• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CB07-5AV3 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CB07-5AV3 WinCC flexible 2007

    € 489,00

    Reset
    Clear
    SKU: 6AV6381-2CB07-5AV3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CB07-5AV3 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure and program Siemens HMI panels, including the TP, OP, MP, and Mobile Panel series. It is designed for use on standard engineering PCs running compatible Windows operating systems.

    WinCC flexible 2007 Compact offers a project-oriented engineering workflow with a structured tag management system, alarm logging, recipe management, and trend display configuration. The software supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via standard interfaces such as MPI, PROFIBUS, and Ethernet. It includes a simulation function that allows offline testing of HMI projects without connected hardware, and supports multi-language project configuration for international deployments.

    This software is primarily used in machine-level automation projects across manufacturing, packaging, food and beverage, and process industries. It is suited for small to medium-scale HMI applications where a compact engineering tool is required to configure operator panels for local machine control and visualization. The Compact edition is targeted at applications that do not require the full-scale capabilities of the Standard or Advanced WinCC flexible editions.

    Technical Specifications

    Software Edition WinCC flexible 2007 Compact
    License Type Single-user license
    Compatible HMI Devices Siemens TP, OP, MP, and Mobile Panel series
    PLC Compatibility S7-200, S7-300, S7-400
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet
    Simulation Function Integrated offline simulation
    Multi-language Support Yes
    Recipe Management Yes
    Alarm Logging Yes
    Trend Display Configuration Yes
    Compatible Operating Systems Windows XP (SP2 or higher), Windows Vista, Windows 7
    Series/Product Family WinCC flexible 2007

    Common Error Codes and System Events

    Error 1920
    Software license not found or invalid license key detected during startup.
    Verify the license key is correctly installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Error 1722
    Installation error during WinCC flexible setup, typically related to a Windows Installer package failure.
    Ensure the installation is run with administrator privileges. Check Windows Installer service is running and retry installation.
    Communication Error
    No connection established between the engineering PC and the target HMI device during project download.
    Check the physical cable connection and verify the correct communication interface (MPI, PROFIBUS, or Ethernet) is selected in the project settings. Confirm PC adapter drivers are installed.
    Compilation Error
    Project compilation fails due to inconsistent tag references or missing screen objects.
    Review the compiler output log, resolve all referenced tag errors, and ensure all linked screens and objects are correctly configured before recompiling.
    Simulation Fault
    Offline simulation terminates unexpectedly or fails to launch.
    Ensure all required WinCC flexible runtime components are installed. Check for conflicting software or insufficient system resources on the engineering PC.
    Transfer Error
    Project transfer to HMI panel fails or is interrupted.
    Verify the HMI panel is in transfer mode, check the communication settings match between the engineering software and the panel, and confirm the correct COM port or network address is configured.
    Version Mismatch
    Project file was created with a different version of WinCC flexible and cannot be opened or migrated.
    Use the WinCC flexible migration tool to convert the project to the current version, or install the matching software version that corresponds to the project file.

    Frequently Asked Questions

    Which HMI panels are supported by WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact supports Siemens TP, OP, MP, and Mobile Panel series HMI devices. It does not support the full range of panels available in the Standard or Advanced editions.

    Which PLCs can communicate with HMI projects configured in this software?

    Projects configured with WinCC flexible 2007 Compact can communicate with Siemens S7-200, S7-300, and S7-400 PLCs using MPI, PROFIBUS DP, or Industrial Ethernet interfaces.

    Does WinCC flexible 2007 Compact support Windows 10?

    WinCC flexible 2007 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues may occur on newer operating systems.

    Is an offline simulation function included in this edition?

    Yes, WinCC flexible 2007 Compact includes an integrated offline simulation function that allows HMI projects to be tested on the engineering PC without a connected HMI panel.

    What is the difference between WinCC flexible Compact, Standard, and Advanced editions?

    The Compact edition supports a limited set of HMI devices and basic functionality. The Standard edition adds support for more panel types and additional features, while the Advanced edition provides the full range of HMI devices, server functionality, and advanced scripting capabilities.

    Troubleshooting

    Software fails to start after installation and reports a license error

    Check the Siemens Automation License Manager (ALM) to verify whether a valid license is present and correctly assigned to the local machine.

    Reinstall the license using the ALM tool. If the license was previously on a different machine, transfer it back using the ALM license transfer function. Ensure the license matches the installed edition (Compact).

    Project download to HMI panel fails with a communication error

    Verify the physical connection between the PC and the HMI panel. Check that the correct interface (MPI, PROFIBUS, or Ethernet) is selected in the project transfer settings and that the PC adapter is recognized by Windows.

    Install or reinstall the PC adapter drivers (e.g., PC Adapter USB), set the correct baud rate and bus address in the transfer settings, and ensure the HMI panel is set to transfer mode before initiating the download.

    WinCC flexible 2007 cannot be installed on the engineering PC

    Check the Windows version and service pack level. Confirm that the installation is being run with local administrator rights and that no previous partial installation is present.

    Uninstall any remnants of previous installations using the Windows Programs and Features tool, ensure the PC meets the minimum system requirements, and run the installer as administrator. Apply any required Windows updates before retrying.

    Compiled project generates multiple tag or screen reference errors

    Open the compiler output window and review each listed error. Identify tags that are referenced in screens or alarms but are not defined in the tag table.

    Add missing tags to the tag table with the correct data type and PLC address, remove or correct broken object references in screens, and recompile the project until no errors remain.

    Offline simulation crashes or displays incorrect screen behavior

    Check whether all required WinCC flexible runtime simulation components were installed during setup. Verify that the PC has sufficient RAM and that no other resource-intensive applications are running simultaneously.

    Perform a repair installation of WinCC flexible 2007 to restore any missing simulation components. Close unnecessary background applications and retry the simulation with a simplified project to isolate the cause.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart