Siemens 6AV6381-2CA07-5AX0 WinCC flexible 2007
€ 1.124,00
The Siemens 6AV6381-2CA07-5AX0 is a software license for WinCC flexible 2007 Compact, part of Siemens' WinCC flexible engineering software family. This product provides the engineering environment used to configure and program Siemens HMI panels, including the OP, TP, and MP series operator panels. It is designed for use on standard engineering PCs running compatible Windows operating systems.
WinCC flexible 2007 Compact supports project creation for a defined range of smaller HMI devices, offering a structured tag management system, alarm logging, recipe management, and screen editor tools. The software integrates with the Siemens SIMATIC environment and supports communication configuration for MPI, PROFIBUS DP, and Ethernet-based connections to SIMATIC S7 PLCs. It includes a simulation function allowing offline testing of HMI projects without physical hardware.
This software is primarily used in machine-level automation projects where Siemens Basic or Compact HMI panels are deployed. Typical industries include packaging machinery, conveyor systems, press and forming equipment, and general factory automation. It is suited for smaller-scale HMI applications where a compact engineering tool with essential visualization and control functionality is required.
Technical Specifications
| Software Version | WinCC flexible 2007 Compact |
|---|---|
| License Type | Single-user license |
| Software Family | WinCC flexible |
| Compatible HMI Devices | SIMATIC HMI Compact and Basic panels (OP, TP, MP series) |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400 |
| Communication Protocols | MPI, PROFIBUS DP, Ethernet (TCP/IP) |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Simulation Function | Integrated offline project simulation |
| Alarm Management | Supported |
| Recipe Management | Supported |
| Tag Management | Structured tag editor included |
| Language Support | Multilingual project engineering supported |
| Integration | SIMATIC Manager / Step 7 integration supported |
Common Error Codes and Software Events
- Error 1920
- Software license not found or license key missing during startup
Verify that the license key (AuthCode) is correctly installed using the Siemens Automation License Manager (ALM). Reinstall the license if necessary. - Error 1603
- Installation failure during WinCC flexible setup
Check that the PC meets minimum system requirements, disable antivirus software during installation, and ensure no conflicting software versions are present. Run the installer as administrator. - Error 2
- Project file cannot be opened — version mismatch
Ensure the project was created with a compatible version of WinCC flexible. Use the migration wizard if upgrading from an older version. - Compiler Error
- Project compilation fails due to invalid tag references or missing connections
Open the project validator, review all reported tag and connection errors, and correct missing or incorrectly configured communication connections. - Simulation Error
- Simulation cannot start — runtime components missing
Reinstall the WinCC flexible runtime simulation component via the original installation media. Ensure all optional components were selected during installation. - License Expired
- Trial or temporary license has expired
Purchase and activate a full license through the Siemens Automation License Manager. Contact Siemens support for license transfer if migrating to a new PC. - Transfer Error
- Project transfer to HMI panel fails
Check the communication cable and interface settings (MPI address, baud rate, or Ethernet IP configuration). Ensure the HMI panel is in transfer mode and the correct communication channel is selected in the project settings.
Frequently Asked Questions
Which HMI panels are supported by WinCC flexible 2007 Compact?
WinCC flexible 2007 Compact supports configuration of Siemens SIMATIC Compact and Basic HMI panels, including selected OP, TP, and MP series devices. It does not support the full range of panels covered by the Standard or Advanced editions.
Is WinCC flexible 2007 compatible with Windows 10?
WinCC flexible 2007 was designed for Windows XP, Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10 and compatibility issues are likely without additional configuration or virtualization.
Can WinCC flexible 2007 projects be migrated to TIA Portal?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, manual adjustments are typically required after migration due to differences in functionality and device support.
Does this license support multiple simultaneous installations?
The 6AV6381-2CA07-5AX0 is a single-user license, permitting installation and use on one engineering PC at a time. Additional licenses are required for use on multiple workstations.
What communication interfaces can be configured with this software?
WinCC flexible 2007 Compact supports configuration of MPI, PROFIBUS DP, and Ethernet (TCP/IP) communication connections between HMI panels and SIMATIC S7 PLCs.
Troubleshooting
Software fails to start after installation with a license error
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 Compact is listed and active.
If no license is found, reinstall the license using the original AuthCode provided with the product. If the license is present but invalid, use ALM to repair or reactivate it.
Project transfer to HMI panel fails with a communication error
Verify the physical connection between the engineering PC and the HMI panel. Check the selected transfer channel (MPI, PROFIBUS, or Ethernet) and confirm the HMI is set to transfer mode.
Correct the communication settings in the project (IP address, MPI address, baud rate) to match the panel configuration. Replace the communication cable if hardware faults are suspected.
Compiled project reports missing tag or connection errors
Run the integrated project validator from the Tools menu to list all configuration errors. Identify tags referencing deleted or renamed connections.
Reassign affected tags to valid connections and re-enter any missing communication parameters. Recompile the project after corrections are made.
WinCC flexible installation fails partway through setup
Review the installation log file generated in the Windows temp directory for specific error codes. Check for conflicting software such as older WinCC versions or incompatible .NET Framework versions.
Uninstall conflicting software, ensure the correct .NET Framework version is installed, and re-run the installer with administrator privileges. Temporarily disable antivirus and firewall software during installation.
Simulation function does not launch or crashes immediately
Check that the simulation runtime component was installed during setup. Verify that no other runtime or simulation process is already running in the background.
Reinstall WinCC flexible 2007 and ensure the simulation component is selected in the custom installation options. Restart the PC and attempt to launch the simulation again.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page