systems.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Software Type | Engineering Software / HMI Configuration Tool |
| License Type | Single-user license |
| Compatible HMI Hardware | SIMATIC HMI Micro Panels, Mobile Panels, Operator Panels, Multi Panels, Panel PCs |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS, PROFINET, Ethernet |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Project Migration | ProTool, WinCC flexible 2004/2005/2007 |
| Languages Supported | Multi-language project support |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000001
- Communication error between engineering station and HMI panel during project download
Check the communication cable and interface settings. Verify the correct communication driver is selected and the PLC/panel address is correctly configured in the project. - Event ID: 1000002
- License not found or license key invalid
Verify the software license dongle (USB or disk-based) is correctly inserted. Use the Automation License Manager to check license status and re-activate if necessary. - Event ID: 1000003
- Project compilation error due to inconsistent tag configuration
Open the project in WinCC flexible and review the tag table for duplicate names, invalid data types, or missing PLC connections. Recompile after corrections. - Event ID: 1000004
- Runtime transfer failed — panel not reachable
Confirm the panel is powered and in transfer mode. Check IP address or PROFIBUS/MPI address settings match between the engineering software and the target panel. - Event ID: 1000005
- Incompatible project version detected on target panel
Verify the WinCC flexible version used to create the project matches the runtime version on the target HMI panel. Upgrade the panel runtime or re-save the project in a compatible version. - Event ID: 1000006
- Alarm log or data log storage full on target device
Clear the alarm log or data log on the HMI panel via the panel's control panel settings. Adjust log size limits in the WinCC flexible project configuration. - Event ID: 1000007
- Script runtime error during project execution
Review VB scripts in the project for syntax errors or invalid object references. Enable script debugging in WinCC flexible and check the diagnostics output for the specific script causing the fault.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (TP/OP 77), Mobile Panels, Operator Panels (TP/OP 170, 177, 270, 277), Multi Panels (MP 270, MP 370, MP 377), and Panel PCs.
Can WinCC flexible 2008 projects be migrated to TIA Portal?
Yes, WinCC flexible 2008 projects can be migrated to TIA Portal using the integrated migration tool available in TIA Portal V13 and later. Some manual rework may be required after migration depending on project complexity.
What operating systems are compatible with WinCC flexible 2008?
WinCC flexible 2008 is compatible with Windows XP (SP2 or higher), Windows Vista, and Windows 7. It is not natively supported on Windows 10 or later without compatibility measures.
Does WinCC flexible 2008 support communication with S7-1200 PLCs?
S7-1200 communication support was introduced in WinCC flexible 2008 SP3 and later service packs. Ensure the correct service pack is installed to enable S7-1200 connectivity.
Is a hardware dongle required to run WinCC flexible 2008?
Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager. The license may be stored on a USB dongle or transferred to the hard drive depending on the license type.
Troubleshooting
Project download to HMI panel fails with communication error
Check whether the panel is in transfer mode and verify the communication interface settings (MPI address, PROFIBUS address, or IP address) in both the panel's control panel and the WinCC flexible project settings.
Set the panel to transfer mode manually via the panel's Start Center. Ensure the PC interface (e.g., PC Adapter USB) is correctly configured in the Set PG/PC Interface dialog. Match all address parameters between the project and the panel.
WinCC flexible 2008 software does not start after installation
Check the Automation License Manager to confirm a valid license is present. Verify that the installation completed without errors and that the operating system meets the minimum requirements.
Re-activate the license using the Automation License Manager. If the license is missing, re-insert the USB dongle or restore the license from backup. Repair the installation via the Windows Control Panel if necessary.
Compilation errors appear when building the HMI project
Review the output window in WinCC flexible for specific error messages. Common causes include duplicate tag names, invalid PLC connections, or unsupported functions for the selected target panel type.
Correct all flagged errors in the tag table, screen objects, and connection settings. Ensure the target panel type selected in the project matches the actual hardware being used.
Runtime on the HMI panel shows 'No connection to PLC' message
Verify the PLC is powered and running. Check the communication cable between the panel and PLC, and confirm the PLC address configured in the WinCC flexible project matches the actual PLC address.
Replace or reseat the communication cable. Correct the PLC address in the WinCC flexible connection settings and re-download the project to the panel. Check the PLC program is in RUN mode.
Alarm log fills up rapidly causing panel performance degradation
Check the alarm configuration in the WinCC flexible project for alarms that are triggering at high frequency due to signal noise or incorrect limit values.
Review and adjust alarm trigger conditions and hysteresis settings in the project. Increase the alarm log buffer size or reduce the number of logged alarms. Clear the existing log on the panel via the panel control panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page



