• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2BJ08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2BJ08-0AV0 WinCC flexible 2008

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6381-2BJ08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2BJ08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This package is the full runtime and configuration environment used to develop, commission, and maintain HMI (Human-Machine Interface) applications for Siemens SIMATIC panels and compatible devices. It belongs to the broader SIMATIC HMI software portfolio and is designed for use on standard engineering PCs running Windows.

    WinCC flexible 2008 provides a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports a wide range of SIMATIC HMI hardware targets including the TP, OP, MP, and Mobile Panel series. It offers integration with SIMATIC STEP 7 for seamless PLC-HMI project coordination, and supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces. The 2008 edition introduced enhanced usability features, improved performance for large projects, and extended device support compared to earlier versions.

    WinCC flexible 2008 is used across a broad range of industrial sectors including manufacturing, automotive, food and beverage, chemical processing, and water treatment. It is particularly suited for machine builders and system integrators who need to develop standardized HMI solutions across multiple panel types from a single engineering environment. The software's scalability allows it to serve both small standalone machine applications and larger distributed plant visualization systems.

    Technical Specifications

    Software Version WinCC flexible 2008
    Software Type Engineering Software / HMI Configuration Tool
    License Type Full License
    Compatible Operating Systems Windows XP, Windows Vista, Windows 7 (32/64-bit)
    SIMATIC Integration STEP 7 integration supported
    Supported HMI Devices SIMATIC TP, OP, MP, Mobile Panel series
    Communication Protocols PROFIBUS, PROFINET, MPI, Ethernet
    Project Languages Up to 32 languages per project
    Alarm Management Supported (bit alarms, analog alarms)
    Recipe Management Supported
    Trend Display Supported
    Scripting VB Script supported
    Series/Product Family SIMATIC WinCC flexible

    Common Error Codes and Software Events

    Error 1920
    Service failed to start. The WinCC flexible runtime service could not be initialized during startup.
    Check that all required runtime components are correctly installed. Reinstall the software if components are missing or corrupted.
    Error 1722
    Windows Installer package error during installation. A program run as part of the setup did not finish as expected.
    Ensure the PC meets minimum system requirements. Run the installer as Administrator and disable antivirus software during installation.
    Runtime Communication Error
    The HMI runtime cannot establish a connection to the configured PLC or controller.
    Verify communication settings (IP address, MPI address, PROFIBUS address). Check physical cable connections and ensure the PLC is in RUN mode.
    License Error
    No valid license found for WinCC flexible 2008. The software is running in demo mode or has stopped functioning.
    Use the Siemens Automation License Manager (ALM) to verify and transfer the correct license key to the engineering PC.
    Compiler Error
    Project compilation failed due to inconsistent or missing tag references in the HMI project.
    Review the compiler output log, correct all invalid tag references, and ensure all linked PLC symbols are up to date.
    Device Incompatibility Warning
    The selected target HMI device is not supported by the installed version of WinCC flexible.
    Install the latest service pack or update for WinCC flexible 2008 to extend device support, or select a compatible target device.
    Transfer Error
    Project transfer to the target HMI panel failed or was interrupted.
    Check the transfer channel settings (Ethernet, USB, or MPI). Ensure the panel is in Transfer mode and that firewall settings are not blocking the connection.

    Frequently Asked Questions

    What HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP 177, TP 277, OP 277, MP 277, MP 377, and Mobile Panel 177/277 series, among others. Compatibility depends on the installed service pack version.

    Can WinCC flexible 2008 be integrated with SIMATIC STEP 7?

    Yes, WinCC flexible 2008 can be integrated directly into the SIMATIC Manager environment via STEP 7, allowing shared symbol tables and coordinated PLC-HMI project management.

    What operating systems are compatible with this software?

    WinCC flexible 2008 is compatible with Windows XP (SP3), Windows Vista, and Windows 7 in both 32-bit and 64-bit editions. It is not officially supported on Windows 10 or later without additional compatibility measures.

    Is a license required to run WinCC flexible 2008 in engineering mode?

    Yes, a valid software license managed through the Siemens Automation License Manager (ALM) is required for full engineering functionality. Without a license, the software operates in a restricted demo mode.

    Does WinCC flexible 2008 support multi-language projects?

    Yes, WinCC flexible 2008 supports up to 32 languages within a single project, allowing operators to switch display languages at runtime on the HMI panel.

    Troubleshooting

    Software fails to install on Windows 7 64-bit PC

    Check the Windows Event Viewer for installer error codes. Verify that .NET Framework and Visual C++ redistributable prerequisites are present.

    Install all prerequisite software components listed in the WinCC flexible 2008 release notes, run the installer with Administrator privileges, and temporarily disable User Account Control (UAC) during installation.

    License not recognized after installation

    Open the Siemens Automation License Manager (ALM) and check whether the license key is present and assigned to the local machine.

    Transfer the license from the original storage medium or USB dongle using ALM. If the license is missing or corrupted, contact Siemens support for license recovery.

    Project cannot be transferred to the HMI panel

    Verify the transfer channel configuration in the project settings. Check whether the panel is set to Transfer mode and confirm the network or USB connection is active.

    Correct the IP address or communication channel settings in the project, place the panel in Transfer mode via its Start Center, and retry the transfer. Check PC firewall rules if using Ethernet transfer.

    Runtime alarms are not displayed on the target panel

    Check the alarm configuration in the WinCC flexible project, including trigger tags, alarm classes, and display object settings on the relevant screens.

    Verify that the alarm view object is correctly placed on the screen, that alarm classes are enabled, and that the associated PLC tags are correctly mapped and communicating.

    WinCC flexible crashes or freezes when opening large projects

    Monitor PC RAM and CPU usage during project load. Large projects with many tags and screens require significant system resources.

    Ensure the engineering PC meets or exceeds the recommended hardware specifications (minimum 2 GB RAM, dual-core CPU). Close other applications during engineering work and consider splitting very large projects into smaller modules.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart