• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BV07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BV07-5AV0 WinCC flexible 2007

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6381-2BV07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BV07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for operator panels across the SIMATIC portfolio.

    WinCC flexible 2007 offers a scalable engineering environment supporting a wide range of Siemens HMI hardware, from Micro Panels to Multi Panels and PC-based runtime systems. The software includes libraries of pre-built faceplates, tag management, alarm logging, trend displays, and recipe management. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLC families. The engineering tool runs on Windows-based PCs and allows project transfer via USB, Ethernet, or memory card.

    WinCC flexible 2007 is widely used in manufacturing automation, process control, and machine building applications across industries such as automotive, food and beverage, packaging, and chemical processing. It is particularly suited for projects requiring centralized HMI engineering with deployment across multiple panel types. The software enables consistent visualization standards across a plant or machine line, reducing engineering time when scaling projects from small operator panels to larger multi-panel installations.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Engineering Software License
    Compatible HMI Hardware SIMATIC Micro Panels, OP/TP Panels, Multi Panels, PC Runtime
    Compatible PLCs S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet, USB
    Operating System Windows XP, Windows Vista, Windows 7 (32/64-bit)
    Project Transfer Methods USB, Ethernet, Memory Card, Serial
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Series/Product Family SIMATIC WinCC flexible
    Language Support Multi-language project engineering

    Common Error Codes & System Events

    Event ID: 1000
    Project compilation error — one or more configuration errors detected during project build.
    Review the output window for specific error messages, correct tag references, screen links, or communication settings, then recompile the project.
    Event ID: 1010
    Communication connection to PLC failed — the HMI runtime cannot establish a connection to the configured controller.
    Verify PLC address settings, check physical network or bus connections, confirm PLC is in RUN mode, and ensure correct communication driver is selected.
    Event ID: 1020
    Tag read/write error — a configured tag cannot be read from or written to the PLC.
    Check tag address mapping in the project, confirm the PLC data block or memory area exists, and verify communication is active.
    Event ID: 1030
    License not found — WinCC flexible runtime or engineering license is missing or invalid.
    Insert the valid license key (USB dongle or software license), run the Automation License Manager to verify license status, and reinstall if necessary.
    Event ID: 1040
    Project transfer failed — download of project to HMI panel was unsuccessful.
    Check the transfer cable or network connection, ensure the panel is in transfer mode, verify IP address or bus address settings, and retry the transfer.
    Event ID: 1050
    Alarm buffer overflow — the alarm log has exceeded its configured storage limit.
    Increase the alarm buffer size in project settings, archive older alarm records, or reduce the frequency of alarm events in the application.
    Event ID: 1060
    Recipe data error — recipe records cannot be read or written correctly.
    Check recipe configuration for correct tag assignments and data types, verify available storage on the panel, and re-export/import recipe data if corrupted.
    Event ID: 1070
    Screen navigation error — a configured screen link references a screen that does not exist.
    Review all screen navigation buttons and function keys, correct or remove broken screen references, and recompile and transfer the project.

    Frequently Asked Questions

    Which Siemens PLC families are compatible with WinCC flexible 2007?

    WinCC flexible 2007 supports SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as SIMATIC 505 and third-party controllers via OPC or dedicated drivers.

    What HMI panel types can be configured with this software?

    The software supports the full range of SIMATIC HMI panels including Micro Panels, OP/TP 170, TP/OP 177, MP 277, MP 377, and PC-based WinCC flexible Runtime systems.

    Can projects created in WinCC flexible 2007 be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible projects, though some manual rework may be required for advanced configurations.

    What operating systems are supported for running the engineering software?

    WinCC flexible 2007 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7 in both 32-bit and 64-bit editions.

    Is a hardware dongle required to use this license?

    License activation depends on the license variant; some versions use a USB hardware dongle while others use software-based licensing managed through the Siemens Automation License Manager.

    Troubleshooting

    WinCC flexible 2007 fails to install or crashes during installation

    Check Windows version compatibility and ensure all prerequisites such as Microsoft .NET Framework and Visual C++ redistributables are installed. Review the installation log for specific error codes.

    Install all required Windows updates and prerequisite software components, disable antivirus during installation, and run the installer with administrator privileges. Reinstall if files were corrupted.

    Project cannot be transferred to the HMI panel

    Verify the panel is set to transfer mode (accessible via the panel's Start Center or Control Panel). Check that the IP address or PROFIBUS address in the project matches the panel configuration.

    Set the correct communication parameters in the project transfer dialog, ensure the network cable or USB cable is functional, and confirm no firewall is blocking the transfer port.

    Runtime license error displayed on HMI panel after project download

    The WinCC flexible Runtime license on the panel has expired or is missing. Check license status using the Automation License Manager on the engineering PC.

    Transfer a valid WinCC flexible Runtime license to the panel using the Automation License Manager. Ensure the correct license type matches the panel model and runtime version.

    Tags show no value or display '#####' on the panel at runtime

    This typically indicates a communication failure between the panel and PLC, or an incorrect tag address. Check the connection status indicator in the runtime and verify PLC is online.

    Confirm PLC is running and reachable on the network or bus. Verify tag addresses in the WinCC flexible project match the actual PLC data structure, correct any mismatches, and retransfer the project.

    Alarm list does not update or alarms are not displayed at runtime

    Check that alarm tags are correctly configured and that the PLC bits or words mapped to alarms are being updated. Verify the alarm server is running in the runtime environment.

    Review alarm configuration in the project for correct tag assignments and trigger conditions. Ensure the PLC program is writing to the correct alarm trigger addresses and retransfer the updated project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart