• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CB07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CB07-5AV0 WinCC flexible 2007

    € 1.667,00

    Reset
    Clear
    SKU: 6AV6381-2CB07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CB07-5AV0 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure and program Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is designed for use on a standard engineering PC running a compatible Windows operating system.

    WinCC flexible 2007 Compact supports project creation for smaller HMI devices and includes tools for screen design, tag management, alarm configuration, recipe handling, and report generation. The software communicates with Siemens SIMATIC PLCs via integrated drivers and supports MPI, PROFIBUS DP, and PROFINET/Ethernet connections. It is compatible with the SIMATIC Manager and TIA Portal environment for integrated project workflows, and includes a runtime simulator for offline testing of HMI projects.

    This software is used across a wide range of industrial automation applications where Siemens HMI panels are deployed, including machine tools, packaging machinery, conveyor systems, and process automation equipment. The Compact edition is suited for smaller installations and entry-level HMI configurations, making it a practical choice for OEMs and system integrators working with Siemens panel hardware in manufacturing and production environments.

    Technical Specifications

    Software Version WinCC flexible 2007 Compact
    License Type Single-user license
    Compatible HMI Devices SIMATIC HMI OP, TP, MP, Mobile Panel series
    Supported PLC Communication MPI, PROFIBUS DP, PROFINET, Ethernet
    Operating System Windows XP, Windows Vista (32-bit)
    Runtime Simulator Included
    Tag Limit Up to 128 tags (Compact edition)
    Alarm Configuration Supported
    Recipe Management Supported
    Report Generation Supported
    Integration SIMATIC Manager compatible
    Series/Product Family WinCC flexible

    Common Error Codes and Software Events

    Error 1920
    Software license not found or license key invalid during installation or startup.
    Verify the license key supplied with the package. Use the Siemens Automation License Manager (ALM) to check license status and transfer or repair the license as needed.
    Error 1935
    Assembly component installation failure during WinCC flexible setup.
    Ensure all prerequisite software including .NET Framework and Visual C++ redistributables are installed. Run the installer as Administrator and disable antivirus software during installation.
    Runtime Simulator Error
    Runtime simulator fails to start or crashes during project simulation.
    Check that the PC meets minimum hardware requirements. Reinstall the WinCC flexible runtime simulator component via the installation media's repair function.
    Communication Error
    No communication established between the engineering PC and the HMI panel during project download.
    Verify the correct communication driver is selected in the project settings. Check physical cable connections and confirm the PC network adapter or MPI/PROFIBUS adapter is properly configured.
    Compiler Error
    Project compilation fails with syntax or configuration errors.
    Review the error log in the output window for specific tag or screen references. Correct invalid tag addresses, missing connections, or unsupported object configurations for the target HMI device.
    License Transfer Error
    License cannot be transferred to a new PC using the Automation License Manager.
    Ensure the ALM version is compatible with WinCC flexible 2007. Use a USB dongle or perform an online transfer if available. Contact Siemens support if the license shows as defective.
    Device Type Mismatch
    Project cannot be downloaded because the configured HMI device type does not match the connected hardware.
    Open the project properties and verify the target device type and firmware version match the physical HMI panel. Update the device type setting and recompile before downloading.

    Frequently Asked Questions

    What HMI panels are supported by WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact supports configuration of smaller Siemens SIMATIC HMI panels including selected OP, TP, and Mobile Panel devices. The Compact edition has limitations on the number of tags and screens compared to the Standard or Advanced editions.

    What is the maximum number of tags supported in the Compact edition?

    The Compact edition of WinCC flexible 2007 supports up to 128 configurable tags per project, which is suitable for smaller HMI applications.

    Is WinCC flexible 2007 compatible with TIA Portal?

    WinCC flexible 2007 is not natively part of the TIA Portal environment; it is a standalone engineering tool. However, projects can be migrated to WinCC in TIA Portal using Siemens migration tools.

    What communication interfaces are supported for downloading projects to HMI panels?

    Projects can be downloaded via MPI, PROFIBUS DP, Ethernet, or USB depending on the target HMI panel's available interfaces and the PC adapter used.

    Can WinCC flexible 2007 run on Windows 10?

    WinCC flexible 2007 was designed for Windows XP and Windows Vista. It is not officially supported on Windows 10, and compatibility issues are likely without virtualization or a legacy PC environment.

    Troubleshooting

    Software fails to install on the engineering PC

    Check Windows event logs and the installer log file for specific error codes. Verify that the operating system version is compatible and that all prerequisites such as .NET Framework are present.

    Install all required prerequisites listed in the WinCC flexible 2007 readme file. Run the installer with Administrator privileges and temporarily disable antivirus and firewall software during installation.

    License not recognized after installation

    Open the Siemens Automation License Manager and check whether the WinCC flexible 2007 Compact license is listed and shows a valid status.

    If the license is missing or shows as defective, use the ALM to repair or re-transfer the license from the original storage medium. Ensure the correct license type matches the installed software edition.

    Project download to HMI panel fails

    Verify the communication settings in the project transfer dialog. Check that the correct interface, baud rate, and device address are configured and that the physical connection cable is functional.

    Replace or test the communication cable. Confirm the HMI panel is in transfer mode. Ensure the PC adapter driver (e.g., PC Adapter USB for MPI/PROFIBUS) is correctly installed and recognized by Windows.

    Compiled project generates unexpected alarms or missing tags at runtime

    Review the tag configuration in the engineering software for incorrect PLC addresses or data type mismatches. Check that the PLC program tag addresses correspond exactly to those configured in WinCC flexible.

    Correct any mismatched tag addresses or data types in the WinCC flexible tag editor. Recompile the project and re-download to the HMI panel after verifying the PLC program is running correctly.

    Runtime simulator crashes or does not reflect project changes

    Check whether the project was fully compiled without errors before launching the simulator. Verify available RAM and CPU resources on the engineering PC.

    Perform a full project compilation, then restart the simulator. If the issue persists, repair the WinCC flexible installation using the original installation media and ensure no conflicting software is running.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart