Siemens 6AV6381-2CA07-5AV4 WinCC flexible 2007
€ 213,00
The Siemens 6AV6381-2CA07-5AV4 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is designed for use with the SIMATIC WinCC flexible 2007 platform.
WinCC flexible 2007 offers a comprehensive set of engineering tools for creating HMI visualizations, including tag management, alarm handling, recipe management, and trend displays. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and objects, supports multi-language project configuration, and provides simulation capabilities for offline testing of HMI applications prior to deployment.
WinCC flexible 2007 is used extensively in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, pharmaceuticals, and water treatment. It is suitable for configuring operator panels ranging from small Micro panels to multi-panel systems, making it applicable for both standalone machine HMI solutions and distributed SCADA-level visualization architectures.
Technical Specifications
| Software Version | WinCC flexible 2007 |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Supported Panel Types | Micro Panels, Mobile Panels, Operator Panels, Multi Panels |
| Project Languages | Multi-language support |
| Alarm Management | Included |
| Recipe Management | Included |
| Trend Display | Included |
| Offline Simulation | Included |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
Check that the correct Runtime version is installed on the panel. Verify project compatibility with the Runtime version and re-download the project. - Event ID: 2001
- Communication error — No connection established between HMI and PLC.
Verify network cable connections and check PLC address settings. Confirm that the communication driver and PLC interface parameters match the project configuration. - Event ID: 3010
- Tag read/write error — A configured tag could not be read from or written to the PLC.
Check that the tag address in the HMI project matches the actual PLC data block or memory address. Verify PLC program is running and the address range is accessible. - Event ID: 4000
- Recipe data error — Recipe record could not be read or written correctly.
Check recipe configuration in the engineering software. Verify that the associated PLC tags are correctly mapped and that sufficient memory is available on the panel. - Event ID: 5001
- Alarm logging error — Alarm events could not be written to the alarm log.
Check available storage space on the panel or connected memory card. Verify alarm log configuration and ensure the log file path is correctly defined. - Event ID: 6100
- Project download error — Project transfer to the panel was interrupted or failed.
Check the transfer cable or network connection between the engineering PC and the panel. Ensure the panel is in Transfer mode and that the correct interface is selected in the project transfer settings. - Event ID: 7200
- License error — No valid license found for WinCC flexible engineering software.
Verify that the software license (6AV6381-2CA07-5AV4) is correctly installed and activated. Use the Siemens Automation License Manager to check license status and transfer if necessary.
Frequently Asked Questions
What is included with the 6AV6381-2CA07-5AV4 license?
The 6AV6381-2CA07-5AV4 is a WinCC flexible 2007 engineering software license that includes the full configuration environment for creating and managing HMI projects. It covers tag management, alarm handling, recipe management, trend displays, and offline simulation capabilities.
Which Siemens PLCs are compatible with WinCC flexible 2007?
WinCC flexible 2007 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. Communication is possible via MPI, PROFIBUS DP, and Industrial Ethernet interfaces depending on the PLC and panel hardware used.
Which HMI panels can be configured with this software?
WinCC flexible 2007 supports configuration of the full range of SIMATIC HMI panels, including Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels. The specific features available depend on the panel type selected in the project.
Is WinCC flexible 2007 compatible with Windows 10?
WinCC flexible 2007 was designed for Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues may arise. For Windows 10 environments, Siemens recommends migrating to WinCC (TIA Portal).
How is the license managed and transferred?
The WinCC flexible 2007 license is managed using the Siemens Automation License Manager (ALM). The license can be transferred between PCs using the ALM tool, provided the license key is available on a USB dongle or license disk supplied with the product.
Troubleshooting
WinCC flexible 2007 software fails to install on the engineering PC
Check the Windows operating system version for compatibility. Verify that all prerequisites such as Microsoft .NET Framework and SIMATIC Common Services are installed. Review the installation log for specific error messages.
Ensure the PC is running a supported OS (Windows XP, Vista, or Windows 7). Install all required prerequisites listed in the WinCC flexible 2007 readme file before re-running the installation. Run the installer with administrator privileges.
HMI project cannot be downloaded to the panel
Verify the transfer connection type (USB, Ethernet, or MPI) and confirm the panel is set to Transfer mode. Check that the correct interface is selected in the project transfer settings within WinCC flexible 2007.
Set the panel to Transfer mode via the Start Center or Control Panel on the device. Confirm IP address or MPI address settings match between the engineering software and the panel. Retry the transfer after verifying cable connections.
No communication between HMI panel and PLC after project download
Check the PLC connection parameters in the HMI project, including PLC address, subnet, and communication driver. Verify physical connections on the MPI, PROFIBUS, or Ethernet interface.
Correct any mismatched address or driver settings in the WinCC flexible 2007 project and re-download. Confirm the PLC is in RUN mode and that the network cable or bus connector is properly seated.
License not recognized after installing WinCC flexible 2007
Open the Siemens Automation License Manager and check whether the license for WinCC flexible 2007 is listed and shows a valid status. Check if the license is stored on a USB dongle or was transferred to the hard disk.
Use the Automation License Manager to transfer the license from the installation medium or USB dongle to the local PC. If the license shows as damaged or missing, contact Siemens technical support for license recovery.
Simulation of HMI project fails or crashes during offline testing
Check the project for unresolved tag connections or missing PLC drivers that may cause the simulator to fail. Verify that the PC meets the minimum hardware requirements for running the WinCC flexible Runtime simulator.
Remove or disable external PLC communication connections before running the simulation, as the simulator does not connect to real hardware. Ensure the project has no configuration errors by running the project consistency check in WinCC flexible 2007 before starting the simulation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page