Siemens 6AV6381-2CA08-0AV0 WinCC flexible 2008
€ 2.032,52
The Siemens 6AV6381-2CA08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment used to develop, commission, and operate HMI (Human-Machine Interface) applications on Siemens SIMATIC HMI panels. It belongs to the SIMATIC WinCC flexible product line, which serves as the predecessor to the current WinCC Comfort/Advanced generation.
WinCC flexible 2008 offers a comprehensive engineering environment for creating HMI visualization projects compatible with a wide range of Siemens operator panels, including the TP, OP, MP, and Mobile Panel series. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet interfaces. It includes features such as tag management, alarm logging, trend displays, recipe management, and multi-language project support. The 2008 version introduced improved usability, extended panel support, and enhanced integration with the SIMATIC automation environment.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications where Siemens SIMATIC HMI panels are deployed. It is suitable for configuring operator interfaces on packaging machines, conveyor systems, press lines, and general industrial machinery. The software is particularly relevant for maintaining and extending legacy HMI installations that use older Siemens panel hardware not supported by the newer TIA Portal engineering framework.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet |
| Supported Panel Series | SIMATIC TP, OP, MP, Mobile Panel |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Project Languages | Multi-language support |
| Alarm Management | Included |
| Recipe Management | Included |
| Trend Display | Included |
| Integration | SIMATIC STEP 7, SIMATIC NET |
Common Error Codes and System Events
- Event ID: 1000
- Project compilation error — one or more tags or screen objects contain invalid configurations preventing successful compilation.
Review the compiler output log, correct invalid tag references or misconfigured screen objects, and recompile the project. - Event ID: 2001
- Communication connection to PLC lost — the HMI runtime cannot establish or maintain a connection to the configured PLC.
Verify PLC is powered and online, check network or PROFIBUS/MPI cabling, and confirm communication parameters match on both PLC and HMI project. - Event ID: 3010
- Tag limit exceeded — the number of configured tags in the project exceeds the license or panel limit.
Reduce the number of tags used in the project or upgrade to a higher-tier WinCC flexible license that supports more tags. - Event ID: 4005
- Screen object reference error — a screen references an object or template that no longer exists in the project.
Open the affected screen in the engineering tool, identify missing object references, and reassign or recreate the missing objects. - Event ID: 5002
- Runtime license not found — the HMI panel reports that a valid WinCC flexible runtime license is not present.
Transfer a valid runtime license to the target panel using the Automation License Manager tool. - Event ID: 6001
- Transfer connection failed — the engineering PC cannot establish a transfer connection to the target HMI panel.
Check the transfer settings (IP address, transfer mode), ensure the panel is in transfer mode, and verify the network or USB connection between PC and panel. - Event ID: 7003
- Recipe data error — recipe records cannot be read from or written to the panel memory or connected data medium.
Check available storage space on the panel, verify recipe configuration in the project, and ensure the data medium is properly connected and formatted.
Frequently Asked Questions
Which Siemens HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of SIMATIC HMI panels including the TP 177, TP 270, TP 277, MP 277, MP 377, OP 77, OP 177, OP 277, and Mobile Panel 177 series, among others. It does not support the newer Comfort Panel series, which require TIA Portal.
Is WinCC flexible 2008 compatible with TIA Portal projects?
WinCC flexible 2008 projects are not directly compatible with TIA Portal. However, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects for conversion to WinCC Comfort or Advanced format.
What operating systems are supported for running WinCC flexible 2008?
WinCC flexible 2008 is supported on Windows XP (SP3), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later operating systems.
Can WinCC flexible 2008 communicate with S7-1500 PLCs?
WinCC flexible 2008 does not natively support SIMATIC S7-1500 PLCs. Communication with S7-1500 requires TIA Portal with WinCC Comfort or Advanced.
What is the Automation License Manager and is it required?
The Automation License Manager is a Siemens utility used to manage software licenses for products including WinCC flexible. It is required to activate and transfer licenses for both the engineering software and HMI panel runtime licenses.
Troubleshooting
WinCC flexible 2008 fails to install on the engineering PC
Check the Windows version and service pack level. Verify that all prerequisites such as Microsoft .NET Framework and MSXML are installed. Review the installation log for specific error messages.
Ensure the PC runs a supported OS (Windows XP SP3, Vista, or Windows 7). Install all required prerequisites listed in the WinCC flexible 2008 readme file before retrying the installation.
Project cannot be transferred to the HMI panel
Confirm the panel is set to transfer mode. Check the IP address or MPI/PROFIBUS address settings in the transfer dialog match the panel configuration. Verify the physical connection (Ethernet cable or USB) is intact.
Set the panel to transfer mode via its Start Center, correct the transfer settings in WinCC flexible, and retry the transfer. Replace the cable if a physical connection fault is suspected.
Runtime license error displayed on HMI panel after project download
The panel does not have a valid WinCC flexible runtime license installed. Open the Automation License Manager on the engineering PC and check available licenses.
Use the Automation License Manager to transfer a valid WinCC flexible runtime license to the target panel. Ensure the license matches the panel type and required tag count.
Compiled project generates tag communication errors at runtime
Check that the PLC communication driver settings in the WinCC flexible project match the actual PLC configuration, including IP address, rack, slot, and protocol selection.
Correct the communication connection parameters in the WinCC flexible project, recompile, and retransfer the project to the panel. Verify PLC is online and reachable from the panel network.
WinCC flexible 2008 crashes or becomes unstable during project editing
This may be caused by corrupted project files, insufficient system resources, or incompatible software components on the engineering PC.
Repair the WinCC flexible installation via the Windows Control Panel, ensure the PC meets minimum hardware requirements, and restore the project from a recent backup if the project file is corrupted.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page