• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BJ08-0AH0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BJ08-0AH0 WinCC flexible 2008

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6381-2BJ08-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BJ08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens SIMATIC panels and PC-based systems. It belongs to the broader SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across a wide range of automation tasks.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and objects, supports multi-language project configuration, and provides simulation capabilities for offline testing of HMI projects without physical hardware.

    This software is widely used in manufacturing, process automation, machine building, and plant engineering environments where SIMATIC operator panels such as the TP, OP, MP, and Mobile Panel series are deployed. It is suitable for applications ranging from simple machine control panels to complex multi-panel SCADA-like visualization systems. Industries including automotive, food and beverage, chemical processing, and packaging rely on WinCC flexible 2008 for operator interface development and commissioning.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Engineering Software License
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Scripting Support VBScript
    Supported Panel Series SIMATIC TP, OP, MP, Mobile Panel, Multi Panel
    Operating System Windows XP, Windows Vista, Windows 7
    Project Simulation Integrated offline simulator included
    Language Support Multi-language project configuration
    Alarm Logging Supported
    Recipe Management Supported
    Trend Display Supported
    Certifications CE
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes & System Events

    Event ID: 1000
    Runtime startup error — WinCC flexible Runtime failed to initialize correctly on the target device.
    Check that the correct Runtime version is installed on the panel. Verify project compatibility and re-download the project using the Transfer function.
    Event ID: 2010
    Communication error — No connection established between the HMI panel and the configured PLC.
    Verify PLC address settings, check physical communication cable or network connection, and confirm that the PLC is in RUN mode. Check MPI/PROFIBUS address assignments.
    Event ID: 3000
    Tag read/write error — A configured tag could not be read from or written to the connected controller.
    Check the tag address in the WinCC flexible project against the actual PLC data block or memory address. Ensure the data type matches between HMI tag and PLC variable.
    Event ID: 4010
    Recipe data error — A recipe record could not be read or written correctly.
    Verify recipe configuration in the engineering software. Check that the associated PLC data blocks are correctly sized and accessible. Re-download the project to the panel.
    Event ID: 5001
    Alarm system error — The alarm log could not be written due to insufficient storage space or a corrupted log file.
    Clear the alarm log on the panel or increase the allocated storage for alarm logging in the project settings. Re-download the project if the log file is corrupted.
    Event ID: 6020
    Project transfer error — Transfer of the HMI project to the target panel was interrupted or failed.
    Check the transfer connection (USB, Ethernet, or MPI). Ensure the panel is in Transfer mode. Verify that the WinCC flexible version matches the Runtime version on the panel.
    Event ID: 7005
    License error — No valid license found for WinCC flexible Runtime or Engineering software.
    Verify that the software license (6AV6381-2BJ08-0AH0) is correctly installed using the Automation License Manager. Check the license dongle or software license key.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC operator panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), Mobile Panel, and Multi Panel series. It also supports PC-based Runtime installations on standard industrial PCs.

    Which PLC families can communicate with projects created in WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs. Communication is possible via MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) depending on the panel and PLC hardware configuration.

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP, Vista, and Windows 7. It is not officially supported on Windows 10. For Windows 10 compatibility, Siemens recommends migrating to WinCC (TIA Portal).

    Can WinCC flexible 2008 projects be migrated to TIA Portal WinCC?

    Yes, Siemens provides a migration tool within TIA Portal that allows WinCC flexible 2008 projects to be imported and converted. Some manual rework may be required depending on the complexity of the project and the features used.

    Does this license include the Runtime software for the HMI panel?

    The 6AV6381-2BJ08-0AH0 is an engineering software license for the WinCC flexible 2008 configuration environment. Runtime licenses for the target HMI panels are separate and must be ordered individually based on the panel type and size.

    Troubleshooting

    WinCC flexible 2008 fails to install or reports a license error after installation

    Check the Automation License Manager to verify whether a valid license for 6AV6381-2BJ08-0AH0 is present and active. Confirm the license has not been transferred to another machine.

    Use the Siemens Automation License Manager to transfer or restore the license to the current engineering PC. If using a USB dongle, ensure it is properly connected and recognized by the operating system.

    Project transfer to the HMI panel fails or times out

    Verify the transfer connection type (Ethernet, USB, or MPI) and confirm the panel is set to Transfer mode. Check firewall settings on the engineering PC that may be blocking the transfer port.

    Disable Windows Firewall temporarily during transfer or add WinCC flexible as an exception. Ensure the correct IP address or MPI address is configured in the project transfer settings. Try a direct USB connection if network transfer fails.

    HMI panel shows communication errors or tags display question marks at Runtime

    Check the PLC connection parameters in the WinCC flexible project, including the PLC IP address or MPI address, rack, and slot number. Verify the physical communication link between the panel and PLC.

    Correct the connection parameters in the WinCC flexible engineering software and re-download the project. Confirm the PLC is powered and in RUN mode, and that the network cable or PROFIBUS connector is properly seated.

    Simulation mode does not start or crashes immediately

    Check that the correct WinCC flexible Runtime simulation component is installed. Verify that no other Runtime or simulation instance is already running in the background.

    Close all background instances of WinCC flexible Runtime via Task Manager, then restart the simulation. If the issue persists, repair the WinCC flexible installation using the original installation media.

    Alarm logging stops recording events on the panel

    Check the available storage space on the panel's internal memory or memory card. Review the alarm logging configuration in the project to confirm the log size and overwrite settings.

    Clear old alarm log entries from the panel or increase the maximum log size in the WinCC flexible project settings. If a memory card is used, verify it is properly inserted and not write-protected. Re-download the updated project to the panel.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart