
Siemens 6AV6381-2CA08-0AX3 WinCC flexible 2008
€ 490,58
The Siemens 6AV6381-2CA08-0AX3 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes a library of pre-built faceplates and graphic objects, supports multi-language project configuration, and is compatible with Windows XP and Windows 7 operating systems. The 2008 version introduced enhanced performance, improved usability, and extended device support compared to earlier releases.
WinCC flexible 2008 is widely used in manufacturing, process automation, packaging machinery, and material handling applications where operator visualization and control are required. It is suitable for machine builders and system integrators who need to develop HMI projects for a broad range of SIMATIC operator panels, from the OP 73 and TP 177 series up to the MP 377 multi-panel family. The software is particularly well suited for projects requiring centralized engineering of multiple panel types within a single project environment.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Single-user software license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported Operating Systems | Windows XP (SP2/SP3), Windows Vista, Windows 7 |
| Supported HMI Devices | SIMATIC HMI panels OP 73 to MP 377 series |
| Project Languages | Up to 32 languages per project |
| Engineering Environment | PC-based configuration software |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
Common Error Codes & System Events
- Error 1920
- Runtime license not found or invalid license key detected during startup.
Verify that the correct license key is installed using the Automation License Manager. Transfer or repair the license if necessary. - Error 1921
- License for WinCC flexible Runtime has expired or is a trial license that has timed out.
Install a valid full license via the Automation License Manager. Contact Siemens for license renewal if required. - Communication Error
- Connection to the configured PLC cannot be established during runtime.
Check physical communication cables, verify PLC address settings in the project, and confirm the correct communication driver is installed and configured. - Tag Error
- One or more tags cannot be read from or written to the connected controller.
Verify tag addresses in the project match the PLC data block or memory area. Check PLC program for correct data types and address ranges. - Project Transfer Error
- Project download to the HMI panel fails during transfer via ProSave or the engineering software.
Check the transfer cable or Ethernet connection, ensure the panel is in transfer mode, and verify that the project is compiled without errors before transfer. - Runtime Startup Error
- WinCC flexible Runtime fails to start or crashes immediately after launch on the target panel or PC.
Check available memory on the target device, verify the runtime version matches the project version, and re-transfer the project if the runtime image is corrupted. - Alarm Overflow
- The alarm buffer on the HMI device is full and new alarms cannot be logged.
Acknowledge and clear existing alarms, increase the alarm buffer size in the project settings, or configure alarm archiving to an external storage medium.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports a wide range of SIMATIC HMI panels including the OP 73, TP 177, OP 177, TP 270, OP 270, MP 277, and MP 377 series, as well as PC-based runtime systems.
Is WinCC flexible 2008 compatible with SIMATIC S7-1200 PLCs?
Yes, WinCC flexible 2008 supports communication with S7-1200 PLCs via Ethernet using the S7 protocol, though TIA Portal and WinCC Basic are the preferred tools for newer S7-1200 projects.
What operating systems are supported for running the WinCC flexible 2008 engineering software?
WinCC flexible 2008 supports Windows XP (SP2 and SP3), Windows Vista, and Windows 7 as host operating systems for the engineering environment.
Can multiple HMI panel types be configured within a single WinCC flexible 2008 project?
Yes, WinCC flexible 2008 allows multiple devices of different types to be configured within a single project, enabling centralized engineering and shared tag databases across panel variants.
Is a separate runtime license required in addition to the engineering license?
Yes, a separate WinCC flexible Runtime license is required for each HMI device or PC that will run the visualization project in production. The engineering license covers project creation only.
Troubleshooting
Project cannot be transferred to the HMI panel
Check whether the panel is in transfer mode and verify the communication interface settings (USB, Ethernet, or MPI) match those configured in the transfer settings of the engineering software.
Set the panel to transfer mode via the Start Center or loader menu, ensure the correct interface is selected in ProSave or the WinCC flexible transfer dialog, and confirm no firewall is blocking the connection on PC-based transfers.
WinCC flexible 2008 software fails to install or reports a license error after installation
Open the Automation License Manager and check whether a valid license for WinCC flexible 2008 is present and assigned to the local machine.
Transfer the correct license from the license data medium using the Automation License Manager. If the license is missing or corrupted, contact Siemens support for license recovery.
Runtime on the HMI panel shows communication errors and tags display question marks
Verify the PLC is powered and running, check the physical communication cable or network connection, and confirm the PLC address configured in the project matches the actual PLC settings.
Correct the PLC address or communication parameters in the WinCC flexible project, recompile, and re-transfer the project to the panel. Replace the communication cable if a hardware fault is suspected.
Compiled project generates errors or warnings during build in the engineering software
Review the error list in the output window of WinCC flexible 2008. Common causes include invalid tag addresses, missing graphics, or unsupported functions for the selected target device.
Correct all reported errors in the project editor, ensure all referenced tags exist and have valid addresses, and verify that the selected target device type matches the physical panel being used.
HMI panel displays a blank or frozen screen after project startup
Check available RAM and flash memory on the panel, and verify that the runtime version installed on the panel is compatible with the WinCC flexible 2008 project version used during engineering.
Update the panel firmware to a compatible version using ProSave, re-transfer the project, and if the issue persists, perform a factory reset of the panel and reload the project from scratch.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page



