• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CA08-0AH0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CA08-0AH0 WinCC flexible 2008

    € 1.803,42

    Reset
    Clear
    SKU: 6AV6381-2CA08-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CA08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is designed for use with the full range of Siemens operator panels and touch panels.

    WinCC flexible 2008 offers a comprehensive set of engineering tools for creating HMI projects, including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). It includes a library of pre-built faceplates and symbols, multi-language project support, and integration with the SIMATIC automation framework. The engineering environment runs on standard Windows-based PCs and supports project migration from earlier WinCC flexible versions.

    WinCC flexible 2008 is widely used in manufacturing, process automation, and machine building industries where Siemens SIMATIC HMI panels are deployed. It is suitable for applications ranging from small standalone machines with a single operator panel to distributed systems with multiple HMI stations. Industries such as automotive, food and beverage, packaging, and water treatment commonly use this software to develop and maintain HMI solutions on Siemens hardware.

    Technical Specifications

    Software Version WinCC flexible 2008
    Series/Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, PROFINET/Industrial Ethernet
    Operating System Windows XP, Windows Vista, Windows 7 (32/64-bit)
    Supported HMI Devices SIMATIC HMI Panels, Multi Panels, Mobile Panels, PC-based HMI
    Project Languages Up to 32 languages per project
    Tag Limit Dependent on license edition (Compact, Standard, Advanced)
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported
    Script Support VB Script
    Certifications CE

    Common Error Codes and System Events

    License Error 1
    No valid license found for WinCC flexible 2008 on this PC
    Install the correct license using the Siemens Automation License Manager (ALM). Ensure the license dongle is connected or the software license is properly activated.
    License Error 2
    License has expired or is invalid
    Renew or reactivate the license through the Siemens Automation License Manager. Contact Siemens support if the license key is unrecognized.
    Communication Error
    No connection to the target HMI device during download or online operation
    Check the communication cable and interface settings. Verify the correct communication driver and IP address or MPI address are configured in the project settings.
    Compiler Error
    Project compilation failed due to configuration inconsistencies
    Review the error list in the output window. Correct tag references, screen object properties, or script errors as indicated. Recompile the project.
    Transfer Error
    Project transfer to HMI panel failed
    Ensure the HMI panel is in transfer mode. Verify the communication interface settings match between the engineering PC and the target panel. Check for sufficient memory on the target device.
    Runtime Mismatch
    WinCC flexible Runtime version on the panel does not match the engineering software version
    Update the Runtime software on the HMI panel to the version compatible with WinCC flexible 2008. Use the ProSave tool or transfer the updated runtime via the engineering software.
    Database Error
    Project database is corrupt or cannot be opened
    Use the WinCC flexible project repair function. If unsuccessful, restore the project from a backup. Avoid abrupt shutdowns during project save operations.
    Migration Warning
    Project migrated from an older WinCC flexible version contains unsupported objects or settings
    Review the migration log for unsupported features. Manually reconfigure affected screens, tags, or connections to comply with WinCC flexible 2008 requirements.

    Frequently Asked Questions

    Which PLC families are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and PROFINET/Industrial Ethernet interfaces.

    Which operating systems are supported by WinCC flexible 2008?

    The software supports Windows XP, Windows Vista, and Windows 7 in both 32-bit and 64-bit editions. It is not officially supported on Windows 10 or later without compatibility measures.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, WinCC flexible 2008 projects can be migrated to Siemens TIA Portal using the integrated migration tool. Some manual reconfiguration may be required for unsupported objects after migration.

    What HMI panels are supported by WinCC flexible 2008?

    The software supports the full range of SIMATIC HMI panels including Basic Panels, Comfort Panels (predecessor series), Multi Panels, Mobile Panels, and PC-based HMI systems running WinCC flexible Runtime.

    Is a hardware dongle required to run WinCC flexible 2008?

    Licensing is managed through the Siemens Automation License Manager (ALM). Depending on the license type, a USB dongle or a software-based license may be used.

    Troubleshooting

    WinCC flexible 2008 fails to install on Windows 7 64-bit

    Check system requirements and ensure all prerequisite software components such as .NET Framework and SQL Server are installed. Review the installation log for specific error messages.

    Install all required prerequisites listed in the WinCC flexible 2008 readme file. Run the installer with administrator privileges. Disable antivirus software temporarily during installation if conflicts are detected.

    Project cannot be transferred to the HMI panel

    Verify the communication interface settings in the project match the physical connection (Ethernet, USB, or MPI). Check that the HMI panel is in transfer mode and that no firewall is blocking the connection.

    Set the correct IP address or MPI address in the project transfer settings. Switch the HMI panel to transfer mode via its Start Center. Disable Windows Firewall temporarily to rule out network blocking.

    License not recognized after moving to a new PC

    The license may still be bound to the old PC or storage medium. Open the Automation License Manager to check the license status and location.

    Use the Siemens Automation License Manager to transfer the license from the old PC or USB dongle to the new system. Ensure the ALM version is compatible with WinCC flexible 2008 licenses.

    Compilation errors appear after migrating a project from an older WinCC flexible version

    Review the migration log and the compiler output window for specific unsupported objects, deprecated tags, or missing connections that were not fully converted.

    Manually reconfigure the flagged screens, tags, and communication connections. Replace deprecated objects with their WinCC flexible 2008 equivalents and recompile the project.

    WinCC flexible 2008 crashes or freezes during project editing

    Check available RAM and disk space on the engineering PC. Large projects with many tags or complex scripts can exceed resource limits. Review Windows Event Viewer for application error logs.

    Increase available system memory and ensure at least 10 GB of free disk space. Reduce project complexity where possible. Apply the latest WinCC flexible 2008 service pack and hotfixes available from Siemens support.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart