
Siemens 6AV6381-2BP08-0AV0 WinCC flexible 2008
€ 2.995,00
The Siemens 6AV6381-2BP08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This package is the full runtime and configuration software used to develop, commission, and maintain HMI (Human-Machine Interface) applications for Siemens SIMATIC HMI panels. It belongs to the SIMATIC WinCC flexible product line, which serves as the engineering environment for a wide range of Siemens operator panels and touch displays.
WinCC flexible 2008 provides a comprehensive set of engineering tools for creating HMI visualizations, including tag management, alarm handling, recipe management, trend displays, and scripting via VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Ethernet (TCP/IP) interfaces. It includes a simulation function allowing offline testing of HMI projects without physical hardware, and supports multi-language project development for international deployments. The 2008 SP4 and later releases introduced enhanced compatibility with Windows Vista and Windows 7 operating systems.
WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, water treatment, and process industries. It is the standard engineering tool for configuring Siemens SIMATIC HMI devices such as the TP177, OP177, MP277, MP377, and similar operator panel families. Its scalability makes it suitable for small machine-level HMI applications as well as larger multi-panel SCADA-style installations.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Full software package (engineering + runtime) |
| Supported PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Ethernet (TCP/IP), USB |
| Supported HMI Devices | SIMATIC Micro Panels, OP/TP/MP series operator panels |
| Scripting Support | VBScript |
| Operating System Compatibility | Windows XP, Windows Vista, Windows 7 |
| Project Simulation | Integrated offline simulator included |
| Language Support | Multi-language project development |
| Series/Product Family | SIMATIC WinCC flexible |
| Certifications | CE |
| License Medium | DVD with electronic license key |
Common Error Codes and System Events
- Event ID: 1000
- Application error on startup — WinCC flexible runtime or engineering software fails to launch correctly, often due to missing or corrupted installation files.
Repair or reinstall the WinCC flexible 2008 software installation. Verify that all required Microsoft redistributable packages are installed and that the license key is valid. - Event ID: 1001
- License not found — The software cannot detect a valid license for WinCC flexible 2008 on the local machine or USB dongle.
Check that the SIMATIC Automation License Manager (ALM) is installed and running. Verify the license is correctly transferred to the PC or dongle using the ALM tool. - Communication Error
- Connection to the PLC cannot be established during runtime or simulation, typically caused by incorrect communication settings or missing drivers.
Verify the communication channel settings (IP address, MPI address, PROFIBUS address) in the project. Ensure the correct communication driver is installed and the physical connection is active. - Compiler Error
- Project compilation fails due to invalid tag references, missing screens, or configuration inconsistencies within the HMI project.
Review the output log in the engineering software for specific error references. Correct invalid tag names, missing screen links, or overlapping address assignments before recompiling. - Transfer Error
- Project transfer to the HMI panel fails, often due to a mismatch between the software version and the panel firmware version, or a network/USB connectivity issue.
Ensure the HMI panel firmware is compatible with WinCC flexible 2008. Check the transfer channel settings and confirm the panel is in transfer mode before initiating the download. - Runtime Alarm: Tag Read Error
- During runtime, one or more tags cannot be read from the connected PLC, resulting in substitution values being displayed.
Check PLC program for correct data block and address assignments. Verify the tag address configuration in the WinCC flexible project matches the PLC memory layout. - Simulation Abort
- The integrated simulator terminates unexpectedly, often caused by insufficient system resources or incompatible Windows user account permissions.
Run the simulation as administrator. Ensure the PC meets minimum hardware requirements and close unnecessary background applications to free system resources.
Frequently Asked Questions
Which PLC families are compatible with WinCC flexible 2008?
WinCC flexible 2008 supports SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs, as well as third-party controllers via OPC communication. Communication is possible over MPI, PROFIBUS DP, and Ethernet interfaces.
Which operating systems does WinCC flexible 2008 support?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 8, Windows 10, or Windows 11 without additional compatibility measures.
Can WinCC flexible 2008 projects be migrated to TIA Portal (WinCC Advanced)?
Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, some features and screen objects may require manual rework after migration due to differences between the two platforms.
Is a hardware dongle required to run WinCC flexible 2008?
WinCC flexible 2008 uses the Siemens Automation License Manager (ALM) for license management. The license can be stored on the PC hard drive or on a USB dongle, depending on the license type supplied.
Which Siemens HMI panels can be configured with this software?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including Micro Panels, TP177, OP177, MP277, MP377, and Multi Panels. The specific panel type must be selected during project creation to ensure compatibility.
Troubleshooting
WinCC flexible 2008 fails to install or crashes during installation
Check Windows Event Viewer for installation error codes. Verify that the PC meets minimum system requirements and that no conflicting Siemens software versions are present.
Uninstall any previous WinCC flexible versions using the Siemens Automation Software Uninstaller tool before reinstalling. Ensure Microsoft .NET Framework and Visual C++ redistributables required by the installer are present.
License Manager shows no valid license after installation
Open the Siemens Automation License Manager (ALM) and check whether the license is listed and assigned to the correct target (local drive or USB dongle).
Use the ALM to transfer the license from the installation medium or backup location to the local machine. If the license is missing, contact Siemens support with the license certificate for reactivation.
Project cannot be transferred to the HMI panel
Verify the transfer channel configuration in WinCC flexible (USB, Ethernet, or MPI). Confirm the HMI panel is set to transfer mode and that firewall or antivirus software is not blocking the connection.
Switch the HMI panel to transfer mode manually via the panel's start center. Disable Windows Firewall temporarily during transfer or add WinCC flexible as a firewall exception. Ensure the panel firmware version is compatible with the project version.
Tags show substitution values (dashes or zeros) during runtime simulation
Check the tag address configuration in the project against the PLC data structure. Confirm the communication driver is correctly configured and the simulated PLC connection is active.
Correct any mismatched tag addresses in the tag editor. When using the integrated simulator, use the PLC simulator (S7-PLCSIM) in parallel to provide live tag values during testing.
WinCC flexible engineering software runs slowly or freezes on the PC
Check CPU and RAM usage via Windows Task Manager during operation. Large projects with many tags, screens, or scripts can exceed the resources of older hardware.
Increase available RAM to at least 2 GB (4 GB recommended for large projects). Close background applications and ensure the PC is running a supported and fully updated operating system. Splitting very large projects into smaller modular projects can also improve performance.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page



