• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CB07-5AK4 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2CB07-5AK4 WinCC flexible 2007

    € 321,00

    Reset
    Clear
    SKU: 6AV6381-2CB07-5AK4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CB07-5AK4 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure, program, and commission Siemens HMI panels, including the OP, TP, MP, and Mobile Panel series. It is designed for use on standard engineering PCs running compatible Windows operating systems.

    WinCC flexible 2007 Compact supports project creation for a defined range of smaller HMI devices and includes tools for screen design, tag management, alarm configuration, recipe handling, and communication setup. The software integrates with the SIMATIC Manager and supports communication with S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It provides a structured project environment with library functions, object-based screen editing, and simulation capabilities for offline testing of HMI projects.

    This software is primarily used in machine-level automation applications where a dedicated engineering tool is required to develop HMI visualization projects for panel-based operator interfaces. Typical industries include manufacturing, packaging, food and beverage, and general machine building. It is suited for system integrators and OEMs who develop standardized HMI solutions based on the Siemens SIMATIC HMI platform.

    Technical Specifications

    Software Version WinCC flexible 2007 Compact
    License Type Single-user license
    Compatible HMI Devices SIMATIC HMI OP, TP, MP, and Mobile Panel series (Compact-class devices)
    PLC Compatibility S7-200, S7-300, S7-400
    Communication Interfaces Supported MPI, PROFIBUS DP, Industrial Ethernet
    Operating System Windows XP (SP2 or higher), Windows 2000 Professional
    Integration SIMATIC Manager (STEP 7)
    Simulation Offline project simulation supported
    Series/Product Family WinCC flexible
    Language Support Multilingual project engineering supported
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000001
    License not found or invalid license key detected during software startup
    Verify that the correct license key is installed using the Automation License Manager. Reinstall or transfer the license if necessary.
    Event ID: 1000002
    Project version mismatch — project was created with a newer or incompatible version of WinCC flexible
    Open the project with the correct version of WinCC flexible or use the migration wizard to convert the project to the installed version.
    Event ID: 1000010
    Communication error between engineering PC and HMI panel during project download
    Check the physical connection (MPI cable, PROFIBUS, or Ethernet). Verify interface settings in the PC System Properties and confirm the correct transfer channel is selected in WinCC flexible.
    Event ID: 1000020
    Compilation error — project contains invalid tag references or missing screen objects
    Run the project compiler and review the error log. Correct all invalid tag assignments and ensure all referenced screens and objects exist within the project.
    Event ID: 1000030
    Simulation startup failure — runtime simulation could not be initialized
    Ensure the WinCC flexible Runtime simulation component is installed. Check that no other runtime instance is already active and that the PC meets minimum system requirements.
    Event ID: 1000040
    Device type not supported — selected HMI target device is not supported by the installed software edition
    Verify that the target HMI device is within the scope of the Compact edition. Upgrade to WinCC flexible Standard or Advanced if a higher-class device is required.

    Frequently Asked Questions

    Which HMI devices can be configured with WinCC flexible 2007 Compact?

    WinCC flexible 2007 Compact supports configuration of smaller SIMATIC HMI devices including Micro Panels, OP 73, TP 177 Micro, and other Compact-class panels. Higher-class panels such as the MP 277 or MP 377 require the Standard or Advanced edition.

    Is WinCC flexible 2007 compatible with TIA Portal projects?

    No, WinCC flexible 2007 is not directly compatible with TIA Portal. Projects created in WinCC flexible can be migrated to TIA Portal using the migration tool included in TIA Portal, but the process requires manual review and adjustment.

    Which PLCs can communicate with HMI panels configured using this software?

    WinCC flexible 2007 supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet, as well as a range of third-party controllers through configurable drivers.

    Can this software license be transferred to another PC?

    Yes, the license can be transferred between PCs using the Siemens Automation License Manager (ALM). The license must be properly deactivated on the source machine before activation on the target machine.

    Does WinCC flexible 2007 Compact support alarm and recipe management?

    Yes, the Compact edition includes basic alarm logging and recipe management functionality, though the number of alarms, recipes, and tags may be limited compared to the Standard and Advanced editions.

    Troubleshooting

    Software fails to start and displays a license error

    Open the Siemens Automation License Manager and check whether a valid WinCC flexible 2007 Compact license is present and active on the current PC.

    Transfer or reinstall the correct license using the Automation License Manager. Ensure the license matches the installed software edition (Compact, Standard, or Advanced).

    Project download to HMI panel fails with a communication error

    Check the physical cable connection between the engineering PC and the HMI panel. Verify the selected transfer channel in WinCC flexible matches the actual interface being used (MPI, PROFIBUS, or Ethernet).

    Correct the interface settings in the PC System Properties under SIMATIC NET. Use the correct cable type (e.g., PC-MPI adapter or standard Ethernet cable) and confirm the HMI panel is in transfer mode.

    Project compilation produces errors referencing missing tags or screens

    Review the compiler output log to identify which tags or screen references are invalid. Check for deleted or renamed tags that are still referenced in screen objects or alarm configurations.

    Update or remove all invalid tag references in the affected screens and alarm entries. Re-run the compiler to confirm all errors are resolved before attempting a download.

    Simulation does not launch or crashes immediately after starting

    Confirm that the WinCC flexible Runtime simulation module is installed as part of the software installation. Check Windows Event Viewer for application errors related to the simulation process.

    Repair or reinstall the WinCC flexible 2007 software installation, ensuring the simulation component is selected. Verify that the PC meets the minimum RAM and OS requirements for running the simulation.

    Existing project cannot be opened and reports a version incompatibility

    The project was likely created with a newer version of WinCC flexible or a different edition than what is currently installed on the engineering PC.

    Install the correct version of WinCC flexible that matches the project version, or use the WinCC flexible migration wizard available in a newer TIA Portal installation to convert the project format.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart