• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BV07-5AH0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BV07-5AH0 WinCC flexible 2007

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6381-2BV07-5AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BV07-5AH0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens SIMATIC panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for industrial automation systems.

    WinCC flexible 2007 offers a comprehensive engineering environment with support for a wide range of SIMATIC HMI devices, including Micro Panels, Mobile Panels, Operator Panels, and Multi Panels. The software supports multiple communication drivers and protocols, including PROFIBUS, PROFINET, MPI, and Ethernet-based connections to SIMATIC S7 PLCs and third-party controllers. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support. The engineering tool runs on standard Windows-based PCs and allows simulation of HMI projects prior to deployment.

    WinCC flexible 2007 is widely used in manufacturing, process automation, automotive production, food and beverage, and packaging industries. It is suitable for applications requiring centralized HMI project management across multiple panel types and machine lines. The software is particularly well-suited for integration with SIMATIC S7-300 and S7-400 PLC families, enabling seamless data exchange and diagnostic visualization in complex automation environments.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Engineering Software License
    Compatible HMI Devices SIMATIC Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based HMI
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, and third-party controllers
    Communication Interfaces PROFIBUS, PROFINET, MPI, Industrial Ethernet
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Project Languages Multi-language support
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Simulation Integrated HMI project simulator
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly.
    Check that the correct runtime version is installed and that the project file is not corrupted. Reinstall the runtime software if necessary.
    Event ID: 1000003
    Communication connection to PLC lost or not established.
    Verify network cabling and communication settings. Check PLC address, subnet configuration, and that the correct communication driver is loaded.
    Event ID: 1000010
    Tag read/write error — a configured tag could not be read from or written to the PLC.
    Verify the tag address in the project configuration matches the actual PLC memory address. Check PLC program and data block availability.
    Event ID: 1000020
    License not found — no valid license for WinCC flexible Runtime detected.
    Check that the software license is correctly installed using the Siemens Automation License Manager (ALM). Transfer or repair the license as required.
    Event ID: 1000030
    Project load error — the runtime project could not be loaded.
    Verify the project file integrity. Recompile and retransfer the project from the engineering station to the HMI device.
    Event ID: 1000040
    Recipe data error — recipe records could not be read or written correctly.
    Check recipe configuration in the project, verify storage media availability, and ensure sufficient memory is available on the HMI device.
    Event ID: 1000050
    Alarm buffer overflow — the alarm buffer has reached its maximum capacity.
    Acknowledge and clear pending alarms. Review alarm configuration to reduce unnecessary alarm generation and increase buffer size if configurable.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports a wide range of SIMATIC HMI devices including Micro Panels (TP 170 Micro), Mobile Panels, Operator Panels (OP 77, OP 177), Multi Panels (MP 277, MP 377), and PC-based HMI systems running WinCC flexible Runtime.

    Is WinCC flexible 2007 compatible with SIMATIC S7-1200 or S7-1500 PLCs?

    WinCC flexible 2007 is primarily designed for use with SIMATIC S7-200, S7-300, and S7-400 PLCs. For S7-1200 and S7-1500 integration, Siemens recommends using TIA Portal with WinCC (TIA Portal) instead.

    What operating systems are supported for running the WinCC flexible 2007 engineering software?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 (32-bit). It is not officially supported on Windows 10 or Windows 11.

    Can WinCC flexible 2007 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects. However, some manual rework may be required depending on the complexity of the project and the target HMI device.

    Does 6AV6381-2BV07-5AH0 include the Runtime license or only the engineering tool?

    The 6AV6381-2BV07-5AH0 part number refers to the WinCC flexible 2007 engineering software package. Runtime licenses for HMI panels are typically included with the panel hardware; separate Runtime PC licenses may need to be ordered independently.

    Troubleshooting

    WinCC flexible Runtime does not start on the HMI panel after project transfer

    Check whether the correct Runtime version is installed on the panel and that the project was compiled without errors in the engineering software. Review the transfer log for any reported issues.

    Ensure the Runtime version on the panel matches the version used in the engineering project. Recompile the project, clear the panel memory, and retransfer the project. Reinstall the Runtime software on the panel if necessary.

    Communication between HMI and PLC is not established

    Verify the communication driver settings in the project, including PLC address, interface type (MPI, PROFIBUS, Ethernet), and baud rate. Check physical cabling and network switch or hub configuration.

    Correct the communication parameters in the WinCC flexible project to match the PLC configuration. Replace or reseat communication cables. Confirm the PLC is in RUN mode and accessible on the network.

    License error displayed when launching WinCC flexible engineering software

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2007 is present and not expired or damaged.

    Transfer a valid license to the engineering PC using the ALM tool. If the license is corrupted, contact Siemens support for license recovery. Ensure the license dongle (if applicable) is properly connected.

    Alarms are not displayed on the HMI panel at runtime

    Check the alarm configuration in the project, including trigger tags, alarm classes, and display settings. Verify that the associated PLC tags are being updated correctly.

    Recheck alarm tag addresses and ensure they correspond to the correct PLC memory locations. Confirm that the alarm view or alarm window object is correctly configured and visible on the active screen.

    Project simulation fails or crashes in the engineering environment

    Check the PC's available RAM and CPU resources during simulation. Verify that no conflicting software or firewall rules are blocking the simulation process.

    Close unnecessary applications to free system resources. Temporarily disable firewall or antivirus software during simulation. Reinstall WinCC flexible 2007 if the issue persists after resource checks.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart