
Siemens 6AV6381-2BP08-0AX0 WinCC flexible 2008
€ 2.995,00
The Siemens 6AV6381-2BP08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the full runtime and configuration environment for developing HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create, configure, and commission visualization projects across a wide range of Siemens HMI hardware.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces. It includes a library of pre-built faceplates and graphic objects, and supports multi-language project configuration for international deployments. The 2008 edition introduced improved performance, extended panel support, and enhanced integration with STEP 7.
WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and infrastructure applications where SIMATIC HMI panels such as the TP, OP, MP, and Mobile series are deployed. It is particularly suited for machine-level visualization on panels ranging from Micro Panels up to Multi Panels and PC-based runtime systems. Industries including automotive, food and beverage, pharmaceutical, and water treatment rely on this software for operator interface development and process monitoring.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Full software license |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Supported HMI Panels | SIMATIC Micro Panels, TP/OP/MP series, Mobile Panels, PC Runtime |
| Scripting Support | VBScript |
| Alarm Management | Integrated alarm logging and display |
| Recipe Management | Supported |
| Trend Display | Supported |
| Multi-language Support | Yes, multiple project languages configurable |
| STEP 7 Integration | Integrated with SIMATIC STEP 7 |
| Operating System Compatibility | Windows XP, Windows Vista, Windows 7 |
| Series/Product Family | SIMATIC WinCC flexible |
Common Error Codes and System Events
- Event ID: 1000
- Project could not be opened due to version incompatibility between the engineering software and the project file.
Ensure the project was created with WinCC flexible 2008 or earlier. Use the migration wizard to convert projects from older versions if required. - Event ID: 2001
- Communication error between the HMI panel and the PLC. The configured connection cannot be established.
Verify the communication cable and interface settings. Check that the PLC address and network parameters in the project match the physical hardware configuration. - Event ID: 3010
- Tag limit exceeded. The number of configured tags in the project exceeds the licensed tag count for the installed edition.
Reduce the number of tags in the project or upgrade the WinCC flexible license to a higher edition that supports a greater tag count. - Event ID: 4005
- Runtime license not found on the target HMI panel. The panel cannot start the runtime project.
Transfer a valid WinCC flexible Runtime license to the target panel using the Automation License Manager. Ensure the license matches the panel type and runtime version. - Event ID: 5002
- Compilation error during project build. One or more configured objects contain invalid or missing parameters.
Review the compiler output log for specific object references. Correct invalid tag connections, missing graphics, or misconfigured alarm entries before recompiling. - Event ID: 6001
- Transfer to panel failed. The project download was interrupted or the panel could not be reached during transfer.
Check the transfer cable or network connection. Ensure the panel is in Transfer mode and that the correct communication channel is selected in the Transfer Settings dialog. - Event ID: 7003
- Automation License Manager reports that the license key is invalid or has been moved to another system.
Use the Automation License Manager to verify the license status. If the license was moved, recover it from the original storage medium or contact Siemens licensing support.
Frequently Asked Questions
Which SIMATIC HMI panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels (KTP series), Operator Panels (OP series), Touch Panels (TP series), Multi Panels (MP series), and Mobile Panels. PC-based runtime systems are also supported.
Is WinCC flexible 2008 compatible with TIA Portal projects?
No, WinCC flexible 2008 is not directly compatible with TIA Portal. Projects created in WinCC flexible 2008 can be migrated to TIA Portal using the integrated migration tool, but the two engineering environments are separate platforms.
Which PLC communication protocols does WinCC flexible 2008 support?
WinCC flexible 2008 supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) for communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC.
What operating systems are compatible with WinCC flexible 2008 engineering software?
WinCC flexible 2008 is compatible with Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later operating systems.
Does WinCC flexible 2008 require a separate runtime license for each HMI panel?
Yes, each target HMI panel or PC running the WinCC flexible Runtime requires its own runtime license, which is managed through the Siemens Automation License Manager.
Troubleshooting
Software installation fails or aborts partway through on the engineering PC
Check Windows Event Viewer for installation error codes. Verify that the PC meets the minimum system requirements for WinCC flexible 2008 and that no conflicting Siemens software versions are installed.
Uninstall any conflicting or older versions of WinCC flexible or STEP 7 before reinstalling. Run the installer with administrator privileges and ensure the .NET Framework and other prerequisites are installed as specified in the release notes.
Project compilation fails with multiple errors after opening an existing project
The project may have been created with a different version of WinCC flexible or contains references to panel types or tags that are not valid in the current configuration.
Check the compiler log for specific error references. Update panel type settings if the target hardware has changed, and verify all tag connections and graphic object references are valid. Use the consistency check tool before compiling.
Communication between the HMI panel and the S7 PLC is not established at runtime
Verify the physical connection cable and interface type (MPI, PROFIBUS, or Ethernet). Check that the PLC address configured in the WinCC flexible project matches the actual PLC hardware address.
Correct the PLC address and network settings in the project connection configuration. Re-download the project to the panel. If using Ethernet, confirm the IP addresses are on the same subnet and the PLC Ethernet module is active.
License error displayed when launching WinCC flexible engineering software
The Automation License Manager cannot find a valid license on the local PC or connected USB dongle. The license may have been moved or the storage medium is not detected.
Open the Automation License Manager and check the license status. Reconnect the USB license key if applicable, or transfer the license back to the engineering PC from the original storage medium.
Project transfer to HMI panel fails with a connection timeout error
The panel may not be in Transfer mode, or the communication settings in the Transfer dialog do not match the physical connection being used.
Set the HMI panel to Transfer mode manually via the panel's Start Center or Control Panel. Verify the transfer channel settings (USB, Ethernet, or MPI) in WinCC flexible match the connected interface, then retry the transfer.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page



