• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BU08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BU08-0AX0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BU08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BU08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying HMI (Human-Machine Interface) applications on Siemens operator panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for a wide range of Siemens HMI hardware targets.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). It includes a library of pre-built faceplates and symbols, multi-language project support, and integration with the Siemens STEP 7 engineering environment. The platform supports both panel-based and PC-based runtime targets, with scalable licensing options depending on the number of process tags required.

    WinCC flexible 2008 is widely used in manufacturing, process automation, water treatment, food and beverage, and machine building industries. It is the standard engineering tool for configuring Siemens SIMATIC HMI panels such as the TP, OP, MP, and Mobile Panel series. The software is particularly suited for applications requiring centralized HMI project management across multiple operator stations and integration with existing SIMATIC automation architectures.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, PROFINET/Industrial Ethernet
    Scripting Support VBScript
    Operating System Windows XP, Windows Vista, Windows 7 (32-bit)
    Integration SIMATIC STEP 7, WinCC (TIA Portal predecessor)
    Supported HMI Targets SIMATIC TP, OP, MP, Mobile Panel series, PC-based runtime
    Languages Supported Multi-language project support
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE
    License Medium Software DVD with electronic license key

    Common Error Codes & System Events

    Event ID: 1000
    Runtime startup failure — WinCC flexible Runtime could not be initialized on the target device.
    Verify that the correct runtime version is installed on the HMI panel and that the project was compiled without errors before transfer.
    Event ID: 2010
    Communication error — Connection to the configured PLC could not be established.
    Check network cabling, verify PLC address settings in the project, and confirm that the PLC is powered and in RUN mode.
    Event ID: 3010
    Tag read/write error — A process tag could not be read from or written to the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts.
    Event ID: 4000
    License not found — No valid license for WinCC flexible engineering or runtime was detected.
    Use the Siemens Automation License Manager (ALM) to verify and activate the license. Ensure the license dongle or software license is correctly installed.
    Event ID: 5020
    Project transfer failed — The project could not be transferred to the target HMI panel.
    Check the transfer connection (USB, Ethernet, or MPI/PROFIBUS). Ensure the HMI panel is in Transfer mode and that the correct communication channel is selected in the transfer settings.
    Event ID: 6001
    Alarm buffer overflow — The alarm log buffer on the HMI device is full.
    Archive or clear existing alarm entries. Increase the alarm buffer size in the project settings if the target device memory allows.
    Event ID: 7005
    Recipe data error — A recipe record could not be read or written correctly.
    Verify recipe configuration in the project, check that the associated PLC tags are accessible, and ensure the recipe data medium (flash/SD card) is not full or corrupted.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series, as well as PC-based runtime targets running Windows.

    Is WinCC flexible 2008 compatible with TIA Portal projects?

    WinCC flexible 2008 is not natively compatible with TIA Portal (which uses WinCC in the TIA environment). However, Siemens provides a migration tool to convert WinCC flexible projects into TIA Portal format.

    What PLC communication protocols does WinCC flexible 2008 support?

    The software supports MPI, PROFIBUS DP, and PROFINET/Industrial Ethernet for communication with SIMATIC S7-series PLCs, as well as OPC for third-party device connectivity.

    What operating systems are supported for the engineering station?

    WinCC flexible 2008 is designed for 32-bit versions of Windows XP, Windows Vista, and Windows 7. It is not officially supported on 64-bit operating systems without compatibility mode.

    How is the license managed for 6AV6381-2BU08-0AX0?

    The license is managed through the Siemens Automation License Manager (ALM). The license key is tied to the installation and must be present (either as a software license or hardware dongle) for the engineering software to operate.

    Troubleshooting

    WinCC flexible 2008 fails to install on the engineering PC

    Check the Windows version and confirm it is a supported 32-bit OS. Review the installation log for missing prerequisites such as .NET Framework or MSXML components.

    Install all required prerequisites listed in the WinCC flexible 2008 readme file, ensure no conflicting software versions are present, and run the installer with administrator privileges.

    Project cannot be transferred to the HMI panel

    Verify the transfer channel settings in WinCC flexible match the physical connection (USB, Ethernet, or MPI). Confirm the HMI panel is set to Transfer mode via its Start Center or loader menu.

    Correct the transfer channel configuration, ensure the panel is in Transfer mode, and check that firewall or antivirus software is not blocking the transfer port on the engineering PC.

    Runtime on HMI panel shows 'No connection to PLC' message

    Check the PLC address and communication parameters configured in the WinCC flexible project. Verify physical cabling between the HMI panel and PLC, and confirm the PLC is powered and in RUN mode.

    Correct the PLC address, subnet mask, and communication interface settings in the project, recompile, and retransfer the project to the HMI panel.

    License error appears when launching WinCC flexible engineering software

    Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is listed and active on the current machine.

    Activate the license using the ALM tool with the provided license key. If the license was previously on another machine, perform a license transfer using the ALM before launching the software.

    Alarms are not displayed on the HMI panel at runtime

    Check the alarm configuration in the WinCC flexible project, including the trigger tags, alarm classes, and display settings. Verify that the alarm view object is correctly placed on the relevant screen.

    Correct the alarm trigger tag addresses to match the PLC program, ensure the alarm view is configured to display the correct alarm classes, recompile the project, and retransfer to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart