• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BQ07-5AV0 WinCC flexible 2007
    Awaiting product image

    Siemens 6AV6381-2BQ07-5AV0 WinCC flexible 2007

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2BQ07-5AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BQ07-5AV0 is a software license for WinCC flexible 2007, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying human-machine interface (HMI) applications on Siemens panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2007 supports engineering of HMI projects for a wide range of Siemens operator panels, including the OP, TP, MP, and Mobile Panel series. The software provides tools for screen design, alarm management, tag communication, recipe handling, and trend displays. It supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, and integrates with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. The software includes a simulation function allowing project testing without physical hardware.

    WinCC flexible 2007 is used across manufacturing, process automation, and machine building industries where Siemens SIMATIC HMI panels are deployed. It is suitable for applications in automotive production lines, packaging machinery, food and beverage processing, and water treatment facilities. The software is particularly relevant for maintaining and extending legacy HMI installations based on the WinCC flexible platform before migration to TIA Portal-based projects.

    Technical Specifications

    Software Version WinCC flexible 2007
    License Type Single-user software license
    Compatible HMI Panels SIMATIC OP, TP, MP, Mobile Panel series
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet
    Operating System Windows XP, Windows Vista, Windows 7
    Engineering Functions Screen design, alarm management, recipe handling, trend display, tag communication
    Simulation Integrated project simulation without physical hardware
    Series/Product Family SIMATIC WinCC flexible
    Language Support Multi-language project engineering
    Integration Compatible with STEP 7 and SIMATIC Manager

    Common Error Codes and System Events

    Event ID: 1000001
    Communication error between HMI panel and PLC. Connection to the configured controller cannot be established.
    Check physical communication cable and interface settings. Verify PLC address and communication parameters match the project configuration.
    Event ID: 1000002
    Tag read/write error. A configured tag cannot be read from or written to the connected controller.
    Verify the tag address exists in the PLC program. Check data type consistency between HMI tag and PLC variable.
    Event ID: 1000003
    Project download error. Transfer of the HMI project to the target panel failed.
    Check the transfer connection settings. Ensure the panel is in transfer mode and the correct communication interface is selected in the project.
    Event ID: 1000004
    License error. No valid license found for WinCC flexible runtime or engineering software.
    Verify the software license is correctly installed using the Siemens Automation License Manager. Reinstall or transfer the license if necessary.
    Event ID: 1000005
    Alarm buffer overflow. The number of pending alarms exceeds the configured alarm buffer capacity.
    Increase the alarm buffer size in the project settings or acknowledge and clear existing alarms to free buffer space.
    Event ID: 1000006
    Recipe data error. Recipe records cannot be read from or written to the configured storage location.
    Check the recipe storage path and ensure the target storage medium (panel memory or memory card) is accessible and has sufficient free space.
    Event ID: 1000007
    Screen object update error. One or more screen objects cannot be updated due to missing or invalid tag connections.
    Review tag connections for affected screen objects in the engineering software. Ensure all referenced tags are correctly defined and accessible.

    Frequently Asked Questions

    Which Siemens HMI panels are supported by WinCC flexible 2007?

    WinCC flexible 2007 supports the SIMATIC OP, TP, MP, and Mobile Panel series, including panels such as the TP177, OP177, MP277, and MP377. It does not support the newer Comfort Panel series, which requires TIA Portal.

    Is WinCC flexible 2007 compatible with TIA Portal projects?

    WinCC flexible 2007 projects are not directly compatible with TIA Portal. However, Siemens provides a migration tool within TIA Portal to convert WinCC flexible projects for use with newer Comfort Panels.

    What operating systems are supported for running WinCC flexible 2007?

    WinCC flexible 2007 supports Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later operating systems.

    Can WinCC flexible 2007 communicate with S7-1200 PLCs?

    WinCC flexible 2007 can communicate with S7-1200 PLCs via Ethernet using the S7 protocol, though full integration and advanced features are better supported through TIA Portal.

    Does WinCC flexible 2007 include a simulation function?

    Yes, WinCC flexible 2007 includes an integrated simulation function that allows engineers to test and validate HMI projects on a PC without requiring a physical panel or PLC connection.

    Troubleshooting

    HMI panel shows 'No connection to PLC' message at runtime

    Check the communication cable between the panel and PLC. Verify the PLC address, communication interface type, and baud rate settings in the WinCC flexible project match the physical configuration.

    Correct the communication parameters in the project and re-download to the panel. Replace the communication cable if physical damage is found. Ensure the PLC is powered and in RUN mode.

    Project download to panel fails during transfer

    Confirm the panel is set to transfer mode. Check that the PC and panel are connected via the correct interface (USB, Ethernet, or MPI/PROFIBUS) and that the transfer settings in WinCC flexible match the panel configuration.

    Set the panel to transfer mode via the Start Center menu. Verify transfer connection settings in WinCC flexible under Transfer settings. Restart both the panel and the engineering PC if the issue persists.

    Software reports a license error on startup

    Open the Siemens Automation License Manager and check whether a valid license for WinCC flexible 2007 is present and assigned to the local machine.

    If the license is missing, reinstall it from the original license media. If the license is on a USB dongle, ensure the dongle is connected. Transfer the license to the correct machine using the Automation License Manager if it is assigned elsewhere.

    Alarm display on panel does not update or shows stale alarms

    Check the tag connections for the alarm triggers in the project. Verify that the PLC bits associated with alarms are being updated correctly and that the communication connection is active.

    Re-establish the PLC connection if it has dropped. Review and correct alarm tag addresses in the WinCC flexible project. Increase the alarm polling cycle time if the PLC scan cycle is slow.

    Screen objects display '#####' or incorrect values at runtime

    This typically indicates a tag communication error or a mismatch between the tag data type in the HMI project and the actual PLC variable type.

    Verify the data type and address of the affected tags in the WinCC flexible tag table. Correct any mismatches and re-download the project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart