Siemens 6AV6381-2CB07-5AV3 WinCC flexible 2007
€ 489,00
The Siemens 6AV6381-2CB07-5AV3 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure and program Siemens HMI panels, including the TP, OP, MP, and Mobile Panel series. It is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2007 Compact offers a project-oriented engineering workflow with a structured tag management system, alarm logging, recipe management, and trend display configuration. The software supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via standard interfaces such as MPI, PROFIBUS, and Ethernet. It includes a simulation function that allows offline testing of HMI projects without connected hardware, and supports multi-language project configuration for international deployments.
This software is primarily used in machine-level automation projects across manufacturing, packaging, food and beverage, and process industries. It is suited for small to medium-scale HMI applications where a compact engineering tool is required to configure operator panels for local machine control and visualization. The Compact edition is targeted at applications that do not require the full-scale capabilities of the Standard or Advanced WinCC flexible editions.
Technical Specifications
| Software Edition | WinCC flexible 2007 Compact |
|---|---|
| License Type | Single-user license |
| Compatible HMI Devices | Siemens TP, OP, MP, and Mobile Panel series |
| PLC Compatibility | S7-200, S7-300, S7-400 |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Industrial Ethernet |
| Simulation Function | Integrated offline simulation |
| Multi-language Support | Yes |
| Recipe Management | Yes |
| Alarm Logging | Yes |
| Trend Display Configuration | Yes |
| Compatible Operating Systems | Windows XP (SP2 or higher), Windows Vista, Windows 7 |
| Series/Product Family | WinCC flexible 2007 |
Common Error Codes and System Events
- Error 1920
- Software license not found or invalid license key detected during startup.
Verify the license key is correctly installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary. - Error 1722
- Installation error during WinCC flexible setup, typically related to a Windows Installer package failure.
Ensure the installation is run with administrator privileges. Check Windows Installer service is running and retry installation. - Communication Error
- No connection established between the engineering PC and the target HMI device during project download.
Check the physical cable connection and verify the correct communication interface (MPI, PROFIBUS, or Ethernet) is selected in the project settings. Confirm PC adapter drivers are installed. - Compilation Error
- Project compilation fails due to inconsistent tag references or missing screen objects.
Review the compiler output log, resolve all referenced tag errors, and ensure all linked screens and objects are correctly configured before recompiling. - Simulation Fault
- Offline simulation terminates unexpectedly or fails to launch.
Ensure all required WinCC flexible runtime components are installed. Check for conflicting software or insufficient system resources on the engineering PC. - Transfer Error
- Project transfer to HMI panel fails or is interrupted.
Verify the HMI panel is in transfer mode, check the communication settings match between the engineering software and the panel, and confirm the correct COM port or network address is configured. - Version Mismatch
- Project file was created with a different version of WinCC flexible and cannot be opened or migrated.
Use the WinCC flexible migration tool to convert the project to the current version, or install the matching software version that corresponds to the project file.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2007 Compact?
WinCC flexible 2007 Compact supports Siemens TP, OP, MP, and Mobile Panel series HMI devices. It does not support the full range of panels available in the Standard or Advanced editions.
Which PLCs can communicate with HMI projects configured in this software?
Projects configured with WinCC flexible 2007 Compact can communicate with Siemens S7-200, S7-300, and S7-400 PLCs using MPI, PROFIBUS DP, or Industrial Ethernet interfaces.
Does WinCC flexible 2007 Compact support Windows 10?
WinCC flexible 2007 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues may occur on newer operating systems.
Is an offline simulation function included in this edition?
Yes, WinCC flexible 2007 Compact includes an integrated offline simulation function that allows HMI projects to be tested on the engineering PC without a connected HMI panel.
What is the difference between WinCC flexible Compact, Standard, and Advanced editions?
The Compact edition supports a limited set of HMI devices and basic functionality. The Standard edition adds support for more panel types and additional features, while the Advanced edition provides the full range of HMI devices, server functionality, and advanced scripting capabilities.
Troubleshooting
Software fails to start after installation and reports a license error
Check the Siemens Automation License Manager (ALM) to verify whether a valid license is present and correctly assigned to the local machine.
Reinstall the license using the ALM tool. If the license was previously on a different machine, transfer it back using the ALM license transfer function. Ensure the license matches the installed edition (Compact).
Project download to HMI panel fails with a communication error
Verify the physical connection between the PC and the HMI panel. Check that the correct interface (MPI, PROFIBUS, or Ethernet) is selected in the project transfer settings and that the PC adapter is recognized by Windows.
Install or reinstall the PC adapter drivers (e.g., PC Adapter USB), set the correct baud rate and bus address in the transfer settings, and ensure the HMI panel is set to transfer mode before initiating the download.
WinCC flexible 2007 cannot be installed on the engineering PC
Check the Windows version and service pack level. Confirm that the installation is being run with local administrator rights and that no previous partial installation is present.
Uninstall any remnants of previous installations using the Windows Programs and Features tool, ensure the PC meets the minimum system requirements, and run the installer as administrator. Apply any required Windows updates before retrying.
Compiled project generates multiple tag or screen reference errors
Open the compiler output window and review each listed error. Identify tags that are referenced in screens or alarms but are not defined in the tag table.
Add missing tags to the tag table with the correct data type and PLC address, remove or correct broken object references in screens, and recompile the project until no errors remain.
Offline simulation crashes or displays incorrect screen behavior
Check whether all required WinCC flexible runtime simulation components were installed during setup. Verify that the PC has sufficient RAM and that no other resource-intensive applications are running simultaneously.
Perform a repair installation of WinCC flexible 2007 to restore any missing simulation components. Close unnecessary background applications and retry the simulation with a simplified project to isolate the cause.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page