Siemens 6AV6381-2BQ08-0AV0 WinCC flexible 2008
€ 3.495,00
The Siemens 6AV6381-2BQ08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm handling, recipe management, trend displays, and scripting capabilities via VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet (PROFINET). It includes a library of pre-built faceplates and graphical objects, and supports multi-language project configuration for international deployments. The 2008 version introduced enhanced performance, improved usability, and extended device support compared to earlier releases.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for configuring operator panels such as the SIMATIC TP, OP, MP, and Mobile Panel series, enabling operators to monitor and control industrial processes. The software is particularly common in automotive, food and beverage, pharmaceutical, and general manufacturing industries where reliable HMI visualization is required.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| Product Family | SIMATIC WinCC flexible |
| License Type | Engineering Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, PROFINET / Industrial Ethernet |
| Scripting Support | VBScript |
| Supported Panel Series | SIMATIC TP, OP, MP, Mobile Panel |
| Operating System | Windows XP, Windows Vista, Windows 7 (32-bit) |
| Project Languages | Multi-language support |
| Alarm Management | Included |
| Recipe Management | Included |
| Trend Display | Included |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000
- Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device or PC.
Check that the correct runtime version is installed and that the project file is compatible with the runtime version. Reinstall the runtime if necessary. - Event ID: 2010
- Communication error — No connection established between the HMI and the configured PLC.
Verify PLC address settings, check physical communication cable or network connection, and confirm that the PLC is powered and in RUN mode. - Event ID: 3010
- Tag read/write error — A configured tag could not be read from or written to the PLC.
Check tag address configuration in the project, verify PLC data block or memory area exists, and confirm communication link is active. - Event ID: 4000
- Alarm buffer overflow — The alarm buffer on the HMI has reached its maximum capacity.
Acknowledge and clear pending alarms, increase the alarm buffer size in the project configuration, or implement alarm archiving to an external storage medium. - Event ID: 5020
- Recipe data error — A recipe record could not be read or written correctly.
Check recipe configuration and tag assignments in the project. Verify that the target memory area in the PLC is accessible and correctly sized. - Event ID: 6001
- License not found — No valid license for WinCC flexible engineering or runtime was detected.
Install the correct license using the Siemens Automation License Manager (ALM). Ensure the license dongle is connected or the software license is properly activated. - Event ID: 7005
- Project transfer error — Transfer of the compiled project to the HMI panel failed.
Check the transfer connection (USB, Ethernet, or MPI/PROFIBUS), ensure the panel is in transfer mode, and verify that the project is compiled without errors before transferring.
Frequently Asked Questions
Which PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and PROFINET/Industrial Ethernet interfaces.
Which operating systems does WinCC flexible 2008 support for the engineering station?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7 (32-bit). It is not natively supported on Windows 10 or later without compatibility measures.
Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?
Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible projects to be imported and converted, though some manual rework may be required depending on the complexity of the project.
What SIMATIC HMI panels can be configured with this software?
WinCC flexible 2008 supports configuration of the SIMATIC TP, OP, MP, and Mobile Panel series, covering a wide range of panel sizes and performance classes.
Is a license dongle required to use WinCC flexible 2008?
Yes, WinCC flexible 2008 requires a valid license managed through the Siemens Automation License Manager (ALM). The license can be stored on a USB dongle or transferred to the engineering PC's hard drive.
Troubleshooting
WinCC flexible 2008 fails to install on the engineering PC
Check the operating system version and confirm it is a supported 32-bit Windows environment. Review the installation log for specific error messages.
Ensure the PC meets the minimum system requirements, disable antivirus software during installation, and run the installer with administrator privileges. Install any required Microsoft prerequisites such as .NET Framework.
Project transfer to HMI panel fails or times out
Verify the communication interface settings in the transfer dialog match the panel configuration. Check that the panel is set to transfer mode and the physical connection (USB, Ethernet, or serial) is intact.
Restart the HMI panel in transfer mode, confirm IP address or MPI address settings are correct, and retry the transfer. Replace the communication cable if hardware faults are suspected.
Runtime on the HMI panel shows no communication to PLC
Check the connection settings in the project for correct PLC address, communication driver, and interface parameters. Verify the PLC is powered and in RUN mode.
Correct the PLC address and communication parameters in the WinCC flexible project, recompile, and retransfer to the panel. Check physical wiring and network switches if using Ethernet.
License error displayed when launching WinCC flexible engineering software
Open the Siemens Automation License Manager (ALM) and check whether a valid license for WinCC flexible 2008 is present and not expired or moved.
Reinstall or transfer the correct license using ALM. If using a USB dongle, ensure it is properly connected and recognized by the PC. Contact Siemens license support if the license cannot be recovered.
Alarms are not displayed correctly or alarm history is missing
Check the alarm configuration in the project, including trigger tags, alarm classes, and archiving settings. Verify that the alarm buffer size is sufficient for the application.
Increase the alarm buffer size in the project settings, enable alarm archiving to a memory card or external storage, and recompile and retransfer the project to the panel.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page